Difference between revisions of "Materials:(Transwest) SS 100"
Difference between revisions of "Materials:(Transwest) SS 100"
(→PERFORMANCE REQUIREMENTS) |
|||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | + | __NOTOC__ | |
+ | __NONUMBEREDHEADINGS__ | ||
+ | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
− | Contact Address: See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ | + | <big><big>Division C - Accepted Materials</big></big> |
+ | <hr> | ||
+ | <big><big><big><big><big>SS 100</big></big></big></big></big><br> | ||
+ | <big><big><big>by Transwest Roofing Ltd.</big></big></big><br> | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | style="background-color: #ffffcc; column-width:100%" | The metal panel listed and described below is accepted for use in the '''''RoofStar Guarantee Program'''''. | ||
+ | |} | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | | ||
+ | ;'''Manufacturer''': Transwest Roofing Ltd. | ||
+ | ;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] | ||
+ | ;'''Product Group - Standing Seam Metal Roof System''' | ||
+ | ;'''Panel Machine''': New Tech Machinery | ||
+ | ;'''Panel Name''': (Transwest) SS 100 | ||
+ | ;'''Seam Type''': Mechanical Lock: 25 mm (1") | ||
− | + | The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. | |
+ | |} | ||
− | + | ====OVERVIEW==== | |
The New Tech Machinery Panel Machine is an on-site continuous metal roofing panel roll forming machine. This machine produces Seam Lock - SS 100 with a seam height of 22 mm (1"). Panel profiles vary from 300 mm (12") to 500 mm (20") wide. | The New Tech Machinery Panel Machine is an on-site continuous metal roofing panel roll forming machine. This machine produces Seam Lock - SS 100 with a seam height of 22 mm (1"). Panel profiles vary from 300 mm (12") to 500 mm (20") wide. | ||
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal 46m (150'). | On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal 46m (150'). | ||
− | ;1.1 | + | ====SYSTEM DESCRIPTION==== |
− | + | #'''General''': Standing seam panels use a hidden fastening clip system for mechanical fastening to a solid substrate. The maximum spacing of the clips is 600 mm (24") on centre. The panels are locked together, with the clips as part of the seam, by use of a mechanical seamer. | |
+ | #'''Range of application''': on wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction. | ||
+ | #'''Fasteners (Screws)''': | ||
+ | ##Fasteners used to attach panel clips to plywood to be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used. | ||
+ | #'''Clips''': | ||
+ | ##One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022 in.(No. 22 MSG). Clips spaced 600 mm (24") on centre fastened to plywood deck. Englert "Series 1000 Interlocking Clip". | ||
+ | #'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | ||
− | + | ====PROFILE==== | |
− | + | N/A | |
− | + | ====TECHNICAL DATA SHEET==== | |
+ | N/A | ||
− | :. | + | ====SITE CONDITIONS==== |
+ | #Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12"). | ||
− | + | ====PERFORMANCE REQUIREMENTS==== | |
− | + | <ol> | |
− | + | <li>'''Wind Uplift Resistance''': Panel securement shall conform to the requirements in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#PART_3 Part 3] of the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | |
− | + | <li>'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#Section_9.2._Materials Section 9.2.] of the Standard. | |
− | + | </li></ol> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
<hr> | <hr> |
Latest revision as of 17:28, 26 October 2023
Division C - Accepted Materials
SS 100
by Transwest Roofing Ltd.
The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program. |
The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. |
OVERVIEW
The New Tech Machinery Panel Machine is an on-site continuous metal roofing panel roll forming machine. This machine produces Seam Lock - SS 100 with a seam height of 22 mm (1"). Panel profiles vary from 300 mm (12") to 500 mm (20") wide.
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal 46m (150').
SYSTEM DESCRIPTION
- General: Standing seam panels use a hidden fastening clip system for mechanical fastening to a solid substrate. The maximum spacing of the clips is 600 mm (24") on centre. The panels are locked together, with the clips as part of the seam, by use of a mechanical seamer.
- Range of application: on wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
- Fasteners (Screws):
- Fasteners used to attach panel clips to plywood to be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used.
- Clips:
- One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022 in.(No. 22 MSG). Clips spaced 600 mm (24") on centre fastened to plywood deck. Englert "Series 1000 Interlocking Clip".
- Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.
PROFILE
N/A
TECHNICAL DATA SHEET
N/A
SITE CONDITIONS
- Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
PERFORMANCE REQUIREMENTS
- Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
- Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.