Search results
Search results
Create the page "Section:D. Low Slope Roofs" on this wiki! See also the search results found.
- ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==416 KB (56,532 words) - 22:23, 5 April 2024
- ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==424 KB (57,417 words) - 17:24, 28 May 2024
- ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==421 KB (57,062 words) - 22:20, 5 April 2024
- ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==296 KB (41,811 words) - 22:23, 5 April 2024
- ...e less than the percentage of slope provided by the insulation. A minimum slope of 1:50 (1/4" in 12") is strongly recommended. The exception is often drain ...r bearing walls. Building settlement can often cause slopes to change and low spots to appear on the roof surface.20 KB (2,969 words) - 16:06, 9 September 2021
- [[Section:D. Application: Low Slope Roofs|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''EPDM Application''] [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back1,011 bytes (124 words) - 21:30, 16 September 2016
- *low temperature flexibility ...aminated with metal foil for ultra-violet protection. As an alternative on roofs with minimal slopes, a pour coat and gravel surfacing may be installed over23 KB (3,307 words) - 15:57, 9 September 2021
- [[Section:D. Application: Low Slope Roofs|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''TPO/PVC Application [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back1 KB (128 words) - 15:20, 19 September 2016
- This section has been reprinted with the kind permission of: Many of the remarks in this section pertain to bituminous built-up roofs. However, data is also included on flexible membrane (“non-convention75 KB (11,617 words) - 21:00, 3 September 2021
- ...ng ''deck'' structure (adapted from ''ASTM D6630-08 Standard Guide for Low slope Insulated Roof membrane Assembly Performance''). ...cle 3.1.3.4. in any of the waterproofing roof Standards for sheet membrane roofs, published in Division B of the RPM).76 KB (11,565 words) - 18:09, 26 January 2024
- * improved low temperature flexibility ...fs|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Application: Low Slopes'']]1 KB (189 words) - 18:41, 4 January 2016
- ...fs|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Application: Low Slopes'']]128 bytes (18 words) - 18:49, 4 January 2016
- ...fs|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Application: Low Slopes'']]128 bytes (18 words) - 18:53, 4 January 2016
- [[:Section:A. About|'''A. About''']] [[:Section:B. Essential Elements|'''B. Essential Elements''']]7 KB (990 words) - 20:54, 2 August 2016
- '''NOTE''': This page is under development. Refer to the [[Section:G. Construction Details|'''SBS, EPDM or TPO/PVC Membrane Construction Detai [[Section:D. Application: Low Slope Roofs|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Other Flexible Memb696 bytes (92 words) - 01:13, 15 September 2016
- Contact Address: See Membership List in Section 1. # Slope: Roof slopes which exceed ½" in 12" (4.2%) require the following:21 KB (3,147 words) - 19:39, 7 November 2016
- Contact Address: See Membership List in Section 1. # Used in new construction and re-roofing of existing roofs.20 KB (3,027 words) - 23:04, 7 November 2016
- ...amenity space is installed on top of it. An integrity scan typically uses low-voltage electrical current to detect even the smallest breaches in the roof :Electronic Leak Detection (ELD) utilizes low-voltage electrical current, typically conducted through wires installed in59 KB (8,538 words) - 18:07, 2 April 2024
- ...amenity space is installed on top of it. An integrity scan typically uses low-voltage electrical current to detect even the smallest breaches in the roof :Electronic Leak Detection (ELD) utilizes low-voltage electrical current, typically conducted through wires installed in57 KB (8,227 words) - 18:02, 2 April 2024
- ...amenity space is installed on top of it. An integrity scan typically uses low-voltage electrical current to detect even the smallest breaches in the roof :Electronic Leak Detection (ELD) utilizes low-voltage electrical current, typically conducted through wires installed in57 KB (8,227 words) - 18:07, 2 April 2024