Difference between revisions of "Materials:(G&G) Knudson KR-21 VP Varipan"
Difference between revisions of "Materials:(G&G) Knudson KR-21 VP Varipan"
(Created page with "__NOTOC__ __NONUMBEREDHEADINGS__ {| class="wikitable" |- | style="background-color: #ffffcc; column-width:100%" | The metal panel listed and described below is accepted for us...") |
|||
(9 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
__NOTOC__ | __NOTOC__ | ||
__NONUMBEREDHEADINGS__ | __NONUMBEREDHEADINGS__ | ||
+ | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
+ | |||
+ | <big><big>Division C - Accepted Materials</big></big> | ||
+ | <hr> | ||
+ | <big><big><big><big><big>Knudson KR-21 VP Varipan</big></big></big></big></big><br> | ||
+ | <big><big><big>by G&G Roofing Ltd.</big></big></big><br> | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 11: | Line 17: | ||
;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] | ;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] | ||
;'''Product Group - Standing Seam Metal Roof System''' | ;'''Product Group - Standing Seam Metal Roof System''' | ||
− | ;'''Panel Machine''': Knudson | + | ;'''Panel Machine''': Knudson Model KR-21VP VARIPAN |
;'''Panel Name''': Knudson KR-21 VP Varipan | ;'''Panel Name''': Knudson KR-21 VP Varipan | ||
;'''Seam Type''': Mechanical | ;'''Seam Type''': Mechanical | ||
Line 27: | Line 33: | ||
#'''Range of application''': Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction. | #'''Range of application''': Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction. | ||
#'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications. | #'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications. | ||
− | #'''Fasteners (Screws)''': Fasteners used to attach panel clips to | + | #'''Fasteners (Screws)''': |
− | #'''Panel Clips''': One piece assembly | + | ##Fasteners used to attach panel clips to steel must be No. 10-16 by 25 mm (1") long self-drilling, self-tapping pancake head plates steel screws. Use two fasteners per panel clip, inserted into panel clip guide holes. |
+ | ##Fasteners used to attach panel clips to plywood must be No. 10-16 by 25 mm (1") long pancake head plated steel screws for wood. Use two fasteners per clip, inserted into panel guide holes. | ||
+ | #'''Panel Clips''': One piece assembly 38 mm (1-1/2") wide, 47 mm (1-5/8") high, manufactured by Knudson (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C. | ||
+ | #'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | ||
====PROFILE==== | ====PROFILE==== | ||
Line 37: | Line 46: | ||
====SITE CONDITIONS==== | ====SITE CONDITIONS==== | ||
− | Minimum roof slope is 1: | + | Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12"). |
====PERFORMANCE REQUIREMENTS==== | ====PERFORMANCE REQUIREMENTS==== | ||
− | + | <ol> | |
− | + | <li>'''Wind Uplift Resistance''': Panel securement shall conform to the requirements in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#PART_3 Part 3] of the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | |
+ | <li>'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#Section_9.2._Materials Section 9.2.] of the Standard. | ||
+ | </li></ol> | ||
<hr> | <hr> |
Latest revision as of 17:04, 27 October 2023
Division C - Accepted Materials
Knudson KR-21 VP Varipan
by G&G Roofing Ltd.
The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program. |
The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. |
OVERVIEW
The Knudson KR-21 VP Varipan standing seam panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine ( New Tech SS Multipro ). This machine produces a standing seam panel with a seam height of 38 mm (1 1/2") and profiles can vary from 305mm (12") wide up to 500 mm (20") wide.
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to 300'.
SYSTEM DESCRIPTION
- General: The Knudson KR-21 VP Varipan is standing seam concealed fastener roof panel. The maximum spacing of screws in the built in nailing strip is 635mm (24")
- Range of application: Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction.
- Panel Attachment: Fastening is site specific, engineer must confirm fixing specifications.
- Fasteners (Screws):
- Fasteners used to attach panel clips to steel must be No. 10-16 by 25 mm (1") long self-drilling, self-tapping pancake head plates steel screws. Use two fasteners per panel clip, inserted into panel clip guide holes.
- Fasteners used to attach panel clips to plywood must be No. 10-16 by 25 mm (1") long pancake head plated steel screws for wood. Use two fasteners per clip, inserted into panel guide holes.
- Panel Clips: One piece assembly 38 mm (1-1/2") wide, 47 mm (1-5/8") high, manufactured by Knudson (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C.
- Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.
PROFILE
N/A
TECHNICAL DATA SHEET
N/A
SITE CONDITIONS
Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
PERFORMANCE REQUIREMENTS
- Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
- Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.