The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program.
Manufacturer
Bothwell-Accurate Company (B.C.) Ltd.
Contact Address
See the current Membership list and contact information at www.rcabc.org
Product Group - Standing Seam Metal Roof System
Panel Machine
New Tech
Panel Name
BA-Versaspan 200 (SS 200)
Accepted for the RoofStar Guarantee Program
2021-June-17
Seam Type
Mechanical Lock (50.8 mm) (2")

The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer.

OVERVIEW

The BA-Versaspan 200 (SS 200) standing seam panel is formed with an on-site / in-shop continuous metal roofing panel roll forming machine NTM-SSQ. This machine produces a standing seam panel with a seam height of 50.8 mm (2") and profiles can vary from 305 mm (12") wide up to 508 mm (18") wide. This machine also produces BA-Versaspan 100 (SS 100), BA-Versaspan 150 (SS 150), BA-Versaclip (SS 675), and BA-Versasnap (FF 100).

On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to 200' plus.

SYSTEM DESCRIPTION

  1. General: The BA-Versaspan 200 (SS 200) is a concealed fastener standing seam roof panel. The panel is attached with clips to allow for expansion and contraction.
  2. Range of application: Installed on wood or steel sloped roofs in commercial, instititutional, industural, and residential construction. Ideal for low slope applications because of the 2" (50.8mm) tall seam height.
  3. Fasteners (Screws): Fasteners are fixed through clips that hook onto the male leg of the panel. Minimum two fasteners per clip to be used. Spacing is site specific, engineer must confirm fastening specifications.
  4. Roof Deck Fasteners (Panel Clips): Refer to manufacturer for clip details and spacing.
  5. Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.

PROFILE

BA-Versaspan 200 (SS 200) Standing Seam Panel
BA-Versaspan 200 (SS 200) Panel.jpg

TECHNICAL DATA SHEET

Click below for the Technical Data Sheet

Technical Data Sheet

SITE CONDITIONS

Fabricated panels (on site if necessary) in one continuous length to suit site requirments. This 2" tall seam height panel is highly recommend for use on slopes less than 3"/12"

PERFORMANCE REQUIREMENTS

  1. Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
  2. Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.