Difference between revisions of "Materials:(Bothwell-Accurate) BA-Versasnap (FF 100)"

Jump to: navigation, search

Difference between revisions of "Materials:(Bothwell-Accurate) BA-Versasnap (FF 100)"

(SYSTEM DESCRIPTION)
(PERFORMANCE REQUIREMENTS)
 
(13 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
__NOTOC__
 
__NOTOC__
 
__NONUMBEREDHEADINGS__
 
__NONUMBEREDHEADINGS__
 +
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
 +
 +
<big><big>Division C - Accepted Materials</big></big>
 +
<hr>
 +
<big><big><big><big><big>BA Versasnap (FF 100)</big></big></big></big></big><br>
 +
<big><big><big>by Bothwell-Accurate Company (B.C.) Ltd.</big></big></big><br>
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 13: Line 19:
 
;'''Panel Machine''': New Tech  
 
;'''Panel Machine''': New Tech  
 
;'''Panel Name''': BA-Versasnap (FF 100)
 
;'''Panel Name''': BA-Versasnap (FF 100)
;'''Seam Type''': Snap Lock
+
;'''Seam Type''': Snap Lock (Flange-fastened)
  
 
The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.  For more information about this product or system, consult the manufacturer.
 
The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.  For more information about this product or system, consult the manufacturer.
Line 19: Line 25:
  
 
====OVERVIEW====
 
====OVERVIEW====
The FF100 (BA-Versasnap) standing seam panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine ( New Tech SS Multipro ). This machine produces a standing seam panel with a seam height of 23.4mm (7/8") and profiles can vary from 305mm (12") wide up to 635mm (24") wide. This machine also produces SS675 (BA-Versaclip), SS100 (BA-Versaspan1), SS150 (BA-Versaspan1.5).
+
The FF 100 (BA-Versasnap) standing seam panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine ( New Tech SS Multipro ). This machine produces a standing seam panel with a seam height of 23.4 mm (7/8") and profiles can vary from 305 mm (12") wide up to 635 mm (24") wide. This machine also produces SS 675 (BA-Versaclip), SS 100 (BA-Versaspan 100), SS 150 (BA-Versaspan 150).
  
 
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to 200' plus (depending on coil size and handling/maneuvering.
 
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to 200' plus (depending on coil size and handling/maneuvering.
  
 
====SYSTEM DESCRIPTION====
 
====SYSTEM DESCRIPTION====
#'''General''': The BA-Versasnap (FF100) is standing seam concealed fastener roof panel. The maximum spacing of screws in the built in nailing strip is 635mm (24")
+
#'''General''': The BA-Versasnap (FF 100) is standing seam concealed fastener roof panel. The maximum spacing of screws in the built-in nailing strip (flange) is 635 mm (24")
 
#'''Range of application''': Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction.
 
#'''Range of application''': Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction.
 
#'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications.
 
#'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications.
 
#'''Fasteners (Screws)''': Fasteners used to attach panel clips to plywood to be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used.  
 
#'''Fasteners (Screws)''': Fasteners used to attach panel clips to plywood to be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used.  
 
#'''Panel Clips''': One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 900 mm (36") O.C., fastened to plywood deck.
 
#'''Panel Clips''': One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 900 mm (36") O.C., fastened to plywood deck.
 +
#'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].
  
 
====PROFILE====
 
====PROFILE====
Line 35: Line 42:
 
! BA-Versasnap (FF 100) Standing Seam Panel
 
! BA-Versasnap (FF 100) Standing Seam Panel
 
|-
 
|-
| [[File:BA-Versasnap (FF 100) Panel.jpg|frameless|link=Architectural Metal Roofing|750px]]
+
| [[File:BA-Versasnap FF 100 Panel.jpg|frameless|link=https://rpm.rcabc.org/images/f/f0/BA-Versasnap_FF_100_Panel.jpg|750px]]
 
|}
 
|}
  
Line 42: Line 49:
  
 
<div style="width:150px; text-align: left;">
 
<div style="width:150px; text-align: left;">
[[File:Pdf.png|75 px|link=http://rpm.rcabc.org/images/8/81/BA_-_Versasnap_%28FF_100%29_TDS.pdf|'''Technical Data Sheet''']]
+
[[File:Pdf.png|75 px|link=https://rpm.rcabc.org/images/8/87/BA_VERSASNAP_FF_100_STANDING_SEAM_TDS.pdf|'''Technical Data Sheet''']]
 
</div>
 
</div>
  
Line 49: Line 56:
  
 
====PERFORMANCE REQUIREMENTS====
 
====PERFORMANCE REQUIREMENTS====
#'''Wind Uplift Standards''': Engineered designs to resist wind uplift may refer to the British Columbia Building Code, Div. B, Appendix C, Table C-2 which lists various types of loads, including wind loads, for specific reference locations throughout the province. See also [http://{{SERVERNAME}}/index.php?title=ASM_Application_Guides_and_Notes Guides and Notes (Wind Resistance)] for a simplified calculation procedure. Regardless of the resources indicated here, the Design Authority is responsible to perform accurate wind load calculations and specify securement requirements.
+
<ol>
#'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the standards published in the [http://rpm.rcabc.org/index.php/RoofStar_Guarantee_Standards_for_ASM_Roof_Assemblies Architectural Sheet Metal (ASM) Roof Standards].
+
<li>'''Wind Uplift Resistance''': Panel securement shall conform to the requirements in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#PART_3 Part 3] of the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].
 +
<li>'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#Section_9.2._Materials Section 9.2.] of the Standard.
 +
</li></ol>
  
 
<hr>
 
<hr>

Latest revision as of 17:07, 26 October 2023



Division C - Accepted Materials


BA Versasnap (FF 100)
by Bothwell-Accurate Company (B.C.) Ltd.

The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program.
Manufacturer
Bothwell-Accurate Company (B.C.) Ltd.
Contact Address
See the current Membership list and contact information at www.rcabc.org
Product Group - Standing Seam Metal Roof System
Panel Machine
New Tech
Panel Name
BA-Versasnap (FF 100)
Seam Type
Snap Lock (Flange-fastened)

The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer.

OVERVIEW

The FF 100 (BA-Versasnap) standing seam panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine ( New Tech SS Multipro ). This machine produces a standing seam panel with a seam height of 23.4 mm (7/8") and profiles can vary from 305 mm (12") wide up to 635 mm (24") wide. This machine also produces SS 675 (BA-Versaclip), SS 100 (BA-Versaspan 100), SS 150 (BA-Versaspan 150).

On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to 200' plus (depending on coil size and handling/maneuvering.

SYSTEM DESCRIPTION

  1. General: The BA-Versasnap (FF 100) is standing seam concealed fastener roof panel. The maximum spacing of screws in the built-in nailing strip (flange) is 635 mm (24")
  2. Range of application: Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction.
  3. Panel Attachment: Fastening is site specific, engineer must confirm fixing specifications.
  4. Fasteners (Screws): Fasteners used to attach panel clips to plywood to be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used.
  5. Panel Clips: One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 900 mm (36") O.C., fastened to plywood deck.
  6. Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.

PROFILE

BA-Versasnap (FF 100) Standing Seam Panel
BA-Versasnap FF 100 Panel.jpg

TECHNICAL DATA SHEET

Click below for the Technical Data Sheet

Technical Data Sheet

SITE CONDITIONS

Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").

PERFORMANCE REQUIREMENTS

  1. Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
  2. Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.


Back to Site-Formed Metal Roofing Systems