Materials:(Bothwell-Accurate) BA-Versaspan 200 (SS 200)
Materials:(Bothwell-Accurate) BA-Versaspan 200 (SS 200)
The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program. |
The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. |
OVERVIEW
The SS 200 (BA-Versaspan 200) standing seam panel is formed with an on-site / in-shop continuous metal roofing panel roll forming machine NTM-SSQ. This machine produces a standing seam panel with a seam height of 50.8mm (2") and profiles can vary from 305mm (12") wide up to 508mm (18") wide. This machine also produces BA-Versaspan1 (SS100), BA-Versaspan1.5 (SS150), BA-Versaclip (SS675), and BA-Versasnap (FF100).
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lenghts up to 200' plus.
SYSTEM DESCRIPTION
- General: The BA-Versaspan1 (SS100) is a standing seam concealed fastener roof panel. The panel is attached with clips to allow for expansion and contraction. The maximum spacing of the clips and fasteners are 76.2mm (3').
- Range of application: Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction. Considered a traditional standing seam panel.
- Fasteners (Screws): Fasteners used to attach panel clips to plywood to be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used.
- Roof Deck Fasteners (Panel Clips): One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 900 mm (36") O.C., fastened to plywood deck.
- Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.
PROFILE
BA-Versaspan 1 (SS 100) Standing Seam Panel |
---|
TECHNICAL DATA SHEET
Click below for the Technical Data Sheet
SITE CONDITIONS
Minimum roof slope is 1:12 (1" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:4 (3" in 12").
PERFORMANCE REQUIREMENTS
- Wind Uplift Standards: Engineered designs to resist wind uplift may refer to the British Columbia Building Code, Div. B, Appendix C, Table C-2 which lists various types of loads, including wind loads, for specific reference locations throughout the province. See also Guides and Notes (Wind Resistance) for a simplified calculation procedure. Regardless of the resources indicated here, the Design Authority is responsible to perform accurate wind load calculations and specify securement requirements.
- Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the standards published in the Standard for Architectural Sheet Metal (ASM) Systems.