Difference between revisions of "Materials:(Bothwell-Accurate) BA-Versasnap (FF 100)"
Difference between revisions of "Materials:(Bothwell-Accurate) BA-Versasnap (FF 100)"
(Created page with "__NOTOC__ __NONUMBEREDHEADINGS__ {| class="wikitable" |- | style="background-color: #ffffcc; column-width:100%" | The metal panel listed and described below is accepted for us...") |
|||
Line 10: | Line 10: | ||
;'''Manufacturer''': Bothwell-Accurate Company (B.C.) Ltd. | ;'''Manufacturer''': Bothwell-Accurate Company (B.C.) Ltd. | ||
;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] | ;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] | ||
− | ;'''Product Group - Standing Seam Metal Roof System''': BA- | + | ;'''Product Group - Standing Seam Metal Roof System''': BA-Versasnap (FF 100) |
The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. | The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. | ||
Line 16: | Line 16: | ||
====OVERVIEW==== | ====OVERVIEW==== | ||
+ | The FF100 (BA-Versasnap) standing seam panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine ( New Tech SS Multipro ). This machine produces a standing seam panel with a seam height of 23.4mm (7/8") and profiles can vary from 305mm (12") wide up to 635mm (24") wide. This machine also produces SS675 (BA-Versaclip), SS100 (BA-Versaspan1), SS150 (BA-Versaspan1.5). | ||
+ | |||
+ | On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to 200' plus (depending on coil size and handling/maneuvering. | ||
====SYSTEM DESCRIPTION==== | ====SYSTEM DESCRIPTION==== | ||
+ | #'''General''': The BA-Versasnap (FF100) is standing seam concealed fastener roof panel. The maximum spacing of screws in the built in nailing strip is 635mm (24") | ||
+ | #'''Range of application''': Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction. | ||
+ | #'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications. | ||
+ | ::* '''Fasteners (Screws)''': Fasteners used to attach panel clips to plywood to be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used. | ||
+ | ::* '''Roof Deck Fasteners (Panel Clips)''': One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 900 mm (36") O.C., fastened to plywood deck. | ||
====PROFILE==== | ====PROFILE==== | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! BA-Versaspan 1 (SS 100) Standing Seam Panel | ||
+ | |- | ||
+ | | [[File:BA-Versasnap (FF 100) Panel.jpg|frameless|link=Architectural Metal Roofing|750px]] | ||
+ | |} | ||
====TECHNICAL DATA SHEET==== | ====TECHNICAL DATA SHEET==== | ||
+ | Click below for the '''Technical Data Sheet''' | ||
+ | |||
+ | <div style="width:150px; text-align: left;"> | ||
+ | [[File:Pdf.png|75 px|link=http://rpm.rcabc.org/images/8/81/BA_-_Versasnap_%28FF_100%29_TDS.pdf|'''Technical Data Sheet''']] | ||
+ | </div> | ||
====SITE CONDITIONS==== | ====SITE CONDITIONS==== | ||
+ | Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12"). | ||
====PERFORMANCE REQUIREMENTS==== | ====PERFORMANCE REQUIREMENTS==== |
Revision as of 20:30, 24 August 2018
The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program. |
The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. |
OVERVIEW
The FF100 (BA-Versasnap) standing seam panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine ( New Tech SS Multipro ). This machine produces a standing seam panel with a seam height of 23.4mm (7/8") and profiles can vary from 305mm (12") wide up to 635mm (24") wide. This machine also produces SS675 (BA-Versaclip), SS100 (BA-Versaspan1), SS150 (BA-Versaspan1.5).
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to 200' plus (depending on coil size and handling/maneuvering.
SYSTEM DESCRIPTION
- General: The BA-Versasnap (FF100) is standing seam concealed fastener roof panel. The maximum spacing of screws in the built in nailing strip is 635mm (24")
- Range of application: Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction.
- Panel Attachment: Fastening is site specific, engineer must confirm fixing specifications.
- Fasteners (Screws): Fasteners used to attach panel clips to plywood to be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used.
- Roof Deck Fasteners (Panel Clips): One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 900 mm (36") O.C., fastened to plywood deck.
PROFILE
BA-Versaspan 1 (SS 100) Standing Seam Panel |
---|
750px |
TECHNICAL DATA SHEET
Click below for the Technical Data Sheet
SITE CONDITIONS
Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
PERFORMANCE REQUIREMENTS
- Wind Uplift Standards: Engineered designs to resist wind uplift may refer to the British Columbia Building Code, Div. B, Appendix C, Table C-2 which lists various types of loads, including wind loads, for specific reference locations throughout the province. See also Guides and Notes (Wind Resistance) for a simplified calculation procedure. Regardless of the resources indicated here, the Design Authority is responsible to perform accurate wind load calculations and specify securement requirements.