Difference between revisions of "Materials:(Marine) MR/S-150"
Difference between revisions of "Materials:(Marine) MR/S-150"
Line 1: | Line 1: | ||
__NOTOC__ | __NOTOC__ | ||
__NONUMBEREDHEADINGS__ | __NONUMBEREDHEADINGS__ | ||
+ | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
+ | |||
+ | <big><big>Division C - Accepted Materials</big></big> | ||
+ | <hr> | ||
+ | <big><big><big><big><big>MR/S-150 (metal panel)</big></big></big></big></big><br> | ||
+ | <big><big><big>by Marine Roofing (1996) Ltd.</big></big></big><br> | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
− | | style="background-color: # | + | | style="background-color:#FFFACD" | '''<big>Material Acceptance and Product Details</big>''' |
− | + | <br> | |
− | + | The information published in the RCABC '''''Roofing Practices Manual''''' and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this material recommended or endorsed by the ''Guarantor''. The preparation of a detailed specification is the responsibility of the ''Design Authority''. | |
|- | |- | ||
− | | | + | | |
+ | ;: | ||
;'''Manufacturer''': Marine Roofing (1996) Ltd. | ;'''Manufacturer''': Marine Roofing (1996) Ltd. | ||
;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] | ;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] |
Revision as of 20:26, 28 October 2022
Division C - Accepted Materials
MR/S-150 (metal panel)
by Marine Roofing (1996) Ltd.
Material Acceptance and Product Details
|
The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. |
OVERVIEW
The New Tech Machinery Panel Machine is an on-site continuous panel metal roofing machine. This machine produces MR/S-150 panels with a seam height of 38 mm (1-1/2"). Panel profiles vary from 300 mm (12") to 500mm (20") wide.
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to nominal 46 m (150').
SYSTEM DESCRIPTION
- General: Standing seam panels use a hidden fastening clip system for mechanical fastening to a solid substrate. The maximum spacing of the clips is 600 mm (24") on centre. The panels are locked together with the clips as part of the seam, by use of a mechanical seamer.
- Range of application: on wood or metal sloped roofs with or without exterior insulation; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
- Fasteners (Screws): Fasteners used to attach panel clips to steel to be No. 10-16 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated screw. Minimum two fasteners per clip to be used.
- Panel Clips: One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022". (No. 22 MSG). Clips spaced 600 mm (24") on centre fastened to plywood deck. Englert "series 1000 Interlocking Clip".
- Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.
PROFILE
N/A
TECHNICAL DATA SHEET
N/A
SITE CONDITIONS
- Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
PERFORMANCE REQUIREMENTS
- Wind Uplift Standards: Engineered designs to resist wind uplift may refer to the British Columbia Building Code, Div. B, Appendix C, Table C-2 which lists various types of loads, including wind loads, for specific reference locations throughout the province. See also Guides and Notes (Wind Resistance) for a simplified calculation procedure. Regardless of the resources indicated here, the Design Authority is responsible to perform accurate wind load calculations and specify securement requirements.
- Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the standards published in the Standard for Architectural Sheet Metal (ASM) Systems.