Working Page 10
Working Page 10
Revision as of 22:14, 2 February 2026 by James Klassen (talk | contribs)
- Division D - Construction Details
- Construction Details for Architectural Sheet Metal (ASM) Roof Systems
- The drawings linked on this page are intended to represent a variety of ASM roof system applications while remaining generic with regards to manufacturer's specific application specifications. They do not represent all possible manufacturer application roof system designs. Consult each manufacturer's specifications and the RoofStar Guarantee Standards to develop a system acceptable to both the manufacturer and the RoofStar Guarantee Program.
- For further information about Architectural Sheet Metal Roof System designs and requirements, see the Standard for Architectural Sheet Metal (ASM) Roof Systems.
Part 6 - Air and Vapour Controls
Continuity and Support ( Article 6.3.2.1.)
Part 8 - Eave, Valley, and Field Underlayment
Eave Protection/Underlayment (Slopes 1:3 or More) ( Article 8.3.2.1. and Article 8.3.2.3.)
Eave Protection/Underlayment (Slopes Less Than 1:3) ( Article 8.3.2.1. and Article 8.3.2.4.)
Part 9 - Roof Field (Panel Systems)
Panels Over Ventilation Materials or Voids: Slopes ≥ 1:6 to < 1:3 ( Article 9.3.2.5.)
- Uninsulated Assembly, Standard Clip - Drawings here (2 views)
- Uninsulated Assembly, Tall Clip - Drawings here (2 views)
- Insulated Assembly, Standard Clip on EPDM pad - Drawings here (2 views)
- Insulated Assembly, Tall Clip on Bearing Plate - Drawings here (2 views)
- Insulated Assembly, Tall Clip on Girt Supported by Thermally Non-conductive Clip - Drawings here (2 views)
- Insulated Assembly, Tall Clip on Girt - Drawings here (2 views)
Part 9 (Continued)
Panels Over Ventilation Materials or Voids: Slopes ≥ 1:3 ( Article 9.3.2.5.)
- Note: ventilation space below panels on slopes ≥ 1:3 is recommended but is not required.
- Uninsulated Assembly, Standard Clip - Drawings here (2 views)
- Uninsulated Assembly, Tall Clip - Drawings here (2 views)
- Insulated Assembly, Standard Clip on EPDM pad - Drawings here (2 views)
- Insulated Assembly, Tall Clip on Bearing Plate - Drawings here (2 views)
- Insulated Assembly, Tall Clip on Girt Supported by Thermally Non-conductive Clip - Drawings here (2 views)
- Insulated Assembly, Tall Clip on Girt - Drawings here (2 views)
Part 10 - Perimeters and Valleys
Roof-Wall Connections ( Article 10.3.2.3.)
Ridges ( Article 10.3.4.1.)
Eave and Rake Edge Details ( Article 10.3.4.2.)
- Eave and Rake Edges (Mechanical Seams)
- Eave and Rake Edges (Snap-Lock Seams)
- Eave and Rake Edges (Copper)
- Eave and Rake Edges (Zinc)
Valleys ( Article 10.3.5.2.)
Part 11 - Drainage
Membrane Gutters ( Article 11.3.3.8.)
Part 12 - Penetrations and Curbs
Penetration Flashing ( Article 12.3.2.1.)
Curbs ( Article 12.3.2.4.)
Part 13 - Linear Metal Flashing
© RCABC 2026
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.
