Difference between revisions of "Materials:(Marine) MR/S-100"

Jump to: navigation, search

Difference between revisions of "Materials:(Marine) MR/S-100"

(Created page with "Manufacturer: <b>MARINE ROOFING (1996) LTD.</b> Contact Address: See Membership List in Section 1. Product Group: <b>STANDING SEAM METAL ROOF SYSTEM – MR/S-100</b>...")
 
(PERFORMANCE REQUIREMENTS)
 
(9 intermediate revisions by the same user not shown)
Line 1: Line 1:
Manufacturer: <b>MARINE ROOFING (1996) LTD.</b>  
+
__NOTOC__
 +
__NONUMBEREDHEADINGS__
 +
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
  
Contact Address: See Membership List in Section 1.  
+
<big><big>Division C - Accepted Materials</big></big>
 
+
<hr>
Product Group: <b>STANDING SEAM METAL ROOF SYSTEM &#8211; MR/S-100</b>
+
<big><big><big><big><big>MR/S-100</big></big></big></big></big><br>
 +
<big><big><big>by Marine Roofing (1996) Ltd.</big></big></big><br>
 +
{| class="wikitable"
 +
|-
 +
| style="background-color: #ffffcc; column-width:100%" | The metal panel listed and described below is accepted for use in the '''''RoofStar Guarantee Program'''''.
 +
|}
 +
{| class="wikitable"
 +
|-
 +
|
 +
;'''Manufacturer''': Marine Roofing (1996) Ltd.
 +
;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org]
 +
;'''Product Group - Standing Seam Metal Roof System'''
 +
;'''Panel Machine''': New Tech Machinery
 +
;'''Panel Name''': MR/S-100
 +
;'''Seam Type''': Mechanical Lock
  
;DESCRIPTION
+
The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.  For more information about this product or system, consult the manufacturer.
 +
|}
  
 +
====OVERVIEW====
 
The New Tech Machinery Panel Machine is an on-site continuous panel metal roofing machine. This machine produces MR/S-100 panels with a seam height of 22 mm (1"). Panel profiles vary from 300 mm (12") to 500mm (20") wide.  
 
The New Tech Machinery Panel Machine is an on-site continuous panel metal roofing machine. This machine produces MR/S-100 panels with a seam height of 22 mm (1"). Panel profiles vary from 300 mm (12") to 500mm (20") wide.  
  
 
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal 46 m (150').
 
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal 46 m (150').
  
;1.1 <u>GENERAL</u>
+
====SYSTEM DESCRIPTION====
:The roofing assembly / material information published in the <b>RCABC <i>Roofing Practices Manual</i></b> DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
+
#'''General''': Standing seam panels use a hidden fastening clip system for mechanical fastening to a solid substrate. The maximum spacing of the clips is 600 mm (24") on centre. The panels are locked together with the clips as part of the seam, by use of a mechanical seamer.
 +
#'''Range of application''': on wood or metal sloped roofs with or without exterior insulation; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
 +
#'''Fasteners (Screws)''': Fasteners used to attach panel clips to steel to be No. 10-16 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated screw. Minimum two fasteners per clip to be used.  Two screws per clip inserted through 6.25 mm (1/4") diameter guide holes.
 +
#'''Panel Clips''': One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022". (No. 22 MSG). Clips spaced 600 mm (24") on centre fastened to plywood deck. Englert "series 1000 Interlocking Clip".
 +
#'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].].
  
;1.2 <u>SYSTEM DESCRIPTION</u>
+
====PROFILE====
:.1 Standing seam panels use a hidden fastening clip system for mechanical fastening to a solid substrate. The maximum spacing of the clips is 600 mm (24") on centre. The panels are locked together with the clips as part of the seam, by use of a mechanical seamer.
+
N/A
:.2 Range of application: on wood or metal sloped roofs with or without exterior insulation; in commercial, institutional, industrial and residential construction; for reroofing or new construction.
 
:;.3 <b>Panel Attachment:</b>
 
:;<u>Fasteners (Screws)</u>
 
::Fasteners used to attach panel clips to steel to be No. 10-16 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated screw. Minimum two fasteners per clip to be used.
 
:;<u>Roof Deck Fasteners (Panel Clips)</u>
 
::One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022". (No. 22 MSG). Clips spaced 600 mm (24") on centre fastened to plywood deck. Englert "series 1000 Interlocking Clip".
 
  
;1.3 <u>SITE CONDITIONS</u>
+
====TECHNICAL DATA SHEET====
:.1 Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
+
N/A
  
;1.4 <u>PERFORMANCE REQUIREMENTS</u>
+
====SITE CONDITIONS====
:;.1 <u>Wind Uplift Standards</u>:  
+
#Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").  
::National Research Council (NRC-CNRC) Report No.B1040 Wind Uplift Resistance of Metal Roofing. The NRC-CNRC Report No. B1040 test results confirm that an acceptable level of wind uplift resistance can be achieved with RGC Accepted Metal Panel Systems on typical roof designs over solid decking for most British Columbia geographical locations. Refer to Appendix II for calculations for typical roof wind uplift pressure requirements for buildings located in the Province of British Columbia.
 
 
:A simplified design procedure developed by NRC-CNRC for selecting wind pressure calculations for metal roof assemblies by region (location) and building height in the Province of British Columbia is provided in TAB 8.1.5 to assist designers.  
 
  
:RGC accepted metal panel systems shall be formed of steel conforming to one of the following material specifications, as applicable:
 
  
* ASTM Standard Specification A653 / A653M, Sheet Steel, Zinc-Coated (Galvanized) or Zinc-Iron Alloy Coated (Galvannealed) by the hot dip process, minimum Grade 33, with a design thickness of 24 gauge. (0.024") or greater and a minimum zinc coating designation Z275 (G-90).  
+
====PERFORMANCE REQUIREMENTS====
* ASTM Standard Specification A792 / A792M, Steel Sheet, 55% Aluminum-Zinc Alloy-Coated by the Hot-Dip Process, minimum Grade 33, with a design thickness of 24 gauge (0.024") or greater and minimum coating designation AZ150.
+
<ol>
 +
<li>'''Wind Uplift Resistance''': Panel securement shall conform to the requirements in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#PART_3 Part 3] of the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].
 +
<li>'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#Section_9.2._Materials Section 9.2.] of the Standard.
 +
</li></ol>
  
 
<hr>
 
<hr>
  
  
 +
[[Architectural Metal Roofing|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Site-Formed Metal Roofing Systems'']]
  
[[Architectural Metal Roofing|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Site-Formed Metal Roofing Systems'']]
+
[[Materials by Product Type|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Accepted Materials'']]
  
  
 
[[Main Page|Home]]
 
[[Main Page|Home]]

Latest revision as of 17:22, 26 October 2023



Division C - Accepted Materials


MR/S-100
by Marine Roofing (1996) Ltd.

The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program.
Manufacturer
Marine Roofing (1996) Ltd.
Contact Address
See the current Membership list and contact information at www.rcabc.org
Product Group - Standing Seam Metal Roof System
Panel Machine
New Tech Machinery
Panel Name
MR/S-100
Seam Type
Mechanical Lock

The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer.

OVERVIEW

The New Tech Machinery Panel Machine is an on-site continuous panel metal roofing machine. This machine produces MR/S-100 panels with a seam height of 22 mm (1"). Panel profiles vary from 300 mm (12") to 500mm (20") wide.

On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal 46 m (150').

SYSTEM DESCRIPTION

  1. General: Standing seam panels use a hidden fastening clip system for mechanical fastening to a solid substrate. The maximum spacing of the clips is 600 mm (24") on centre. The panels are locked together with the clips as part of the seam, by use of a mechanical seamer.
  2. Range of application: on wood or metal sloped roofs with or without exterior insulation; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
  3. Fasteners (Screws): Fasteners used to attach panel clips to steel to be No. 10-16 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated screw. Minimum two fasteners per clip to be used. Two screws per clip inserted through 6.25 mm (1/4") diameter guide holes.
  4. Panel Clips: One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022". (No. 22 MSG). Clips spaced 600 mm (24") on centre fastened to plywood deck. Englert "series 1000 Interlocking Clip".
  5. Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.].

PROFILE

N/A

TECHNICAL DATA SHEET

N/A

SITE CONDITIONS

  1. Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").


PERFORMANCE REQUIREMENTS

  1. Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
  2. Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.


Back to Site-Formed Metal Roofing Systems

Back to Accepted Materials


Home