Difference between revisions of "Template:PARS Membrane - SBS 2-Ply Cap"
Difference between revisions of "Template:PARS Membrane - SBS 2-Ply Cap"
Line 4: | Line 4: | ||
|+ How to use the table: | |+ How to use the table: | ||
− | #In the table below look for | + | #In the table below look for <u>maximum wind uplift values that exceed</u> the requirements determined through the RCI calculator;<p>('''NOTE''': while the reports show two different values for tested maximum assembly strength, the RPM tables display only the values adjusted for the required safety factor of 1.5)</p> |
#Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report. It will break down the assembly by its components. Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the '''''RoofStar Guarantee Program''''' (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer); | #Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report. It will break down the assembly by its components. Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the '''''RoofStar Guarantee Program''''' (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer); | ||
#In cases where a tested Secondary material is not accepted by the '''''RoofStar Guarantee Program''''', look for alternates which often are published in the each report. In the absence of published alternates, locate a possible alternate in the [http://rpm.rcabc.org/index.php?title=Materials_by_Product_Type '''Accepted Materials'''] section of this Manual. If you are unsure about compatibility, contact the [mailto:guarantees@rcabc.org '''RCABC''']. | #In cases where a tested Secondary material is not accepted by the '''''RoofStar Guarantee Program''''', look for alternates which often are published in the each report. In the absence of published alternates, locate a possible alternate in the [http://rpm.rcabc.org/index.php?title=Materials_by_Product_Type '''Accepted Materials'''] section of this Manual. If you are unsure about compatibility, contact the [mailto:guarantees@rcabc.org '''RCABC''']. |
Revision as of 20:06, 18 July 2017
Manufacturer | Product Name | Number of Tested Systems (per report) |
kPa (Low) | kPa (High) | Psf (Low) | Psf (High) | Deck Type | Downloadable Test Report | Test Facility | Test Facility Report No. |
---|---|---|---|---|---|---|---|---|---|---|
Firestone Building Products | SBS Torch | 1 Tested System | ---- | -2.10 | ---- | -45.00 | Steel | PARS Test Report 1 | exp. Service Inc. | PUB-DRU281261 |
Firestone Building Products | SBS FR Torch | 1 Tested System | ---- | -2.10 | ---- | -45.00 | Steel | PARS Test Report 1 | exp. Service Inc. | PUB-DRU281261 |
Firestone Building Products | SBS Premium | 1 Tested System | ---- | -2.10 | ---- | -45.00 | Steel | PARS Test Report 1 | exp. Service Inc. | PUB-DRU281261 |
Firestone Building Products | SBS Premium FR Torch | 1 Tested System | ---- | -2.10 | ---- | -45.00 | Steel | PARS Test Report 1 | exp. Service Inc. | PUB-DRU281261 |
Siplast | Paradiene 30 TG | 1 Tested System 1 Tested System 1 Tested System 1 Tested System 1 Tested System |
---- ---- ---- ---- ---- |
-1.90 -1.80 -2.86 -2.90 -1.46 |
---- ---- ---- ---- ---- |
-40.00 -37.00 -60.00 -60.00 -30.00 |
Steel Steel Steel Steel Steel |
PARS Test Report 1 PARS Test Report 6 PARS Test Report 7 PARS Test Report 8 PARS Test Report 9 |
Intertek exp. Service Inc. exp. Service Inc. exp. Service Inc. exp. Service Inc. |
E9988.01-109-44 SIPZ-DRS-00221706-02-5100 SIPZ-DRS-00221706-01-5100 SIPZ-DRS-00215482-01-5100 SIPZ-DRS-00221706-03-5100 |
Siplast | Paradiene 30 | 1 Tested System 1 Tested System 1 Tested System 1 Tested System |
---- ---- ---- ---- |
-1.40 -2.30 -3.35 -2.87 |
---- ---- ---- ---- |
-30.00 -46.67 -70.00 -60.00 |
Plywood Steel Steel Steel |
PARS Test Report 2 PARS Test Report 3 PARS Test Report 4 PARS Test Report 5 |
Intertek | E9988.02-109-44 E9988.03-109-44 E9988.05-109-44 E9988.06-109-44 |
Soprema Inc. | Sopralene Stick HR GR | 2 Tested Systems | -1.80 | -3.00 | -37.00 | -62.00 | Plywood | PARS Test Report 4 | exp. Service Inc. | PUB-DRC303967 |
Soprema Inc. | Soprafix Traffic Cap 660 | 3 Tested Systems | -1.40 | -2.80 | -30.00 | -58.00 | Steel | PARS Test Report 1 | exp. Service Inc. | PUB-DRU305544 |
Soprema Inc. | Soprafix Traffic Cap FR 661 | 3 Tested Systems | -1.40 | -2.80 | -30.00 | -58.00 | Steel | PARS Test Report 1 | exp. Service Inc. | PUB-DRU305544 |
Soprema Inc. | Sopralene Flam 180 GR | 3 Tested Systems 1 Tested System 4 Tested Systems 3 Tested Systems |
-1.40 ---- -1.40 -2.10 |
-2.80 -2.90 -3.40 -5.00 |
-30.00 ---- -30.00 -45.00 |
-58.00 -60.00 -70.00 -105.00 |
Steel Steel Steel Steel |
PARS Test Report 1 PARS Test Report 2 PARS Test Report 3 PARS Test Report 5 |
exp. Service Inc. | PUB-DRU305544 PUB-DRU293332 PUB-DRU304337 PUB-DRU293389 |
Soprema Inc. | Sopralene Flam 250 GR | 3 Tested Systems 1 Tested System 4 Tested Systems 3 Tested Systems |
-1.40 ---- -1.40 -2.10 |
-2.80 -2.90 -3.40 -5.00 |
-30.00 ---- -30.00 -45.00 |
-58.00 -60.00 -70.00 -105.00 -117.00 |
Steel Steel Steel Steel Steel |
PARS Test Report 1 PARS Test Report 2 PARS Test Report 3 PARS Test Report 5 PARS Test Report 6 |
exp. Service Inc. | PUB-DRU305544 PUB-DRU293332 PUB-DRU304337 PUB-DRU293389 SOPI-DRS-00231265-08-5100 |
Soprema Inc. | Sopralene Mammouth GR | 3 Tested Systems 1 Tested System 4 Tested Systems 3 Tested Systems |
-1.40 ---- -1.40 -2.10 |
-2.80 -2.90 -3.40 -5.00 |
-30.00 ---- -30.00 -45.00 |
-58.00 -60.00 -70.00 -105.00 |
Steel Steel Steel Steel |
PARS Test Report 1 PARS Test Report 2 PARS Test Report 3 PARS Test Report 5 |
exp. Service Inc. | PUB-DRU305544 PUB-DRU293332 PUB-DRU304337 PUB-DRU293389 |
Soprema Inc. | Sopraply Traffic Cap 560 | 3 Tested Systems 1 Tested System 4 Tested Systems 3 Tested Systems |
-1.40 ---- -1.40 -2.10 |
-2.80 -2.90 -3.40 -5.00 |
-30.00 ---- -30.00 -45.00 |
-58.00 -60.00 -70.00 -105.00 |
Steel Steel Steel Steel |
PARS Test Report 1 PARS Test Report 2 PARS Test Report 3 PARS Test Report 5 |
exp. Service Inc. | PUB-DRU305544 PUB-DRU293332 PUB-DRU304337 PUB-DRU293389 |
Soprema Inc. | Sopraply Traffic Cap FR 561 | 3 Tested Systems 1 Tested System 4 Tested Systems 3 Tested Systems |
-1.40 ---- -1.40 -2.10 |
-2.80 -2.90 -3.40 -5.00 |
-30.00 ---- -30.00 -45.00 |
-58.00 -60.00 -70.00 -105.00 |
Steel Steel Steel Steel |
PARS Test Report 1 PARS Test Report 2 PARS Test Report 3 PARS Test Report 5 |
exp. Service Inc. | PUB-DRU305544 PUB-DRU293332 PUB-DRU304337 PUB-DRU293389 |
Soprema Inc. | SopraStar Flam HD GR | 3 Tested Systems 1 Tested System 4 Tested Systems 3 Tested Systems |
-1.40 ---- -1.40 -2.10 |
-2.80 -2.90 -3.40 -5.00 |
-30.00 ---- -30.00 -45.00 |
-58.00 -60.00 -70.00 -105.00 |
Steel Steel Steel Steel |
PARS Test Report 1 PARS Test Report 2 PARS Test Report 3 PARS Test Report 5 |
exp. Service Inc. | PUB-DRU305544 PUB-DRU293332 PUB-DRU304337 PUB-DRU293389 |