Difference between revisions of "Materials:(M. Kirk) Mechanical Seam SS200"

Jump to: navigation, search

Difference between revisions of "Materials:(M. Kirk) Mechanical Seam SS200"

(Created page with "::<big>This material has been accepted by the RGC, but this page is still under construction. Please come again</big> :::- RPM Manager")
 
Line 1: Line 1:
−
::<big>This material has been accepted by the RGC, but this page is still under construction.  Please come again</big>
+
__NOTOC__
 +
__NONUMBEREDHEADINGS__
 +
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
  
−
:::- RPM Manager
+
<big><big>Division C - Accepted Materials</big></big>
 +
<hr>
 +
<big><big><big><big><big>MK Mechanical Seam SS200</big></big></big></big></big><br>
 +
<big><big><big>by Mack Kirk Industries Ltd.</big></big></big><br>
 +
 
 +
{| class="wikitable"
 +
|-
 +
| style="background-color: #ffffcc; column-width:100%" | The metal panel listed and described below is accepted for use in the '''''RoofStar Guarantee Program'''''.
 +
|}
 +
{| class="wikitable"
 +
|-
 +
|
 +
;'''Manufacturer''': Mack Kirk Roofing & Sheet Metal Ltd.
 +
;Contact Address: See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org]
 +
;Product Group: Standing Seam Metal Roof System
 +
;Panel Machine: New Tech Machinery, Model SSH 2070216
 +
;Accepted for the ''RoofStar Guarantee Program'': October 23, 2026
 +
;Accepted for application in: Water-shedding Roof Systems
 +
;Panel Name: MK Mechanical Seam SS200
 +
;Seam Type: Mechanical Lock
 +
 
 +
The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.  For more information about this product or system, consult the manufacturer.
 +
|}
 +
 
 +
====OVERVIEW====
 +
The standing seam panel is formed with an on-site/in-shop continuous metal roofing panel roll forming New Tech Machinery SSQ2. This machine produces a standing seam panel with a seam height of 50.8 mm ( 2.0") and profiles can vary from 305mm (12") wide up to 610mm (24") wide.
 +
 
 +
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal m (95').
 +
 
 +
====SYSTEM DESCRIPTION====
 +
<ol>
 +
<li>'''General''': The MK Mechanical Seam SS200 metal panel is secured with concealed fastener.
 +
<li>'''Seam Height''': 50.8 mm (2")
 +
<li>'''Panel Widths''': 304.8 mm (12") wide up to 609.6 mm (24") wide
 +
<li>'''Maximum Length''': 29 m (95')
 +
<li>'''Range of Application''': Installed on wood or metal sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction.
 +
<li>'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications.
 +
<li>'''Fasteners (Screws)''': No. 10-16 , No. 2 Phillips head self-drilling point steel screws
 +
<ol>
 +
<li>Fasteners used to attach panel clips to steel - consult the panel manufacturer for details.
 +
<li>Fasteners used to attach panel clips to plywood - consult the panel manufacturer for details.
 +
</li></ol>
 +
<li>'''Panel Clips''': One piece assembly, manufactured by New Tech Machinery (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.3._Resistance_to_Specified_Wind_Loads  Article 3.1.3.3.] and [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.5._Submittals Article 3.1.3.5.]).
 +
<li>'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].
 +
</li></ol>
 +
 
 +
====PROFILE====
 +
N/A
 +
 
 +
====TECHNICAL DATA SHEET====
 +
Click below for the '''Technical Data Sheet'''
 +
 
 +
<div style="width:150px; text-align: left;">
 +
[[File:Pdf.png|75 px|link=https://rpm.rcabc.org/images/4/4c/MK_Mechanical_Seam_SS_200_Tech_Sheet.pdf |'''Technical Data Sheet''']]
 +
</div>
 +
 
 +
====SITE CONDITIONS====
 +
Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
 +
 
 +
====PERFORMANCE REQUIREMENTS====
 +
<ol>
 +
<li>'''Wind Uplift Resistance''': Panel securement shall conform to the requirements in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#PART_3 Part 3] of the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].
 +
<li>'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#Section_9.2._Materials Section 9.2.] of the Standard.
 +
</li></ol>
 +
 
 +
<hr>
 +
 
 +
 
 +
[[Architectural Metal Roofing|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Site-Formed Metal Roofing Systems'']]
 +
 
 +
[[Materials by Product Type|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Accepted Materials'']]
 +
 
 +
 
 +
[[Main Page|Home]]

Revision as of 19:10, 13 November 2026



Division C - Accepted Materials


MK Mechanical Seam SS200
by Mack Kirk Industries Ltd.

The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program.
Manufacturer
Mack Kirk Roofing & Sheet Metal Ltd.
Contact Address
See the current Membership list and contact information at www.rcabc.org
Product Group
Standing Seam Metal Roof System
Panel Machine
New Tech Machinery, Model SSH 2070216
Accepted for the RoofStar Guarantee Program
October 23, 2026
Accepted for application in
Water-shedding Roof Systems
Panel Name
MK Mechanical Seam SS200
Seam Type
Mechanical Lock

The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer.

OVERVIEW

The standing seam panel is formed with an on-site/in-shop continuous metal roofing panel roll forming New Tech Machinery SSQ2. This machine produces a standing seam panel with a seam height of 50.8 mm ( 2.0") and profiles can vary from 305mm (12") wide up to 610mm (24") wide.

On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal m (95').

SYSTEM DESCRIPTION

  1. General: The MK Mechanical Seam SS200 metal panel is secured with concealed fastener.
  2. Seam Height: 50.8 mm (2")
  3. Panel Widths: 304.8 mm (12") wide up to 609.6 mm (24") wide
  4. Maximum Length: 29 m (95')
  5. Range of Application: Installed on wood or metal sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction.
  6. Panel Attachment: Fastening is site specific, engineer must confirm fixing specifications.
  7. Fasteners (Screws): No. 10-16 , No. 2 Phillips head self-drilling point steel screws
    1. Fasteners used to attach panel clips to steel - consult the panel manufacturer for details.
    2. Fasteners used to attach panel clips to plywood - consult the panel manufacturer for details.
  8. Panel Clips: One piece assembly, manufactured by New Tech Machinery (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, Article 3.1.3.3. and Article 3.1.3.5.).
  9. Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.

PROFILE

N/A

TECHNICAL DATA SHEET

Click below for the Technical Data Sheet

Technical Data Sheet

SITE CONDITIONS

Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").

PERFORMANCE REQUIREMENTS

  1. Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
  2. Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.


Back to Site-Formed Metal Roofing Systems

Back to Accepted Materials


Home