Materials:(Bothwell-Accurate) BA-Versaspan 100 (SS 100)

Jump to: navigation, search

Materials:(Bothwell-Accurate) BA-Versaspan 100 (SS 100)

Revision as of 22:44, 13 February 2019 by James Klassen (talk | contribs) (PROFILE)


The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program.
Manufacturer
Bothwell-Accurate Company (B.C.) Ltd.
Contact Address
See the current Membership list and contact information at www.rcabc.org
Product Group - Standing Seam Metal Roof System
Panel Machine
New Tech
Panel Name
BA-Versaspan 1 (SS 100)
Seam Type
Snap Lock

The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer.

OVERVIEW

The BA-Versaspan1 (SS100) standing seam panel is formed with an on-site/in-shop continuous metal roofing panel roll forming machine (New Tech SS Multipro). This machine produces a standing seam panel with a seam height of 25.4 mm (1") and profiles can vary from 330.2mm (13") wide up to 533.4mm (21") wide. This machine also produces FF100 (BA-Versasnap), SS675 (BA-Versaclip), SS150 (BA-Versaspan1.5) On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to 200' plus (depending on coil size and handling/maneuvering.

SYSTEM DESCRIPTION

  1. General: The BA-Versaspan1 (SS100) is a standing seam concealed fastener roof panel. The panel is attached with clips to allow for expansion and contraction. The maximum spacing of the clips and fasteners are 76.2mm (3').
  2. Range of application: Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction. Considered a traditional standing seam panel.
  3. Fasteners (Screws): Fasteners used to attach panel clips to plywood to be No. 10-12 by 25 mm (1") long pancake head, No. 2 Phillips drive, A-point, coated steel screw. Minimum two fasteners per clip to be used.
  4. Roof Deck Fasteners (Panel Clips): One piece assembly 43.75 mm (1-3/4") wide, 31 mm (1-1/4") high. Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 900 mm (36") O.C., fastened to plywood deck.

PROFILE

BA-Versaspan 1 (SS 100) Standing Seam Panel
BA-Versaspan (SS 100) Panel.jpg

TECHNICAL DATA SHEET

Click below for the Technical Data Sheet

Technical Data Sheet

SITE CONDITIONS

Minimum roof slope is 1:12 (1" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:4 (3" in 12").

PERFORMANCE REQUIREMENTS

  1. Wind Uplift Standards: Engineered designs to resist wind uplift may refer to the British Columbia Building Code, Div. B, Appendix C, Table C-2 which lists various types of loads, including wind loads, for specific reference locations throughout the province. See also Guides and Notes (Wind Resistance) for a simplified calculation procedure. Regardless of the resources indicated here, the Design Authority is responsible to perform accurate wind load calculations and specify securement requirements.
  2. Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the standards published in the Architectural Sheet Metal (ASM) Roof Standards.


Back to Site-Formed Metal Roofing Systems

Back to Accepted Materials


Home