Difference between revisions of "Materials:(Marine) MR/S-200"
Difference between revisions of "Materials:(Marine) MR/S-200"
(→OVERVIEW) |
(→PERFORMANCE REQUIREMENTS) |
||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
__NOTOC__ | __NOTOC__ | ||
__NONUMBEREDHEADINGS__ | __NONUMBEREDHEADINGS__ | ||
+ | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
+ | |||
+ | <big><big>Division C - Accepted Materials</big></big> | ||
+ | <hr> | ||
+ | <big><big><big><big><big>MR/S-200</big></big></big></big></big><br> | ||
+ | <big><big><big>by Marine Roofing (1996) Ltd.</big></big></big><br> | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 19: | Line 25: | ||
====OVERVIEW==== | ====OVERVIEW==== | ||
− | The New Tech Machinery Panel Machine is an on-site continuous panel metal roofing machine. This machine produces MR/S-200 panels with a seam height of 50 mm (2"). Panel profiles vary from 300 mm (12") to | + | The New Tech Machinery Panel Machine is an on-site continuous panel metal roofing machine. This machine produces MR/S-200 panels with a seam height of 50 mm (2"). Panel profiles vary from 300 mm (12") to 600 mm (24") wide. |
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal 46 m (150'). | On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal 46 m (150'). | ||
Line 27: | Line 33: | ||
#'''Range of application''': on wood or metal sloped roofs with or without exterior insulation; in commercial, institutional, industrial and residential construction; for re-roofing or new construction. | #'''Range of application''': on wood or metal sloped roofs with or without exterior insulation; in commercial, institutional, industrial and residential construction; for re-roofing or new construction. | ||
#'''Fasteners (Screws)''': Fasteners used to attach panel clips to steel to be No. 10-16 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated screw. Minimum two fasteners per clip to be used. | #'''Fasteners (Screws)''': Fasteners used to attach panel clips to steel to be No. 10-16 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated screw. Minimum two fasteners per clip to be used. | ||
− | #'''Panel Clips''': One piece assembly 43.75 mm (1-3/4") wide, | + | #'''Panel Clips''': One piece assembly 43.75 mm (1-3/4") wide, 52 mm (2-1/16") high. Minimum thickness 0.022". (No. 22 MSG). Clips spaced 600 mm (24") on centre fastened to plywood deck. Englert "series 1000 Interlocking Clip". |
#'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | #'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | ||
====PROFILE==== | ====PROFILE==== | ||
− | + | {| class="wikitable" | |
+ | |- | ||
+ | ! Marine MRS-200 Standing Seam (Mechanical Lock) Panel | ||
+ | |- | ||
+ | | [[File:Marine MRS-200 Panel.jpg|frameless|link=https://rpm.rcabc.org/images/b/bd/Marine_MRS-200_Panel.jpg|750px]] | ||
+ | |} | ||
====TECHNICAL DATA SHEET==== | ====TECHNICAL DATA SHEET==== | ||
Line 41: | Line 52: | ||
====PERFORMANCE REQUIREMENTS==== | ====PERFORMANCE REQUIREMENTS==== | ||
− | + | <ol> | |
− | + | <li>'''Wind Uplift Resistance''': Panel securement shall conform to the requirements in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#PART_3 Part 3] of the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | |
+ | <li>'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#Section_9.2._Materials Section 9.2.] of the Standard. | ||
+ | </li></ol> | ||
<hr> | <hr> |
Latest revision as of 17:23, 26 October 2023
Division C - Accepted Materials
MR/S-200
by Marine Roofing (1996) Ltd.
The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program. |
The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. |
OVERVIEW
The New Tech Machinery Panel Machine is an on-site continuous panel metal roofing machine. This machine produces MR/S-200 panels with a seam height of 50 mm (2"). Panel profiles vary from 300 mm (12") to 600 mm (24") wide.
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal 46 m (150').
SYSTEM DESCRIPTION
- General: Standing seam panels use a hidden fastening clip system for mechanical fastening to a solid substrate. The maximum spacing of the clips is 600 mm (24") on centre. The panels are locked together with the clips as part of the seam, by use of a mechanical seamer.
- Range of application: on wood or metal sloped roofs with or without exterior insulation; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
- Fasteners (Screws): Fasteners used to attach panel clips to steel to be No. 10-16 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated screw. Minimum two fasteners per clip to be used.
- Panel Clips: One piece assembly 43.75 mm (1-3/4") wide, 52 mm (2-1/16") high. Minimum thickness 0.022". (No. 22 MSG). Clips spaced 600 mm (24") on centre fastened to plywood deck. Englert "series 1000 Interlocking Clip".
- Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.
PROFILE
Marine MRS-200 Standing Seam (Mechanical Lock) Panel |
---|
TECHNICAL DATA SHEET
N/A
SITE CONDITIONS
- Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
PERFORMANCE REQUIREMENTS
- Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
- Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.