Difference between revisions of "Template:AARS Membrane - SBS 2-Ply Base"

Jump to: navigation, search

Difference between revisions of "Template:AARS Membrane - SBS 2-Ply Base"

Line 4: Line 4:
 
|+ How to use the table:
 
|+ How to use the table:
  
#Expand the table for the membrane type and look for maximum <u>wind uplift values that exceed</u> the requirements determined through the RCI calculator;<p>('''NOTE''': while the reports show two different values for tested maximum assembly strength, the RPM tables display only the values adjusted for the required safety factor of 1.5)</p>
+
#In the table below look for maximum <u>wind uplift values that exceed</u> the requirements determined through the RCI calculator;<p>('''NOTE''': while the reports show two different values for tested maximum assembly strength, the RPM tables display only the values adjusted for the required safety factor of 1.5)</p>
 
#Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report.  It will break down the assembly by its components.  Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the '''''RoofStar Guarantee Program''''' (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer);
 
#Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report.  It will break down the assembly by its components.  Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the '''''RoofStar Guarantee Program''''' (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer);
 
#In cases where a tested Secondary material is not accepted by the '''''RoofStar Guarantee Program''''', look for alternates which often are published in the each report.  In the absence of published alternates, locate a possible alternate in the [http://rpm.rcabc.org/index.php?title=Materials_by_Product_Type '''Accepted Materials'''] section of this Manual.  If you are unsure about compatibility, contact the [mailto:guarantees@rcabc.org '''RCABC'''].
 
#In cases where a tested Secondary material is not accepted by the '''''RoofStar Guarantee Program''''', look for alternates which often are published in the each report.  In the absence of published alternates, locate a possible alternate in the [http://rpm.rcabc.org/index.php?title=Materials_by_Product_Type '''Accepted Materials'''] section of this Manual.  If you are unsure about compatibility, contact the [mailto:guarantees@rcabc.org '''RCABC'''].

Revision as of 19:03, 18 July 2017

How to use the table:
  1. In the table below look for maximum wind uplift values that exceed the requirements determined through the RCI calculator;

    (NOTE: while the reports show two different values for tested maximum assembly strength, the RPM tables display only the values adjusted for the required safety factor of 1.5)

  2. Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report. It will break down the assembly by its components. Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the RoofStar Guarantee Program (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer);
  3. In cases where a tested Secondary material is not accepted by the RoofStar Guarantee Program, look for alternates which often are published in the each report. In the absence of published alternates, locate a possible alternate in the Accepted Materials section of this Manual. If you are unsure about compatibility, contact the RCABC.
Manufacturer Product Name Number of Tested Systems
(per report)
kPa (Low) kPa (High) Psf (Low) Psf (High) Deck Type Downloadable Test Report Test Facility Test Facility Report No.
Henry Company Canada Modified Plus G100 p / s 1 Tested System ---- -3.80 ---- -80.00 Steel AARS Test Report 2 Exova 14-06-M0115-3, Revision 1 (S)
Henry Company Canada Modified Plus NP180 Tack 1 Tested System ---- -4.79 ---- -100.00 Steel AARS Test Report 1 Exova 14-06-M0115-1B, Revision 1 (S)
IKO Industries Ltd. Modiflex HD-FS-Base 1 Tested System
1 Tested System
1 Tested System
----
----
----
-4.80
-2.40
-4.20
----
----
----
-100.00
-50.00
-87.00
Steel
Steel
Steel
AARS Test Report 1
AARS Test Report 2
AARS Test Report 3
exp. Service Inc. PUB-DRU292547
PUB-DRU285762
PUB-DRU285764
IKO Industries Ltd. Modiflex HD-SS-Base 1 Tested System
1 Tested System
1 Tested System
----
----
----
-4.80
-2.40
-4.20
----
----
----
-100.00
-50.00
-87.00
Steel
Steel
Steel
AARS Test Report 1
AARS Test Report 2
AARS Test Report 3
exp. Service Inc. PUB-DRU292547
PUB-DRU285762
PUB-DRU285764
IKO Industries Ltd. Modiflex MF-95 F/S 1 Tested System
1 Tested System
1 Tested System
----
----
----
-4.80
-2.40
-4.20
----
----
----
-100.00
-50.00
-87.00
Steel
Steel
Steel
AARS Test Report 1
AARS Test Report 2
AARS Test Report 3
exp. Service Inc. PUB-DRU292547
PUB-DRU285762
PUB-DRU285764
IKO Industries Ltd. Modiflex MF-95 S/S 1 Tested System
1 Tested System
1 Tested System
----
----
----
-4.80
-2.40
-4.20
----
----
----
-100.00
-50.00
-87.00
Steel
Steel
Steel
AARS Test Report 1
AARS Test Report 2
AARS Test Report 3
exp. Service Inc. PUB-DRU292547
PUB-DRU285762
PUB-DRU285764
IKO Industries Ltd. Modiflex MP-180 F/S 1 Tested System
1 Tested System
1 Tested System
----
----
----
-4.80
-2.40
-4.20
----
----
----
-100.00
-50.00
-87.00
Steel
Steel
Steel
AARS Test Report 1
AARS Test Report 2
AARS Test Report 3
exp. Service Inc. PUB-DRU292547
PUB-DRU285762
PUB-DRU285764
IKO Industries Ltd. Modiflex MP-180 SS 1 Tested System
1 Tested System
1 Tested System
----
----
----
-4.80
-2.40
-4.20
----
----
----
-100.00
-50.00
-87.00
Steel
Steel
Steel
AARS Test Report 1
AARS Test Report 2
AARS Test Report 3
exp. Service Inc. PUB-DRU292547
PUB-DRU285762
PUB-DRU285764
IKO Industries Ltd. Torchflex TP-180 FF 1 Tested System
1 Tested System
1 Tested System
----
----
----
-4.80
-2.40
-4.20
----
----
----
-100.00
-50.00
-87.00
Steel
Steel
Steel
AARS Test Report 1
AARS Test Report 2
AARS Test Report 3
exp. Service Inc. PUB-DRU292547
PUB-DRU285762
PUB-DRU285764
Soprema Inc. Elastophene 180 S 1 Tested System
1 Tested System
----
----
-3.0
-2.40
----
----
-63.00
-50.00
Steel
Steel
AARS Test Report 4
AARS Test Report 5
exp. Service Inc. PUB-DRU212868
PUB-DRU210983
Soprema Inc. Sopralene 180 S 1 Tested System
1 Tested System
1 Tested System
----
----
----
-3.00
-2.40
-3.00
----
----
----
-63.00
-50.00
-62.00
Steel
Steel
Steel
AARS Test Report 4
AARS Test Report 5
AARS Test Report 9
exp. Service Inc. PUB-DRU212868
PUB-DRU210983
PUB-DRU229544
Soprema Inc. Colply Base 410 1 Tested System ---- -2.40 ---- -50.00 Steel AARS Test Report 5 exp. Service Inc. PUB-DRU210983
Soprema Inc. Elastophene 180 PS 1 Tested System
1 Tested System
1 Tested System
----
----
----
-3.00
-2.40
-3.00
----
----
----
-63.00
-50.00
-62.00
Steel
Steel
Steel
AARS Test Report 4
AARS Test Report 5
AARS Test Report 9
exp. Service Inc. PUB-DRU212868
PUB-DRU210983
PUB-DRU229544
Soprema Inc. Elastophene PS 1 Tested System
1 Tested System
1 Tested System
----
----
----
-3.00
-2.40
-3.00
----
----
----
-63.00
-50.00
-62.00
Steel
Steel
Steel
AARS Test Report 4
AARS Test Report 5
AARS Test Report 9
exp. Service Inc. PUB-DRU212868
PUB-DRU210983
PUB-DRU229544
Soprema Inc. Elastophene Flam 1 Tested System
1 Tested System
1 Tested System
2 Tested Systems
3 Tested Systems
2 Tested Systems
----
----
----
-3.40
-2.40
-1.90
-4.30
-2.70
-4.30
-4.80
-4.60
-3.90
----
----
----
-72.00
-50.00
-40.00
-87.30
-55.50
-90.00
-100.00
-96.00
-83.00
Steel
Steel
Steel
Steel
Steel
Steel
AARS Test Report 1
AARS Test Report 2
AARS Test Report 7
AARS Test Report 8
AARS Test Report 10
AARS Test Report 11
exp. Service Inc. RP-DRU210754
RAP-DRU240663
PUB-DRC303964
PUB-DRU240661
PUB-DRU229544
PUB-DRU220544
Soprema Inc. Sopraflash Flam Stick 1 Tested System ---- -3.00 ---- -63.00 Steel AARS Test Report 6 exp. Service Inc. PUB-DRU209338
Soprema Inc. Sopralene 180 PS 1 Tested System
1 Tested System
1 Tested System
----
----
----
-3.00
-2.40
-3.0
----
----
----
-63.00
-50.00
-62.00
Steel
Steel
Steel
AARS Test Report 4
AARS Test Report 5
AARS Test Report 9
exp. Service Inc. PUB-DRU212868
PUB-DRU210983
PUB-DRU229544
Soprema Inc. Sopralene 250 S 1 Tested System
1 Tested System
----
----
-3.00
-2.40
----
----
-63.00
-50.00
Steel
Steel
AARS Test Report 4
AARS Test Report 5
exp. Service Inc. PUB-DRU212868
PUB-DRU210983
Soprema Inc. Sopralene Flam 180 1 Tested System
1 Tested System
1 Tested System
2 Tested Systems
1 Tested System
3 Tested Systems
2 Tested Systems
----
----
----
-3.40
----
-2.40
-1.90
-4.30
-2.70
-4.30
-4.80
-3.00
-4.60
-3.90
----
----
----
-72.00
----
-50.00
-40.00
-87.30
-55.50
-90.00
-100.00
-62.00
-96.00
-83.00
Steel
Steel
Steel
Steel
Steel
Steel
Steel
AARS Test Report 1
AARS Test Report 2
AARS Test Report 7
AARS Test Report 8
AARS Test Report 9
AARS Test Report 10
AARS Test Report 11
exp. Service Inc. RP-DRU210754
RAP-DRU240663
PUB-DRC303964
PUB-DRU240661
PUB-DRU228011
PUB-DRU229544
PUB-DRU220544
Soprema Inc. Sopralene Flam 250 1 Tested System
1 Tested System
1 Tested System
2 Tested Systems
1 Tested System
3 Tested Systems
2 Tested Systems
----
----
----
-3.40
---
-2.40
-1.90
-4.30
-2.70
-4.30
-4.80
-3.00
-4.60
-3.90
----
----
----
-72.00
----
-50.00
-40.00
-87.30
-55.50
-90.00
-100.00
-62.00
-96.00
-83.00
Steel
Steel
Steel
Steel
Steel
Steel
Steel
AARS Test Report 1
AARS Test Report 2
AARS Test Report 7
AARS Test Report 8
AARS Test Report 9
AARS Test Report 10
AARS Test Report 11
exp. Service Inc. RP-DRU210754
RAP-DRU240663
PUB-DRC303964
PUB-DRU240661
PUB-DRU228011
PUB-DRU229544
PUB-DRU220544
Soprema Inc. Sopraply Base 510 1 Tested System ---- -3.00 ---- -62.00 Steel AARS Test Report 9 exp. Service Inc. PUB-DRU228011
Soprema Inc. Sopraply Base 520 1 Tested System
1 Tested System
1 Tested System
2 Tested Systems
3Tested Systems
2 Tested Systems
----
----
----
-3.40
-2.40
-1.90
-4.30
-2.70
-4.30
-4.80
-4.60
-3.90
----
----
----
-72.00
-50.00
-40.00
-87.30
-55.50
-90.00
-100.00
-96.00
-83.00
Steel
Steel
Steel
Steel
Steel
Steel
AARS Test Report 1
AARS Test Report 2
AARS Test Report 7
AARS Test Report 8
AARS Test Report 10
AARS Test Report 11
exp. Service Inc. RP-DRU210754
RAP-DRU240663
PUB-DRC303964
PUB-DRU240661
PUB-DRU229544
PUB-DRU220544