Difference between revisions of "ASM Ridge (Unvented, Uninsulated)"

Jump to: navigation, search

Difference between revisions of "ASM Ridge (Unvented, Uninsulated)"

(RIDGE / HIP CAP FLASHING)
(WORK INCLUDED)
 
(22 intermediate revisions by the same user not shown)
Line 1: Line 1:
[[File:8.1.4.11.1.jpg]]
+
{{Template:RPM Info}}
  
=== WORK INCLUDED ===
+
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
 +
__NOTOC__
  
(1) <b>Underlayment</b>: The type of underlay required is determined by roof slope (see Section 8.1.4.1 and Section 8.1.4.2).  
+
<big><big>Division D - Construction Details</big></big>
 +
<hr>
 +
<big><big><big><big><big>ASM | Ridge (Unvented, Uninsulated) ([[ASM_Roof_Systems_Standard#10.3.2.3. General Application Requirements for Perimeters and Walls | Article 10.3.2.3.]] and [[ASM_Roof_Systems_Standard#10.3.4.1. Ridges | Article 10.3.4.1.]])</big></big></big></big></big>
 +
{{Template:Construction Details Header}}
 +
<div class="panel panel-success">
 +
<div class="panel-heading"><big>'''SBS Details'''</big></div>
 +
<div class="panel-body">
 +
<div class="col-md-6">
 +
<div style="text-align:center; vertical-align:center">
 +
[[File:ASM 10.4.1 Ridge (Unvented).jpg|class=img-responsive | link=http://rpm.rcabc.org/images/5/59/ASM_10.4.1_Ridge_%28Unvented%29.jpg]]
 +
</div>
  
(2) <b>Slip Sheet</b>: Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
+
::Click below for a printable version of this page (N/A)
  
(3) <b>Architectural Metal Roof Panel</b>: Turn up (bread panned) at termination and drag load fastened with compatible non-corrosive fasteners.
+
<div style="width:150px; text-align: left;">
 +
:[[File:Pdf.png|100 px|link=http://rpm.rcabc.org/images/5/52/D1.7.6-3_Print_Sheet.pdf|'''Print Sheet''']]
 +
</div>
  
(4) <b>&#8216;Z&#8217; Closure</b>: Set in accepted caulking and secured with compatible non-corrosive, flathead fasteners.
 
  
:<b>OR</b>  
+
</div><!-- COL-MD-6 -->
  
(5) <b>Preformed Foam Closure</b>: Set in accepted caulking.  
+
<div class="col-md-6">
 +
=== WORK INCLUDED ===
 +
;(1) [[ASM Roof Systems Standard#8.1.3.3. Field Underlayment|'''Underlayment''']]: The type of underlay required is determined by roof slope.
 +
;(2) [[ASM Roof Systems Standard#8.1.3.5. Ventilation Beneath Panels|'''Ventilation layer''']]: A ventilation space is required on slopes less than 1:3; entangled mesh (shown) may be used as void fill.  The ventilation space facilitates drying as condensation forms on the underside of the metal panels.
 +
;(3) [[ASM Roof Systems Standard#9.2.1.5.Clips |'''Architectural metal panel clip''']]
 +
;(4) [[ASM Roof Systems Standard#9.3.2.6. Panel Terminations |''''Z' Closure''']]: Set in accepted sealant or butyl tape and secured with compatible non-corrosive flathead fasteners.
 +
;(5) [[ASM Roof Systems Standard#9.2.1.7. Sealants |'''Sealant''']]
 +
;(6) [[ASM Roof Systems Standard#9.1.3.2. System Securement |'''Drag-load fasteners''']]: Compatible non-corrosive fasteners.
 +
;(7) [[ASM Roof Systems Standard#9.3.2.6. Panel Terminations |'''Architectural metal roof panel''']]: Top end of panels must be "bread-panned".
 +
;(8) [[ASM Roof Systems Standard#10.3.4.1. Ridges | '''Ridge cap flashing''']]: Cut away to reveal 'Z' closure and drag-load fasteners.
  
(6) <b>Metal Cap Flashing</b>: Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under 12.7 mm (1/2"). Fastened to each standing seam with high domed gasketed cladding screws or hooked to &#8216;Z&#8217; closures.
+
<hr>
 
 
(7) <b>Drag Load Fastening</b>: Compatible non-corrosive fasteners.
 
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
 +
;(A) [[ASM Roof Systems Standard#PART_2|'''Acceptable Deck''']]
 +
</div><!-- COL-6-MD -->
 +
</div><!-- PANEL BODY -->
 +
</div><!-- PANEL -->
  
(A) <b>Acceptable Deck</b>
+
'''NOTE''': See the [[ASM Roof Systems Standard | '''Standard''']] for additional requirements.
 
 
(B) <b>Wood Nailer</b>
 
 
 
NOTE: * Refer to <i>RGC Guarantee Standards</i> for additional requirements.  
 
  
 
<hr>
 
<hr>
  
 +
[[ASM Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Roof System Details'']]
  
 +
[[Main Page | <i class="fa fa-home fa"></i> Home]]
  
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Construction Details'']]
+
{{Tempate:RPM Page Footer with Copyright and Current Date}}

Latest revision as of 17:54, 28 June 2022



Division D - Construction Details


ASM | Ridge (Unvented, Uninsulated) ( Article 10.3.2.3. and Article 10.3.4.1.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

SBS Details

ASM 10.4.1 Ridge (Unvented).jpg

Click below for a printable version of this page (N/A)
Print Sheet


1 WORK INCLUDED

(1) Underlayment
The type of underlay required is determined by roof slope.
(2) Ventilation layer
A ventilation space is required on slopes less than 1:3; entangled mesh (shown) may be used as void fill. The ventilation space facilitates drying as condensation forms on the underside of the metal panels.
(3) Architectural metal panel clip
(4) 'Z' Closure
Set in accepted sealant or butyl tape and secured with compatible non-corrosive flathead fasteners.
(5) Sealant
(6) Drag-load fasteners
Compatible non-corrosive fasteners.
(7) Architectural metal roof panel
Top end of panels must be "bread-panned".
(8) Ridge cap flashing
Cut away to reveal 'Z' closure and drag-load fasteners.

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

NOTE: See the Standard for additional requirements.


Back to ASM Roof System Details

Home

© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.