Difference between revisions of "Materials:(Villa) SS 100"

Jump to: navigation, search

Difference between revisions of "Materials:(Villa) SS 100"

 
(One intermediate revision by the same user not shown)
Line 25: Line 25:
  
 
====OVERVIEW====
 
====OVERVIEW====
The SS 100 standing seam panel is formed with an on-site/in-shop continuous metal roofing panel roll forming machine (New Tech Machinery Panel Machine). This machine produces a standing seam panel with a seam height 25.4 mm (1") and profiles can vary from 304.8 mm (12") wide up to 533.4 mm (21")wide.  This machine produces Seam Lock - SS 100 with a seam height of 25.mm (1") and Seam Lock - SS 150 with a seam height of 38.1 mm (1-1/2").
+
The SS 100 standing seam panel is formed with an on-site/in-shop continuous metal roofing panel roll forming machine (New Tech Machinery Panel Machine). This machine produces Seam Lock - SS 100 with a seam height of 25.4 mm (1"); profiles can vary from 304.8 mm (12") wide up to 533.4 mm (21") wide.  The machine also produces the SS 150 Seam Lock panel with a seam height of 38.1 mm (1-1/2").
  
 
On-site roll forming provides for the elimination of end lap with continuous panel forming capabilities in lengths up to nominal 46 m (150').
 
On-site roll forming provides for the elimination of end lap with continuous panel forming capabilities in lengths up to nominal 46 m (150').
Line 31: Line 31:
 
====SYSTEM DESCRIPTION====
 
====SYSTEM DESCRIPTION====
 
<ol>
 
<ol>
<li>'''General''': The SS100 panel is a standing seam concealed fastener roofing panel. The maximum spacing of the clip is 609.6 mm (24") on center.
+
<li>'''General''': The SS 100 panel is a standing seam concealed fastener roofing panel. The maximum spacing of the clip is 609.6 mm (24") on center.
 
<li>'''Range of application''': Installed on wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
 
<li>'''Range of application''': Installed on wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
 
<li>'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications.
 
<li>'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications.
Line 49: Line 49:
  
 
====SITE CONDITIONS====
 
====SITE CONDITIONS====
Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
+
Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
  
 
====PERFORMANCE REQUIREMENTS====
 
====PERFORMANCE REQUIREMENTS====

Latest revision as of 17:54, 5 November 2024



Division C - Accepted Materials


SS 100 (Mechanical Lock)
by Villa Roofing & Sheet Metal Ltd.

The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program.
Manufacturer
Villa Roofing & Sheet Metal Ltd.
Contact Address
See the current Membership list and contact information at www.rcabc.org
Product Group - Standing Seam Metal Roof System
Panel Machine
New Tech Machinery Panel Machine
Panel Name
SS 100
Seam Type
Mechanical Lock

The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer.

OVERVIEW

The SS 100 standing seam panel is formed with an on-site/in-shop continuous metal roofing panel roll forming machine (New Tech Machinery Panel Machine). This machine produces Seam Lock - SS 100 with a seam height of 25.4 mm (1"); profiles can vary from 304.8 mm (12") wide up to 533.4 mm (21") wide. The machine also produces the SS 150 Seam Lock panel with a seam height of 38.1 mm (1-1/2").

On-site roll forming provides for the elimination of end lap with continuous panel forming capabilities in lengths up to nominal 46 m (150').

SYSTEM DESCRIPTION

  1. General: The SS 100 panel is a standing seam concealed fastener roofing panel. The maximum spacing of the clip is 609.6 mm (24") on center.
  2. Range of application: Installed on wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
  3. Panel Attachment: Fastening is site specific, engineer must confirm fixing specifications.
  4. Fasteners (Screws):
    1. Fasteners used to attach panels to plywood to be No. 10-12 by 25 mm (1") long pancake head wood screws. Minimum two fasteners per clip to be used.
  5. Panel Clips: One-piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 609.6 mm (24") on center maximum, or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, Article 3.1.3.3. and Article 3.1.3.5.).
  6. Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.

PROFILE

N/A

TECHNICAL DATA SHEET

N/A

SITE CONDITIONS

Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").

PERFORMANCE REQUIREMENTS

  1. Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
  2. Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.


Back to Site-Formed Metal Roofing Systems

Back to Accepted Materials


Home