Materials:(M. Kirk) Mechanical Seam SS200

Jump to: navigation, search

Materials:(M. Kirk) Mechanical Seam SS200

Revision as of 18:33, 24 November 2026 by James Klassen (talk | contribs) (James Klassen moved page Materials:(M. Kirk) MK Mechanical Seam SS200 to Materials:(M. Kirk) Mechanical Seam SS200)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)



Division C - Accepted Materials


MK Mechanical Seam SS200
by Mack Kirk Industries Ltd.

The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program.
Manufacturer
Mack Kirk Roofing & Sheet Metal Ltd.
Contact Address
See the current Membership list and contact information at www.rcabc.org
Product Group
Standing Seam Metal Roof System
Panel Machine
New Tech Machinery, Model SSH 2070216
Accepted for the RoofStar Guarantee Program
October 23, 2026
Accepted for application in
Water-shedding Roof Systems
Panel Name
MK Mechanical Seam SS200
Seam Type
Mechanical Lock

The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer.

OVERVIEW

The standing seam panel is formed with an on-site/in-shop continuous metal roofing panel roll forming New Tech Machinery SSQ2. This machine produces a standing seam panel with a seam height of 50.8 mm ( 2.0") and profiles can vary from 305mm (12") wide up to 610mm (24") wide.

On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal m (95').

SYSTEM DESCRIPTION

  1. General: The MK Mechanical Seam SS200 metal panel is secured with concealed fastener.
  2. Seam Height: 50.8 mm (2")
  3. Panel Widths: 304.8 mm (12") wide up to 609.6 mm (24") wide
  4. Maximum Length: 29 m (95')
  5. Range of Application: Installed on wood or metal sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction.
  6. Panel Attachment: Fastening is site specific, engineer must confirm fixing specifications.
  7. Fasteners (Screws): No. 10-16 , No. 2 Phillips head self-drilling point steel screws
    1. Fasteners used to attach panel clips to steel - consult the panel manufacturer for details.
    2. Fasteners used to attach panel clips to plywood - consult the panel manufacturer for details.
  8. Panel Clips: One piece assembly, manufactured by New Tech Machinery (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, Article 3.1.3.3. and Article 3.1.3.5.).
  9. Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.

PROFILE

MK Mechanical Seam SS200 Metal Panel
MK Mechanical Seam SS200 (Profile).png

TECHNICAL DATA SHEET

Click below for the Technical Data Sheet

Technical Data Sheet

SITE CONDITIONS

Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").

PERFORMANCE REQUIREMENTS

  1. Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
  2. Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.


Back to Site-Formed Metal Roofing Systems

Back to Accepted Materials


Home