Difference between revisions of "Design Considerations"

Jump to: navigation, search

Difference between revisions of "Design Considerations"

 
(15 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
{{Template:RPM Info}}
 +
 +
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
 +
  <div class="col-md-3" style="float:right;" id="tocDiv">
 +
      __TOC__
 +
  </div> <!-- tocDiv -->
 +
 +
  <div class="col-md-9" id="mainBodyDiv">
 +
 +
<big><big>Division E - General Information</big></big>
 +
<hr>
 +
<big><big><big><big><big>Design Considerations</big></big></big></big></big>
 +
{| class="wikitable" | style="color: black; background-color: #ffffcc; width: 100%;"
 +
| colspan="2"  | '''NOTICE TO READER''': This is an <u>information page only</u>.  To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']].
 +
|}
 +
 
This section deals with roof system design considerations.  
 
This section deals with roof system design considerations.  
  
Although every situation cannot be dealt with specifically, an overview of roof system components and their function is provided. Each component is discussed in general terms and the properties / capabilities are outlined relative to similar components having the same function. The intention is not to assess or directly compare specific products. Space has been provided for "RGC Accepted Materials" manufacturers (see Section 2.2) to provide technical product information. (See also Section 4.5, Section 5, and Section 6 for specific membrane information.)
+
Although every situation cannot be dealt with specifically, an overview of roof system components and their function is provided. Each component is discussed in general terms and the properties / capabilities are outlined relative to similar components having the same function. The intention is not to assess or directly compare specific products. Space has been provided for [http://rpm.rcabc.org/index.php?title=Materials_by_Product_Type '''RoofStar Accepted Materials'''] manufacturers to provide technical product information. (See also [http://rpm.rcabc.org/index.php?title=Low_Slope_Membrane_Roofs '''Low Slope Roofs'''] and [http://rpm.rcabc.org/index.php?title=Steep_Slope_Roofs '''Steep Slope Roofs'''] for specific roof covering material information.)
  
 
The design authority is responsible for both the design of the roof system and the selection and specification of the various elements within the system, as they relate to the specific project. Many factors affect the life of a roof system and should be of concern to the owner and design authority.  
 
The design authority is responsible for both the design of the roof system and the selection and specification of the various elements within the system, as they relate to the specific project. Many factors affect the life of a roof system and should be of concern to the owner and design authority.  
Line 8: Line 24:
 
* poor application or carelessness on the part of the roofing contractor
 
* poor application or carelessness on the part of the roofing contractor
 
* selection of a roofing contractor unfamiliar with the products/system specified (usually based on price)
 
* selection of a roofing contractor unfamiliar with the products/system specified (usually based on price)
* poor work practices on the part of the general contractor or other subtrades
+
* poor work practices on the part of the general contractor or other sub-trades
 
* inadequate or lack of inspection of the installation and conformance to specifications
 
* inadequate or lack of inspection of the installation and conformance to specifications
 
* lack of representation and technical support from the membrane / material manufacturer  
 
* lack of representation and technical support from the membrane / material manufacturer  
 
* incorrect selection of materials
 
* incorrect selection of materials
 
* poor quality of materials
 
* poor quality of materials
 
+
</div><!-- mainBodyDiv -->
 
+
</div><!-- row -->
 +
<div class="col-md-12">
 
<hr>
 
<hr>
  
 +
[[Main Page | <i class="fa fa-home fa"></i> Home]]
 +
</div>
  
 
+
{{Tempate:RPM Page Footer with Copyright and Current Date}}
[[Section:B. Essential Elements|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Essential Elements'']]
 
 
 
[[Roof Classes|<i class="fa fa-chevron-circle-right fa-2x" ></i> ''Roof Classes'']]
 

Latest revision as of 15:33, 9 September 2021


Division E - General Information


Design Considerations

NOTICE TO READER: This is an information page only. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in Division B.

This section deals with roof system design considerations.

Although every situation cannot be dealt with specifically, an overview of roof system components and their function is provided. Each component is discussed in general terms and the properties / capabilities are outlined relative to similar components having the same function. The intention is not to assess or directly compare specific products. Space has been provided for RoofStar Accepted Materials manufacturers to provide technical product information. (See also Low Slope Roofs and Steep Slope Roofs for specific roof covering material information.)

The design authority is responsible for both the design of the roof system and the selection and specification of the various elements within the system, as they relate to the specific project. Many factors affect the life of a roof system and should be of concern to the owner and design authority.

Roof failures may occur as a result of:

  • poor application or carelessness on the part of the roofing contractor
  • selection of a roofing contractor unfamiliar with the products/system specified (usually based on price)
  • poor work practices on the part of the general contractor or other sub-trades
  • inadequate or lack of inspection of the installation and conformance to specifications
  • lack of representation and technical support from the membrane / material manufacturer
  • incorrect selection of materials
  • poor quality of materials