  • ...ield application are presently available as a catalyzed resin that require a woven reinforcement inter-ply for strength. To ensure quality installation
    1 KB (178 words) - 21:51, 7 September 2021
  • ...the marketplace may be specified and installed in a ''project'' for which a '''''RoofStar Guarantee''''' is required – only those that satisfy the ac ...come a member of the RCABC, visit our [http://www.rcabc.org/members/become-a-member/ '''website'''].
    22 KB (3,050 words) - 16:20, 12 December 2023
  • ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...inous roofing systems. However, some systems require that applicators use a propane-fuelled open flame torch to adhere the membrane. When working with
    14 KB (2,333 words) - 16:39, 9 February 2022
  • ...; specifications and the '''''RoofStar Guarantee Standards''''' to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee <li>[[SBS Membrane Termination A | Membrane Termination A]]
    7 KB (906 words) - 16:03, 26 February 2024
  • ;(A) [[Asphalt Shingle Systems Standard#AShDECKS|'''Acceptable Deck''']]
    3 KB (343 words) - 14:29, 30 June 2022
  • ...) minimum on sides and 150 mm (6") minimum on ends. (See Section 3.1.5 for a list of accepted eave protection and underlayment.) (A) <b>Acceptable Deck</b>
    2 KB (260 words) - 22:52, 21 December 2015
  • ...equirements for side and end laps; use acceptable fasteners, or adhere (if a self-adhering membrane) in keeping with the manufacturer’s published requ ;(A) [[Asphalt Shingle Systems Standard#AShDECK|'''Acceptable Deck''']]
    3 KB (344 words) - 14:13, 5 October 2022
  • ...equirements for side and end laps; use acceptable fasteners, or adhere (if a self-adhering membrane) in keeping with the manufacturer’s published requ ;(A) [[Asphalt Shingle Systems Standard#AShDECK|'''Acceptable Deck''']]
    3 KB (351 words) - 14:11, 5 October 2022
  • <big><big><big><big><big>Asphalt Shingles | Flashing a Masonry Chimney ([[Asphalt_Shingle_Systems_Standard#12.3.2.4. Curbs | Artic
    1 KB (171 words) - 14:35, 30 June 2022
  • ...b>: Formed from a minimum 26 guage galvanized steel diverters shall extend a minimum 125 mm (5") up vertical surfaces 100 mm (4") to the roof. ...be angle trimmed and a drip edge formed at the outlet. Outlet is to extend a minimum of 25mm (1") lower than the edge of the roof material and lead wate
    1 KB (196 words) - 22:57, 21 December 2015
  • : Extended a minimum 100mm (4") beyond corners, interwoven with shingles and step flashi ;(6) '''Capillary Section''': A capillary tab is to be extended off the end of the back pan to lead water a
    2 KB (312 words) - 14:39, 30 June 2022
  • ::Click below for a printable version of this page (N/A) ...'''Hook securement strip''']]: In this particular rake edge configuration, a similar strip is installed along the rake to secure the flush rake-edge fla
    3 KB (473 words) - 18:24, 28 June 2022
  • A '''''RoofStar Guarantee''''' is available for almost any roof design, provi ...All new materials incorporated into a ''Project'' intended to qualify for a '''''RoofStar Guarantee''''' must be expressly accepted by the RGC and list
    9 KB (1,253 words) - 17:05, 10 December 2021
  • ...'''' or '''''RoofStar 15-year Guarantee'''''. Requirements to qualify for a '''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under ...ganization_of_RPM_and_Standards#2.3.1.2._Authority_and_Conflict | Division A, Article 2.3.1.2.]] shall be applied.
    416 KB (56,532 words) - 22:23, 5 April 2024
  • ...'''' or '''''RoofStar 15-year Guarantee'''''. Requirements to qualify for a '''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under ...ganization_of_RPM_and_Standards#2.3.1.2._Authority_and_Conflict | Division A, Article 2.3.1.2.]] shall be applied.
    424 KB (57,418 words) - 22:20, 5 April 2024
  • ...'''' or '''''RoofStar 15-year Guarantee'''''. Requirements to qualify for a '''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under ...ganization_of_RPM_and_Standards#2.3.1.2._Authority_and_Conflict | Division A, Article 2.3.1.2.]] shall be applied.
    421 KB (57,062 words) - 22:20, 5 April 2024
  • ...'''' or '''''RoofStar 15-year Guarantee'''''. Requirements to qualify for a '''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under ...ganization_of_RPM_and_Standards#2.3.1.2._Authority_and_Conflict | Division A, Article 2.3.1.2.]] shall be applied.
    296 KB (41,811 words) - 22:23, 5 April 2024
  • ...a fa-hand-o-right" aria-hidden="true"></i> <big>Requesting and Specifying a RoofStar Guarantees</big>]]
    643 bytes (78 words) - 18:53, 27 July 2016
  • ...SYTEMS for a RoofStar 5-year Guarantee, RoofStar 10-year Guarantee, or for a RoofStar 15-year Guarantee.</big> ...Manual''. Furthermore, these tables and lists are not intended for use as a comparison of material performance or quality. It is the sole responsibilit
    13 KB (1,636 words) - 17:02, 5 January 2024
  • ...t are not recommended or endorsed by the ''Guarantor''. The preparation of a detailed specification is the responsibility of the ''Design Authority''. ...bership list and contact information at [http://www.rcabc.org/members/find-a-member/ '''www.rcabc.org''']
    1 KB (213 words) - 14:42, 26 October 2023