Line 14: Line 14:
 
|-
 
|-
 
|  
 
|  
;'''Manufacturer''': (Active Member Name here)
+
;'''Manufacturer''': Ridgeline Exteriors Inc.
 
;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org]
 
;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org]
 
;'''Product Group - Standing Seam Metal Roof System'''
 
;'''Product Group - Standing Seam Metal Roof System'''
;'''Panel Machine''': Machine Name (Model number)
+
;'''Panel Machine''': New Tech Machinery Panel Machine
;'''Panel Name''': Name
+
;'''Panel Name''': SS 150
;'''Seam Type''': Mechanical Lock/Snap-Lock/Flange-fastened
+
;'''Seam Type''': Mechanical Lock
  
 
The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.  For more information about this product or system, consult the manufacturer.
 
The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.  For more information about this product or system, consult the manufacturer.
Line 25: Line 25:
  
 
====OVERVIEW====
 
====OVERVIEW====
(The following overview is boilerplate wording and can be modified to suit the specific panel description.
+
The SS 150 metal panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine (New Tech Machinery Panel Machine). This machine produces a standing seam panel with a seam height of 38 mm (1-1/2") and profiles can vary from 300 mm (12") wide up to 500 mm (20") wide.
The (panel name) metal panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine (Machine name). This machine produces a standing seam panel with a seam height of XXX mm (XX") and profiles can vary from XXX mm (XX") wide up to XXX mm (XX") wide.
 
  
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to XXX'.
+
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities.  For available panel lengths, consult the manufacturer.
  
 
====SYSTEM DESCRIPTION====
 
====SYSTEM DESCRIPTION====
 
<ol>
 
<ol>
<li>'''General''': The (panel name) metal panel is secured with concealed fastener.
+
<li>'''General''': Standing seam panels use a hidden fastening clip system for mechanical fastening to a solid substrate. The maximum spacing of the clips is 600 mm (24") on centre. The panels are locked together, with the clips as part of the seam, by use of a mechanical seamer.
<li>'''Range of application''': Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction.
+
<li>'''Range of application''': On wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
 
<li>'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications.
 
<li>'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications.
 
<li>'''Fasteners (Screws)''':  
 
<li>'''Fasteners (Screws)''':  
 
<ol>
 
<ol>
<li>Fasteners used to attach panel clips to steel must be No. XX-XX by XX mm (X") long self-drilling, (screw type - i.e., self-tapping pancake head plated steel) screws.  Use (i.e., two fasteners per panel clip), inserted into panel clip guide holes.
+
<li>Fasteners used to attach panel clips to plywood must be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used.
<li>Fasteners used to attach panel clips to plywood must be No. XX-XX by XX mm (X") long (screw type - i.e., self-tapping pancake head plated steel) screws for wood. Use (i.e., two fasteners per panel clip), inserted into panel clip guide holes.
 
 
</li></ol>
 
</li></ol>
<li>'''Panel Clips''': One piece assembly XX mm (X") wide, XX mm (X") high, manufactured by (name of panel manufacturer) (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.3._Resistance_to_Specified_Wind_Loads  Article 3.1.3.3.] and [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.5._Submittals Article 3.1.3.5.]).
+
<li>'''Panel Clips''': One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high (Englert “Series 1000 Interlocking Clip”). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced 600 mm (24") on centre fastened to plywood deck. Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.3._Resistance_to_Specified_Wind_Loads  Article 3.1.3.3.] and [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.5._Submittals Article 3.1.3.5.]).
 
<li>'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].
 
<li>'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].
 
</li></ol>
 
</li></ol>
  
 
====PROFILE====
 
====PROFILE====
N/A
+
{| class="wikitable"
 +
|-
 +
! 1-1/2" Single Lock
 +
|-
 +
| [[File:Ridgeline SS 150 Panel Profile.png|frameless|link=https://rpm.rcabc.org/images/e/e1/Ridgeline_SS_150_Panel_Profile.png|750px]]
 +
|}
  
 
====TECHNICAL DATA SHEET====
 
====TECHNICAL DATA SHEET====
N/A
+
Click below for the '''Technical Data Sheet'''
 +
 
 +
<div class="col-md-12">
 +
<div class="col-md-1">
 +
<div style="text-align: center;">
 +
[[File:Pdf.png|75 px|link=https://rpm.rcabc.org/images/b/b6/Ridgeline_SS_150_Panel_TDS.pdf|'''Technical Data Sheet''']]
 +
Panel TDS
 +
</div>
 +
</div>
 +
</div>
 +
<div class="col-md-12">
 +
</div>
  
 
====SITE CONDITIONS====
 
====SITE CONDITIONS====
Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
+
Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:4 (3" in 12").
  
 
====PERFORMANCE REQUIREMENTS====
 
====PERFORMANCE REQUIREMENTS====

Revision as of 19:55, 4 November 2024



Division C - Accepted Materials


SS 150 (Snap Lock)
by Ridgeline Exteriors Inc.

The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program.
Manufacturer
Ridgeline Exteriors Inc.
Contact Address
See the current Membership list and contact information at www.rcabc.org
Product Group - Standing Seam Metal Roof System
Panel Machine
New Tech Machinery Panel Machine
Panel Name
SS 150
Seam Type
Mechanical Lock

The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer.

OVERVIEW

The SS 150 metal panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine (New Tech Machinery Panel Machine). This machine produces a standing seam panel with a seam height of 38 mm (1-1/2") and profiles can vary from 300 mm (12") wide up to 500 mm (20") wide.

On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities. For available panel lengths, consult the manufacturer.

SYSTEM DESCRIPTION

  1. General: Standing seam panels use a hidden fastening clip system for mechanical fastening to a solid substrate. The maximum spacing of the clips is 600 mm (24") on centre. The panels are locked together, with the clips as part of the seam, by use of a mechanical seamer.
  2. Range of application: On wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
  3. Panel Attachment: Fastening is site specific, engineer must confirm fixing specifications.
  4. Fasteners (Screws):
    1. Fasteners used to attach panel clips to plywood must be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used.
  5. Panel Clips: One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high (Englert “Series 1000 Interlocking Clip”). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced 600 mm (24") on centre fastened to plywood deck. Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, Article 3.1.3.3. and Article 3.1.3.5.).
  6. Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.

PROFILE

1-1/2" Single Lock
Ridgeline SS 150 Panel Profile.png

TECHNICAL DATA SHEET

Click below for the Technical Data Sheet

Technical Data Sheet Panel TDS

SITE CONDITIONS

Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:4 (3" in 12").

PERFORMANCE REQUIREMENTS

  1. Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
  2. Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.