Materials:Ridgeline SS 150
Materials:Ridgeline SS 150
Division C - Accepted Materials
SS 150 (Snap Lock)
by Ridgeline Exteriors Inc.
The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program. |
The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. |
OVERVIEW
The SS 150 metal panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine (New Tech Machinery Panel Machine). This machine produces a standing seam panel with a seam height of 38 mm (1-1/2") and profiles can vary from 300 mm (12") wide up to 500 mm (20") wide.
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities. For available panel lengths, consult the manufacturer.
SYSTEM DESCRIPTION
- General: Standing seam panels use a hidden fastening clip system for mechanical fastening to a solid substrate. The maximum spacing of the clips is 600 mm (24") on centre. The panels are locked together, with the clips as part of the seam, by use of a mechanical seamer.
- Range of application: On wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
- Panel Attachment: Fastening is site specific, engineer must confirm fixing specifications.
- Fasteners (Screws):
- Fasteners used to attach panel clips to plywood must be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used.
- Panel Clips: One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high (Englert “Series 1000 Interlocking Clip”). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced 600 mm (24") on centre fastened to plywood deck. Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, Article 3.1.3.3. and Article 3.1.3.5.).
- Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.
PROFILE
1-1/2" Single Lock |
---|
TECHNICAL DATA SHEET
Click below for the Technical Data Sheet
SITE CONDITIONS
Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:4 (3" in 12").
PERFORMANCE REQUIREMENTS
- Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
- Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.