Difference between revisions of "Materials:(Cascade) Nu-Tech Snap-Loc"

Jump to: navigation, search

Difference between revisions of "Materials:(Cascade) Nu-Tech Snap-Loc"

(SYSTEM DESCRIPTION)
(PERFORMANCE REQUIREMENTS)
 
(4 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
__NOTOC__
 
__NOTOC__
 
__NONUMBEREDHEADINGS__
 
__NONUMBEREDHEADINGS__
 +
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
 +
 +
<big><big>Division C - Accepted Materials</big></big>
 +
<hr>
 +
<big><big><big><big><big>Nu-Tech Snap-Loc</big></big></big></big></big><br>
 +
<big><big><big>by Cascade Roofing & Exteriors Inc.</big></big></big><br>
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 11: Line 17:
 
;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org]
 
;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org]
 
;'''Product Group - Standing Seam Metal Roof System'''
 
;'''Product Group - Standing Seam Metal Roof System'''
;'''Panel Machine''': New Tech  
+
;'''Panel Machine''': New Tech Machinery
 
;'''Panel Name''': Snap-Loc
 
;'''Panel Name''': Snap-Loc
 
;'''Seam Type''': Snap Lock
 
;'''Seam Type''': Snap Lock
Line 28: Line 34:
 
#'''Fasteners (Screws)''': Fasteners used to attach panel clips to steel to be No. 10 - 16 by 25 mm (1") long cadmium plated pancake head, No. 2 Phillips drive, No. 3 self-drilling point steel screws. Two screws per clip inserted through 6.25 mm (&#188;") diameter guide holes.
 
#'''Fasteners (Screws)''': Fasteners used to attach panel clips to steel to be No. 10 - 16 by 25 mm (1") long cadmium plated pancake head, No. 2 Phillips drive, No. 3 self-drilling point steel screws. Two screws per clip inserted through 6.25 mm (&#188;") diameter guide holes.
 
#'''Panel Clips''': One-piece assembly, No. 22 MSG min. thick, 88 mm (3&#189;") high. One panel clip spaced at 600 mm (24") O.C. for Class 90.
 
#'''Panel Clips''': One-piece assembly, No. 22 MSG min. thick, 88 mm (3&#189;") high. One panel clip spaced at 600 mm (24") O.C. for Class 90.
 +
  
 
====PROFILE====
 
====PROFILE====
Line 39: Line 46:
  
 
====PERFORMANCE REQUIREMENTS====
 
====PERFORMANCE REQUIREMENTS====
#'''Wind Uplift Standards''': Engineered designs to resist wind uplift may refer to the British Columbia Building Code, Div. B, Appendix C, Table C-2 which lists various types of loads, including wind loads, for specific reference locations throughout the province. See also [http://{{SERVERNAME}}/index.php?title=ASM_Application_Guides_and_Notes Guides and Notes (Wind Resistance)] for a simplified calculation procedure. Regardless of the resources indicated here, the Design Authority is responsible to perform accurate wind load calculations and specify securement requirements.
+
<ol>
#'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the standards published in the [http://rpm.rcabc.org/index.php/RoofStar_Guarantee_Standards_for_ASM_Roof_Assemblies RoofStar Guarantee Standards for ASM Roof Assemblies].
+
<li>'''Wind Uplift Resistance''': Panel securement shall conform to the requirements in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#PART_3 Part 3] of the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].
 +
<li>'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#Section_9.2._Materials Section 9.2.] of the Standard.
 +
</li></ol>
  
 
<hr>
 
<hr>

Latest revision as of 17:08, 26 October 2023



Division C - Accepted Materials


Nu-Tech Snap-Loc
by Cascade Roofing & Exteriors Inc.

The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program.
Manufacturer
Cascade Roofing & Exteriors Inc.
Contact Address
See the current Membership list and contact information at www.rcabc.org
Product Group - Standing Seam Metal Roof System
Panel Machine
New Tech Machinery
Panel Name
Snap-Loc
Seam Type
Snap Lock

The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer.

OVERVIEW

The Nu-Tech Snap-Loc is an on-site continuous panel metal roofing machine. Panel profiles vary from 300 mm (12") to 457 mm (18") wide with a 44 mm (1¾") rib.

On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal 46 m (150').

SYSTEM DESCRIPTION

  1. General: The Snap-Loc Nu-Tech 44 mm (1¾") is a snap lock concealed fastener roofing panel. The panel can be formed in any width between 300 mm (12") to 457 mm (18"). Stiffening ribs, striations and / or clip relief can be added depending on the application. The male leg locks along the entire length of the panel and does not rely upon clips to provide additional locking. The Snap-Loc Nu-Tech utilizes 153 mm (61/8") of metal in forming the panel legs providing greater structural integrity, which can carry greater loads.
  2. Range of application: On wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
  3. Fasteners (Screws): Fasteners used to attach panel clips to steel to be No. 10 - 16 by 25 mm (1") long cadmium plated pancake head, No. 2 Phillips drive, No. 3 self-drilling point steel screws. Two screws per clip inserted through 6.25 mm (¼") diameter guide holes.
  4. Panel Clips: One-piece assembly, No. 22 MSG min. thick, 88 mm (3½") high. One panel clip spaced at 600 mm (24") O.C. for Class 90.


PROFILE

N/A

TECHNICAL DATA SHEET

N/A

SITE CONDITIONS

Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").

PERFORMANCE REQUIREMENTS

  1. Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
  2. Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.