Difference between revisions of "Materials:(Bothwell-Accurate) BA-Versaspan 100 (SS 100)"
Difference between revisions of "Materials:(Bothwell-Accurate) BA-Versaspan 100 (SS 100)"
(→PERFORMANCE REQUIREMENTS) |
|||
(15 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
__NOTOC__ | __NOTOC__ | ||
__NONUMBEREDHEADINGS__ | __NONUMBEREDHEADINGS__ | ||
+ | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
+ | |||
+ | <big><big>Division C - Accepted Materials</big></big> | ||
+ | <hr> | ||
+ | <big><big><big><big><big>BA Versaspan 100 (SS 100)</big></big></big></big></big><br> | ||
+ | <big><big><big>by Bothwell-Accurate Company (B.C.) Ltd.</big></big></big><br> | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 10: | Line 16: | ||
;'''Manufacturer''': Bothwell-Accurate Company (B.C.) Ltd. | ;'''Manufacturer''': Bothwell-Accurate Company (B.C.) Ltd. | ||
;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] | ;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] | ||
− | ;'''Product Group - Standing Seam Metal Roof System''': New | + | ;'''Product Group - Standing Seam Metal Roof System''' |
+ | ;'''Panel Machine''': New Tech | ||
+ | ;'''Panel Name''': BA-Versaspan 1 (SS 100) | ||
+ | ;'''Seam Type''': Snap Lock | ||
The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. | The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. | ||
Line 17: | Line 26: | ||
====OVERVIEW==== | ====OVERVIEW==== | ||
− | The BA- | + | The BA-Versaspan 100 (SS 100) standing seam panel is formed with an on-site/in-shop continuous metal roofing panel roll forming machine (New Tech SS Multipro). This machine produces a standing seam panel with a seam height of 25.4 mm (1") and profiles can vary from 330.2 mm (13") wide up to 533.4 mm (21") wide. This machine also produces FF 100 (BA-Versasnap), SS 675 (BA-Versaclip), SS 150 (BA-Versaspan 150). |
+ | |||
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to 200' plus (depending on coil size and handling/maneuvering. | On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to 200' plus (depending on coil size and handling/maneuvering. | ||
====SYSTEM DESCRIPTION==== | ====SYSTEM DESCRIPTION==== | ||
− | #'''General''': The BA- | + | #'''General''': The BA-Versaspan 100 (SS 100) is a standing seam concealed fastener roof panel. The panel is attached with clips to allow for expansion and contraction. The maximum spacing of the clips and fasteners are 76.2mm (3'). |
#'''Range of application''': Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction. Considered a traditional standing seam panel. | #'''Range of application''': Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction. Considered a traditional standing seam panel. | ||
#'''Fasteners (Screws)''': Fasteners used to attach panel clips to plywood to be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used. | #'''Fasteners (Screws)''': Fasteners used to attach panel clips to plywood to be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used. | ||
#'''Roof Deck Fasteners (Panel Clips)''': One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 900 mm (36") O.C., fastened to plywood deck. | #'''Roof Deck Fasteners (Panel Clips)''': One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 900 mm (36") O.C., fastened to plywood deck. | ||
+ | #'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | ||
====PROFILE==== | ====PROFILE==== | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
− | ! BA-Versaspan | + | ! BA-Versaspan 100 (SS 100) Standing Seam Panel |
|- | |- | ||
− | | [[File:BA- | + | | [[File:BA-Versaspan 100 (SS 100) Panel.jpg|frameless|link=https://rpm.rcabc.org/images/9/96/BA-Versaspan_100_%28SS_100%29_Panel.jpg|750px]] |
|} | |} | ||
Line 38: | Line 49: | ||
<div style="width:150px; text-align: left;"> | <div style="width:150px; text-align: left;"> | ||
− | [[File:Pdf.png|75 px|link= | + | [[File:Pdf.png|75 px|link=https://rpm.rcabc.org/images/1/1c/BA_VERSASPAN_100_STANDING_SEAM_TDS.pdf|'''Technical Data Sheet''']] |
</div> | </div> | ||
Line 45: | Line 56: | ||
====PERFORMANCE REQUIREMENTS==== | ====PERFORMANCE REQUIREMENTS==== | ||
− | + | <ol> | |
− | + | <li>'''Wind Uplift Resistance''': Panel securement shall conform to the requirements in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#PART_3 Part 3] of the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | |
+ | <li>'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#Section_9.2._Materials Section 9.2.] of the Standard. | ||
+ | </li></ol> | ||
<hr> | <hr> |
Latest revision as of 17:07, 26 October 2023
Division C - Accepted Materials
BA Versaspan 100 (SS 100)
by Bothwell-Accurate Company (B.C.) Ltd.
The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program. |
The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. |
OVERVIEW
The BA-Versaspan 100 (SS 100) standing seam panel is formed with an on-site/in-shop continuous metal roofing panel roll forming machine (New Tech SS Multipro). This machine produces a standing seam panel with a seam height of 25.4 mm (1") and profiles can vary from 330.2 mm (13") wide up to 533.4 mm (21") wide. This machine also produces FF 100 (BA-Versasnap), SS 675 (BA-Versaclip), SS 150 (BA-Versaspan 150).
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to 200' plus (depending on coil size and handling/maneuvering.
SYSTEM DESCRIPTION
- General: The BA-Versaspan 100 (SS 100) is a standing seam concealed fastener roof panel. The panel is attached with clips to allow for expansion and contraction. The maximum spacing of the clips and fasteners are 76.2mm (3').
- Range of application: Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction. Considered a traditional standing seam panel.
- Fasteners (Screws): Fasteners used to attach panel clips to plywood to be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used.
- Roof Deck Fasteners (Panel Clips): One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 900 mm (36") O.C., fastened to plywood deck.
- Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.
PROFILE
BA-Versaspan 100 (SS 100) Standing Seam Panel |
---|
TECHNICAL DATA SHEET
Click below for the Technical Data Sheet
SITE CONDITIONS
Minimum roof slope is 1:12 (1" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:4 (3" in 12").
PERFORMANCE REQUIREMENTS
- Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
- Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.