Division C - Accepted Materials
MK Mechanical Seam SS200
by Mack Kirk Industries Ltd.
| The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program. |
The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. |
OVERVIEW
The standing seam panel is formed with an on-site/in-shop continuous metal roofing panel roll forming New Tech Machinery SSQ2. This machine produces a standing seam panel with a seam height of 50.8 mm ( 2.0") and profiles can vary from 305mm (12") wide up to 610mm (24") wide.
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal m (95').
SYSTEM DESCRIPTION
- General: The MK Mechanical Seam SS200 metal panel is secured with concealed fastener.
- Seam Height: 50.8 mm (2")
- Panel Widths: 304.8 mm (12") wide up to 609.6 mm (24") wide
- Maximum Length: 29 m (95')
- Range of Application: Installed on wood or metal sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction.
- Panel Attachment: Fastening is site specific, engineer must confirm fixing specifications.
- Fasteners (Screws): No. 10-16 , No. 2 Phillips head self-drilling point steel screws
- Fasteners used to attach panel clips to steel - consult the panel manufacturer for details.
- Fasteners used to attach panel clips to plywood - consult the panel manufacturer for details.
- Panel Clips: One piece assembly, manufactured by New Tech Machinery (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, Article 3.1.3.3. and Article 3.1.3.5.).
- Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.
PROFILE
| MK Mechanical Seam SS200 Metal Panel |
|---|
TECHNICAL DATA SHEET
Click below for the Technical Data Sheet
SITE CONDITIONS
Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
PERFORMANCE REQUIREMENTS
- Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
- Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.