Difference between revisions of "Template:MARS Membrane - SBS 2-Ply Base"
Difference between revisions of "Template:MARS Membrane - SBS 2-Ply Base"
Line 9: | Line 9: | ||
{| class="wikitable" style="margin-left: 20pt; margin-right: auto; border-color:#E7E9E9;" | {| class="wikitable" style="margin-left: 20pt; margin-right: auto; border-color:#E7E9E9;" | ||
|+ | |+ | ||
− | ! colspan="2" rowspan="1"; style="vertical-align:center;text-align:center; background-color:#a2a9b1" | Primary Material !! rowspan="6" | + | ! colspan="2" rowspan="1"; style="vertical-align:center;text-align:center; background-color:#a2a9b1" | Primary Material !! rowspan="6" style="border:none; background-color:#E7E9E9;" | |
− | ! colspan="4" rowspan="1"; style="vertical-align:center;text-align:center; background-color:#a2a9b1" | Secondary Materials & Deck !! rowspan="6" | + | ! colspan="4" rowspan="1"; style="vertical-align:center;text-align:center; background-color:#a2a9b1" | Secondary Materials & Deck !! rowspan="6" style="border:none; background-color:#E7E9E9;" | |
! colspan="8" rowspan="1"; style="vertical-align:center;text-align:center; background-color:#a2a9b1" | Tested Assembly Report Data | ! colspan="8" rowspan="1"; style="vertical-align:center;text-align:center; background-color:#a2a9b1" | Tested Assembly Report Data | ||
|- | |- |
Revision as of 18:32, 28 June 2018
- How to use the table
- In the table below look for maximum wind uplift values that exceed the requirements determined through the RCI calculator;
(NOTE: while the reports show two different values for tested maximum assembly strength, the RPM tables display only the values adjusted for the required safety factor of 1.5) - Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report. It will break down the assembly by its components. Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the RoofStar Guarantee Program (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer);
- In cases where a tested Secondary material is not accepted by the RoofStar Guarantee Program, look for alternates which often are published in the each report. In the absence of published alternates, locate a possible alternate in the Accepted Materials section of this Manual and consult the listed manufacturer for written approval.
Primary Material | Secondary Materials & Deck | Tested Assembly Report Data | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer | Membrane | Insulation Overlay |
Insulation | Deck Overlay |
Deck | Tested Systems |
kPa | Psf | Downloadable Test Report |
Test Facility | Test Facility Report No. | ||||
Low | High | Low | High | ||||||||||||
IKO Industries Ltd. | Fast-N-Stick-180 Base | ---- | ---- | ---- | Steel | 2 | -1.90 | -4.8 | -40.00 | -100.00 | MARS Test Report 1 | exp. Service Inc. | PUB-DRU292551 | ||
IKO Industries Ltd. | Fast-N-Stick HD Base | ---- | ---- | ---- | Steel | 3 | -2.40 | -5.10 | -50.00 | -106.00 | MARS Test Report 2 | exp. Service Inc. | PUB-DRU285771 | ||
Soprema Inc. | Soprafix Base 630 | ---- | ---- | ---- | Steel | 4 1 3 4 |
-2.00 --- -1.60 -2.00 |
-6.20 -2.40 -3.20 -6.20 |
-42.00 --- -33.00 -42.00 |
-130.00 -50.00 -67.00 -130.00 |
MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 10 |
exp. Service Inc. | PUB-DRU168540 PUB-DRU168534 PUB-DRU206751 PUB-DRU339156 |