Difference between revisions of "Materials:(Lam) Schlebach 1""
Difference between revisions of "Materials:(Lam) Schlebach 1""
(→PERFORMANCE REQUIREMENTS) |
|||
(5 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | + | __NOTOC__ | |
+ | __NONUMBEREDHEADINGS__ | ||
+ | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
− | Contact Address: See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ | + | <big><big>Division C - Accepted Materials</big></big> |
+ | <hr> | ||
+ | <big><big><big><big><big>Schlebach 1"</big></big></big></big></big><br> | ||
+ | <big><big><big>by Lam Metal Contracting Ltd.</big></big></big><br> | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | style="background-color: #ffffcc; column-width:100%" | The metal panel listed and described below is accepted for use in the '''''RoofStar Guarantee Program'''''. | ||
+ | |} | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | | ||
+ | ;'''Manufacturer''': Lam Metal Contracting Ltd. | ||
+ | ;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] | ||
+ | ;'''Product Group - Standing Seam Metal Roof System''' | ||
+ | ;'''Panel Machine''': | ||
+ | ;'''Panel Name''': Schlebach 1" | ||
+ | ;'''Seam Type''': Mechanical Lock | ||
− | + | The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. | |
+ | |} | ||
− | + | ====OVERVIEW==== | |
+ | The Schlebach 1" Standing Seam metal roofing is a shop formed and an on-site continuous panel metal roofing machine. Panel profiles vary from 300 mm (12") to 500 mm (20") (standard width is 13", 15" or 20") with a seam height of 1". It can be rolled square, tapered and curved. It comes with no stiffening rib, with stiffening ribs and striation. | ||
− | : | + | ====SYSTEM DESCRIPTION==== |
+ | #'''General''': Standing seam panels employ a hidden fastening system for securement to a solid substrate. Panels are seamed together with a mechanical seamer. | ||
+ | #'''Range of application''': on wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction. | ||
+ | #'''Fasteners (Screws)''': To secure panel clips to steel, use No. 12-16 by 22 mm (1") long self-drilling, self-tapping, hex-washer head plated steel screws without sealing washers. Two fasteners per panel clip used, inserted into panel clip guide holes. | ||
+ | #'''Panel Clips''': Two-piece assembly consisting of a No. 18 or No. 16 MSG min. thick coated steel base approximately 22 mm (1") wide x 125 mm (5") long and No. 24 MSG min thick steel upper tap section height 22 mm (1") as manufactured by metal Roofing Supply Inc. in Denver. One panel clip spaced at 600 mm (24") O.C. | ||
+ | #'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | ||
− | + | ====PROFILE==== | |
− | + | N/A | |
− | + | ====TECHNICAL DATA SHEET==== | |
− | + | N/A | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | ====SITE CONDITIONS==== | |
− | + | #Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12"). | |
− | + | ====PERFORMANCE REQUIREMENTS==== | |
− | + | <ol> | |
− | + | <li>'''Wind Uplift Resistance''': Panel securement shall conform to the requirements in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#PART_3 Part 3] of the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | |
− | + | <li>'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#Section_9.2._Materials Section 9.2.] of the Standard. | |
+ | </li></ol> | ||
<hr> | <hr> |
Latest revision as of 17:15, 26 October 2023
Division C - Accepted Materials
Schlebach 1"
by Lam Metal Contracting Ltd.
The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program. |
The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. |
OVERVIEW
The Schlebach 1" Standing Seam metal roofing is a shop formed and an on-site continuous panel metal roofing machine. Panel profiles vary from 300 mm (12") to 500 mm (20") (standard width is 13", 15" or 20") with a seam height of 1". It can be rolled square, tapered and curved. It comes with no stiffening rib, with stiffening ribs and striation.
SYSTEM DESCRIPTION
- General: Standing seam panels employ a hidden fastening system for securement to a solid substrate. Panels are seamed together with a mechanical seamer.
- Range of application: on wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
- Fasteners (Screws): To secure panel clips to steel, use No. 12-16 by 22 mm (1") long self-drilling, self-tapping, hex-washer head plated steel screws without sealing washers. Two fasteners per panel clip used, inserted into panel clip guide holes.
- Panel Clips: Two-piece assembly consisting of a No. 18 or No. 16 MSG min. thick coated steel base approximately 22 mm (1") wide x 125 mm (5") long and No. 24 MSG min thick steel upper tap section height 22 mm (1") as manufactured by metal Roofing Supply Inc. in Denver. One panel clip spaced at 600 mm (24") O.C.
- Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.
PROFILE
N/A
TECHNICAL DATA SHEET
N/A
SITE CONDITIONS
- Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
PERFORMANCE REQUIREMENTS
- Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
- Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.