Architectural Metal Roofing

Jump to: navigation, search

Architectural Metal Roofing

Accepted Materials for a RoofStar Guarantee

The tables and products shown below provide basic material data and links to more information about the materials, including manufacturers' published Technical Data sheets, but this information is not intended for use as a comparison of material performance or quality. It is the sole responsibility of the Design Authority to assess the performance capability and material suitability for specific design requirements.

The materials listed are those which have been accepted by the RoofStar Guarantee Program (RCABC Guarantee Corp., or RGC) for use in a roof or grade-level waterproofing system that will qualify for a RoofStar Guarantee. The acceptance of these materials by the RGC (RoofStar Guarantee Program) in no way reflects on the quality or performance of other materials not listed.

The materials and guideline specifications are listed under the name of the manufacturer and/or supplier of the primary membrane material, with the exception of BUR membranes for which the reader will find RoofStar Guarantee Program guidelines on traditional built-up roofing systems (BUR) incorporating organic and glass felt primary membranes.

1 Site-Formed Metal Roof Systems (RCABC Active Members)

Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program
*ML = Mechanical Lock; SL = Snap Lock; NS (SL) = Nail Strip with Snap Lock; SC = Snap Cap
Manufacturer Product Name Profiles
(Click on image
to expand)
Seam Heights
mm (in.)
Seam Lock Type* Min. Panel Width
mm (in.)
Max. Panel Width
mm (in.)
Stiffeners Max. Panel Length
m (ft)
Admiral Roofing Ltd. AR9150 38.1 (1-1/2) ML 203.2 (8) 652.5 (26-1/2) 46 (150)
Admiral Roofing Ltd. AR5150 38.1 (1-1/2) SL 203.2 (8) 508 (20) 46 (150)
Admiral Roofing Ltd. AR5150 38.1 (1-1/2) NS (SL) 203.2 (8) 637.5 (25-1/2) 46 (150)
Alpha Roofing & Cladding Inc. Schlebach Quadro 25.4, 38.1, 50.8 (1, 1-1/2, 2) ML, SL, NS (SL) 228.6 (9) 508 (20) 46 (150)
Alpha Roofing & Cladding Inc. Knudson P-2401 50.8 (2) ML 304.8 (12) 508 (20) 46 (150)
Aurora Roofing Ltd. Knudson KR-12 38.1 (1-1/2) ML 304.8 (12) 508 (20) 46 (150)
Bothwell-Accurate Company (B.C.) Ltd. BA-Versaclip (SS 675) BA-Versaclip (SS 675) Panel 44.45 (1-3/4) ML 304.8 (12) 457.2 (18) Optional 61.5 (200)
Bothwell-Accurate Company (B.C.) Ltd. BA-Versaspan 100 (SS 100) BA-Versaspan 1 Profile 25.4 (1) SL 304.8 (12) 533.4 (21) Optional 61.5 (200)
Bothwell-Accurate Company (B.C.) Ltd. BA-Versaspan 150 (SS 150) BA-Versaspan 150 (SS 150) Panel.jpg 38.1 (1-1/2) ML 304.8 (12) 508 (20) Optional 61.5 (200)
Bothwell-Accurate Company (B.C.) Ltd. BA-Versaspan 200 (SS 200) BA-Versaspan 2 (SS 200) Panel 50.8 (2) ML 304.8 (12) 457.2 (18) Optional 61.5 (200)+
Bothwell-Accurate Company (B.C.) Ltd. BA-Versasnap (FF 100) BA-Versasnap FF 100 Panel.jpg 22.23 (7/8) SL 304.8 (12) 508 (20) Optional None stated
Cascade Roofing & Exteriors Inc. Zimmerman SS1500 38.1 (1-1/2) ML 304.8 (12) 508 (20) 24 (50)
Cascade Roofing & Exteriors Inc. Nu-Tech Snap-Loc 44.45 (1-3/4) SL 304.8 (12) 457.2 (18) Optional 46 (150)
D.M. Henderson Roofing Ltd. Zimmerman SS1500 38.1 (1-1/2) ML 304.8 (12) 508 (20) 46 (150)
Eby & Sons Construction Ltd. Zimmerman SS1500 38.1 (1-1/2) ML 304.8 (12) 508 (20) 46 (150)
Flynn Canada Ltd. Knudson KR-12 38.1 (1-1/2) ML 304.8 (12) 508 (20) 46 (150)
Flynn Canada Ltd. Knudson KR-24 38.1 (1-1/2) ML 304.8 (12) 508 (20) 46 (150)
Flynn Canada Ltd. Knudson P-2406 38.1 (1-1/2) ML 304.8 (12) 508 (20) N/A
Flynn Canada Ltd. Snap Lock II 675 44.45 (1-3/4) ML 304.8 (12) 508 (20) 46 (150)
Flynn Canada Ltd. SS 100 25.4 (1) ML 304.8 (12) 508 (20) 46 (150)
Flynn Canada Ltd. SS 150 38.1 (1-1/2) ML 304.8 (12) 508 (20) 46 (150)
Flynn Canada Ltd. SS100 Snap Seam 25.4 (1) SL 228.6 (9) 406.4 (16) 46 (150)
Flynn Canada Ltd. SS150 Snap Seam 38.1 (1-1/2) SL 228.6 (9) 406.4 (16) 46 (150)
G&G Roofing Ltd. Knudson KR-21 VP Varipan 38.1 (1-1/2) ML 304.8 (12) 508 (20) Optional 92 (300)
G&G Roofing Ltd. New Tech Machinery SSQ II 38.1 (1-1/2), 50.8 (2) ML, SL 304.8 (12) 508 (20) Optional 92 (300)
Heritage Roofing and Sheet Metal Ltd. Heritage 1/-1/2" Single Lock Heritage Roofing 1.5 Inch Single Lock Profile (Image).png 38.1 (1-1/2) ML 228.6 (9) 609.6 (24) Call Member for info.
Homan Roofing Ltd. SS 100 25.4 (1) ML 304.8 (12) 508 (20) 46 (150)
Homan Roofing Ltd. SS 150 38.1 (1-1/2) ML 304.8 (12) 508 (20) 46 (150)
Interior Roofing (2011) Ltd. Series 1000 38.1 (1-1/2) ML 203.2 (8) 508 (20) 46 (150)
Kelowna Roofing (1984) Ltd. Knudson P-2401 50.8 (2) ML 304.8 (12) 508 (20) 46 (150)
Laing Roofing Ltd. Quadro Snap Seam 38.1 (1-1/2) ML, SL, NS (SL) 228.6 (9) 508 (20) 46 (150)
Laing Roofing Ltd. Quadro Mechanical Lock Seam (Laing) Quadro Mechanical Lock Seam Profile.JPG 25.4 (1), 38.1 (1-1/2) ML 304.8 (12) 406.4 (16) Optional 47.2 (155)
Lam Metal Contracting Ltd. ESE 100 25.4 (1) ML 330.2 (13) 533 (21) Optional None stated
Lam Metal Contracting Ltd. Snap-Loc 25.4 (1) SL 304.8 (12) 508 (20) Standard None stated
Lam Metal Contracting Ltd. Berridge T-Panel 25.4 (1) SC 323.9 (12-3/4) 324 (12-3/4) Standard None stated
Lam Metal Contracting Ltd. Nu-Tech Snap-Loc 44.45 (1-3/4) SL 304.8 (12) 457.2 (18) Optional 46 (150)
Lam Metal Contracting Ltd. Schlebach 1" Lam Metals SS 150 profile.png 25.4 (1) ML 304.8 (12) 508 (20) Optional None stated
Lam Metal Contracting Ltd. SS 150 (38 mm) 1-1/2" SS 200 Standing Seam 38.1 (1-1/2) ML 304.8 (12) 609.6 (24) Optional None stated
Lam Metal Contracting Ltd. SS 200 (50 mm) 2" SS 200 Standing Seam 50.8 (2) ML 304.8 (12) 609.6 (24) None None stated
Lam Metal Contracting Ltd. Super Snap-Loc 25.4 (1) SL 304.8 (12) 508 (20) None stated
Langley Roofing Co. Ltd. SSQ675 SSQ675 Snap-Lock Panel 45.2 (1-3/4) SL 304.8 (12) 609.6 (24) Optional 46 (150)
Mack Kirk Roofing & Sheet Metal Ltd. MK Mechanical Lock - - - - -
Mack Kirk Roofing & Sheet Metal Ltd. MK Snap-Lock - - - - -
Mainline Roofing Co. Ltd. ESE 150 38.1 (1-1/2) ML 304.8 (12) 508 (20) 30.77 (100)
Marine Roofing (1996) Ltd. Nu-Tech Snap-Loc 44.45 (1-3/4) SL 304.8 (12) 457.2 (18) 46 (150)
Marine Roofing (1996) Ltd. MR-100 25.4 (1) SL 304.8 (12) 508 (20) 46 (150)
Marine Roofing (1996) Ltd. MR/S-100 25.4 (1) ML 304.8 (12) 508 (20) 46 (150)
Marine Roofing (1996) Ltd. MR/S-150 38.1 (1-1/2) ML 304.8 (12) 508 (20) 46 (150)
Marine Roofing (1996) Ltd. MR/S-200 Marine MRS-200 Profile 50.8 (2) ML 304.8 (12) 610 (24) Optional 46 (150)
Marine Roofing (1996) Ltd. MR-675 44.45 (1-3/4) SL 304.8 (12) 457.2 (18) 46 (150)
Metro Roofing & Sheet Metal Ltd. SS 100 25.4 (1) ML 304.8 (12) 508 (20) 46 (150)
Metro Roofing & Sheet Metal Ltd. SS 150 38.1 (1-1/2) ML 304.8 (12) 508 (20) 46 (150)
Metro Roofing & Sheet Metal Ltd. SS675 44.45 (1-3/4) ML 304.8 (12) 508 (20) 46 (150)
Nelson Roofing & Sheet Metal Ltd. SS 100 25.4 (1) ML 304.8 (12) 508 (20) 46 (150)
Nelson Roofing & Sheet Metal Ltd. SS 150 38.1 (1-1/2) ML 304.8 (12) 508 (20) 46 (150)
Nielsen Roofing & Sheet Metal Ltd. FF 100 Nielsen FF 100 Profile 25.4 (1) SL 304.8 (12) 609.6 (24) Optional 46 (150)
Nielsen Roofing & Sheet Metal Ltd. SS 100 Nielsen SS 100 Profile 23.4 (15/16) ML 304.8 (12) 609.6 (24) Optional 46 (150)
Parker Johnston Industries Ltd. Schlebach Quadro Plus 30/80 LM Parker J. Schlebach Quadro Profile 25.4 (1) ML 304.8 (12) 508 (20) None stated
Parker Johnston Industries Ltd. Schlebach Quadro 25.4, 38.1, 50.8 (1, 1-1/2, 2) ML 228.6 (9) 508 (20) None stated
Raven Roofing Ltd. Snap Lock 675 44.45 (1-3/4) SL 304.8 (12) 508 (20) Optional 46 (150)
Raven Roofing Ltd. SS 100 25.4 (1) ML 304.8 (12) 508 (20) 46 (150)
Raven Roofing Ltd. SS 150 38.1 (1-1/2) ML 304.8 (12) 508 (20) 46 (150)
Raven Roofing Ltd. Quadro FFQ 100 25.4 (1) SL 228.6 (9) 406.4 (16) 46 (150)
TRS Building Envelope (Tomtar Roofing) Knudson P-2401 50.8 (2) ML 304.8 (12) 508 (20) 46 (150)
TRS Building Envelope (Tomtar Roofing) Knudson KR-12 38.1 (1-1/2) ML 304.8 (12) 508 (20) 46 (150)
Top Line Roofing Ltd. Schlebach Quadro 25.4, 38.1, 50.8 (1, 1-1/2, 2) ML 228.6 (9) 508 (20) 46 (150)
Transwest Roofing Ltd. SS 100 25.4 (1) ML 304.8 (12) 508 (20) 46 (150)
Transwest Roofing Ltd. Snap Lock II 675 44.45 (1-3/4) SL 304.8 (12) 508 (20) Optional 46 (150)
Transwest Roofing Ltd. FF 100 25.4 (1) SL 304.8 (12) 508 (20) 46 (150)
Universal Sheet Metal Ltd. Knudson KR-12 38.1 (1-1/2) ML 304.8 (12) 508 (20) 46 (150)
Western Roofing (Master Roofers) Ltd. ESE 150 38.1 (1-1/2) ML 304.8 (12) 508 (20) 30.77 (100)

2 Pre-manufactured Metal Roof Systems

Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program
Manufacturer Product Name Profiles Seam Heights
mm (in.)
Seam Lock Type Panel Width (Range)
mm (in.)
Max. Panel Length
m (ft)
Elevate (fomerly Firestone) Una-Clad 38 (1 1/2) None stated
Garland Canada Inc. R-Mer Loc Snap 300, 400, 450 (12, 16, 18) None stated
Garland Canada Inc. R-Mer Loc LX None stated
Garland Canada Inc. R-Mer Span Snap Cap 300, 400, 450 (12, 16, 18) None stated
Garland Canada Inc. R-Mer Seam Snap Cap None stated
Precision Metals Ltd. NewTech FF 100 Metal Panel See TDS 23.4 (15/16) Snap 300 - 600 (12" - 24") None stated
Precision Metals Ltd. NewTech SS 100 Metal Panel See TDS 25.4 (1) Mechanical 300 - 600 (12" - 24") None stated
Westform Metals Nordic Clip 41 (1 5/8) 200 - 400 (8 - 16) None stated
Westform Metals Prolok 12 25 (1) Snap 300 - 400 (12 - 16) None stated