Difference between revisions of "Materials:(Bothwell-Accurate) BA-Versaclip (SS 675)"

Jump to: navigation, search

Difference between revisions of "Materials:(Bothwell-Accurate) BA-Versaclip (SS 675)"

(PROFILE)
(PERFORMANCE REQUIREMENTS)
Line 46: Line 46:
 
====PERFORMANCE REQUIREMENTS====
 
====PERFORMANCE REQUIREMENTS====
 
#'''Wind Uplift Standards''': Engineered designs to resist wind uplift may refer to the British Columbia Building Code, Div. B, Appendix C, Table C-2 which lists various types of loads, including wind loads, for specific reference locations throughout the province. See also [http://{{SERVERNAME}}/index.php?title=ASM_Application_Guides_and_Notes Guides and Notes (Wind Resistance)] for a simplified calculation procedure. Regardless of the resources indicated here, the Design Authority is responsible to perform accurate wind load calculations and specify securement requirements.
 
#'''Wind Uplift Standards''': Engineered designs to resist wind uplift may refer to the British Columbia Building Code, Div. B, Appendix C, Table C-2 which lists various types of loads, including wind loads, for specific reference locations throughout the province. See also [http://{{SERVERNAME}}/index.php?title=ASM_Application_Guides_and_Notes Guides and Notes (Wind Resistance)] for a simplified calculation procedure. Regardless of the resources indicated here, the Design Authority is responsible to perform accurate wind load calculations and specify securement requirements.
#'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the standards published in the [http://rpm.rcabc.org/index.php/Main_PageASM_(Architectural_Sheet_Metal)_Roof_Assemblies Architectural Sheet Metal (ASM) Roof Standards].
+
#'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the standards published in the [http://rpm.rcabc.org/index.php/RoofStar_Guarantee_Standards_for_ASM_Roof_Assemblies Architectural Sheet Metal (ASM) Roof Standards].
  
 
<hr>
 
<hr>

Revision as of 16:21, 24 September 2018


The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program.
Manufacturer
Bothwell-Accurate Company (B.C.) Ltd.
Contact Address
See the current Membership list and contact information at www.rcabc.org
Product Group - Standing Seam Metal Roof System
BA-Versaclip (SS 675)

The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer.

OVERVIEW

The BA-Versaclip (SS675) standing seam panel is formed with an on-site/in-shop continuous metal roofing panel roll forming machine (New Tech SS Multipro). This machine produces a standing seam panel with a seam height of 44.5mm (1.75") and profiles can vary from 304.8mm (12") wide up to 457.2mm (18") wide. This machine also produces FF100 (BA-Versasnap), SS100 (BA-Versaspan1), SS150 (BA-Versaspan1.5)

On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to 200' plus (depending on coil size and handling/maneuvering.

SYSTEM DESCRIPTION

  1. General: The BA-Versaclip (SS675) is a standing seam concealed fastener roof panel. The panel is attached with clips to allow for expansion and contraction. The maximum spacing of the clips and fasteners are 76.2mm (3').
  2. Range of application: Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction. BA-Versaclip has the greatest structural properties compared BA-Versasnap (FF100), BA-Versaspan1 (SS100), BA-Versaspan1.5 (SS150).
  3. Panel Attachment: Fasteners are fixed through clips that hook onto the male leg of the panel. Spacing is site specific, engineer must confirm fixing specifications.
  • Fasteners (Screws): Fasteners used to attach panel clips to steel to be No. 10-16 by 25 mm (1") long cadmium plated pancake head No. 2 Phillips drive, No. 3 self-drilling point steel screws. Two screws per clip inserted through 6.25 mm (1/4") diameter guide holes.
  • Roof Deck Fasteners (Panel Clips): One piece assembly, No. 22 MSG min thick, 87.5 mm (3-1/2") wide, 47.6 mm (1-7/8 in.) high. One panel clip spaced at 600 mm (24") on centre for Class 90.

PROFILE

BA-Versaclip (SS 675) Standing Seam Panel
BA-Versaclip (SS 675) Panel.jpg

TECHNICAL DATA SHEET

Click below for the Technical Data Sheet

Technical Data Sheet

SITE CONDITIONS

PERFORMANCE REQUIREMENTS

  1. Wind Uplift Standards: Engineered designs to resist wind uplift may refer to the British Columbia Building Code, Div. B, Appendix C, Table C-2 which lists various types of loads, including wind loads, for specific reference locations throughout the province. See also Guides and Notes (Wind Resistance) for a simplified calculation procedure. Regardless of the resources indicated here, the Design Authority is responsible to perform accurate wind load calculations and specify securement requirements.
  2. Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the standards published in the Architectural Sheet Metal (ASM) Roof Standards.