Difference between revisions of "Materials:Heritage 1-1/2" Single Lock"
Difference between revisions of "Materials:Heritage 1-1/2" Single Lock"
(Created page with "__NOTOC__ __NONUMBEREDHEADINGS__ {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} <big>...") |
m (James Klassen moved page Materials:1-1/2" Single Lock to Materials:Heritage 1-1/2" Single Lock) |
||
(13 intermediate revisions by the same user not shown) | |||
Line 5: | Line 5: | ||
<big><big>Division C - Accepted Materials</big></big> | <big><big>Division C - Accepted Materials</big></big> | ||
<hr> | <hr> | ||
− | <big><big><big><big><big> | + | <big><big><big><big><big>1-1/2" Single Lock</big></big></big></big></big><br> |
− | <big><big><big>by | + | <big><big><big>by Heritage Roofing and Sheet Metal Ltd.</big></big></big><br> |
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 14: | Line 14: | ||
|- | |- | ||
| | | | ||
− | ;'''Manufacturer''': | + | ;'''Manufacturer''': Heritage Roofing and Sheet Metal Ltd. |
;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] | ;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org] | ||
;'''Product Group - Standing Seam Metal Roof System''' | ;'''Product Group - Standing Seam Metal Roof System''' | ||
− | ;'''Panel Machine''': | + | ;'''Panel Machine''': Rollformer VS-150 |
− | ;'''Panel Name''': | + | ;'''Panel Name''': 1-1/2" Single Lock |
− | ;'''Seam Type''': Mechanical Lock | + | ;'''Seam Type''': Mechanical Lock |
The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. | The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. | ||
Line 26: | Line 26: | ||
====OVERVIEW==== | ====OVERVIEW==== | ||
(The following overview is boilerplate wording and can be modified to suit the specific panel description. | (The following overview is boilerplate wording and can be modified to suit the specific panel description. | ||
− | The | + | The '''1-1/2" Single Lock''' metal panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine Rollformer VS-150. This machine produces a standing seam panel with a seam height of 38.1 mm (1-1/2"") and profiles can vary from 228.6 mm (9") wide up to 609.6 mm (24") wide (Note that the [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard Standard for Architectural Sheet Metal (ASM) Roof Systems] stipulates a maximum width of 508 mm (20") in Article 9.2.1.1.). |
− | On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities | + | On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities. Consult the manufacturer for maximum length. |
====SYSTEM DESCRIPTION==== | ====SYSTEM DESCRIPTION==== | ||
<ol> | <ol> | ||
− | <li>'''General''': The | + | <li>'''General''': The '''1-1/2" Single Lock''' metal panel is secured with concealed fastener. |
<li>'''Range of application''': Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction. | <li>'''Range of application''': Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction. | ||
<li>'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications. | <li>'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications. | ||
<li>'''Fasteners (Screws)''': | <li>'''Fasteners (Screws)''': | ||
<ol> | <ol> | ||
− | <li>Fasteners used to attach panel clips to steel must be No. | + | <li>Fasteners used to attach panel clips to steel must be No. 14 by 38.1 mm (1-1/2") long self-drilling, self-tapping pancake head plated steel screws. Use two fasteners per panel clip, inserted into panel clip guide holes. |
− | <li>Fasteners used to attach panel clips to plywood must be No. | + | <li>Fasteners used to attach panel clips to plywood must be No. 14 by 38.1 mm (1-1/2") long pancake head plated steel screws for wood. Use two fasteners per panel clip, inserted into panel clip guide holes. |
</li></ol> | </li></ol> | ||
− | <li>'''Panel Clips''': One piece assembly | + | <li>'''Panel Clips''': One piece assembly 50.8 mm (2") wide, 38.1 mm (1-1/2") high, manufactured by AMSI Supply (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.3._Resistance_to_Specified_Wind_Loads Article 3.1.3.3.] and [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.5._Submittals Article 3.1.3.5.]). |
<li>'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | <li>'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | ||
</li></ol> | </li></ol> | ||
====PROFILE==== | ====PROFILE==== | ||
− | + | {| class="wikitable" | |
+ | |- | ||
+ | ! 1-1/2" Single Lock | ||
+ | |- | ||
+ | | [[File:Heritage Roofing 1.5 Inch Single Lock Profile (Image).png|frameless|link=https://rpm.rcabc.org/images/8/88/Heritage_Roofing_1.5_Inch_Single_Lock_Profile_%28Image%29.png|750px]] | ||
+ | |} | ||
====TECHNICAL DATA SHEET==== | ====TECHNICAL DATA SHEET==== | ||
− | + | Click below for the '''Technical Data Sheet''' | |
+ | |||
+ | <div class="col-md-12"> | ||
+ | <div class="col-md-1"> | ||
+ | <div style="text-align: center;"> | ||
+ | [[File:Pdf.png|75 px|link=https://rpm.rcabc.org/images/f/ff/Heritage_1.5_Inch_Single_Lock_TDS.pdf|'''Technical Data Sheet''']] | ||
+ | Panel TDS | ||
+ | </div> | ||
+ | </div> | ||
+ | <div class="col-md-1"> | ||
+ | <div style="text-align: center;"> | ||
+ | [[File:Pdf.png|75 px|link=https://rpm.rcabc.org/images/4/48/Heritage_1.5_Inch_Single_Lock_Clip_TDS.pdf|'''Technical Data Sheet''']] | ||
+ | Panel Clip TDS | ||
+ | </div> | ||
+ | </div> | ||
+ | </div> | ||
+ | <div class="col-md-12"> | ||
+ | </div> | ||
====SITE CONDITIONS==== | ====SITE CONDITIONS==== | ||
Line 60: | Line 82: | ||
<hr> | <hr> | ||
− | |||
[[Architectural Metal Roofing|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Site-Formed Metal Roofing Systems'']] | [[Architectural Metal Roofing|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Site-Formed Metal Roofing Systems'']] |
Latest revision as of 22:30, 27 June 2024
Division C - Accepted Materials
1-1/2" Single Lock
by Heritage Roofing and Sheet Metal Ltd.
The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program. |
The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. |
OVERVIEW
(The following overview is boilerplate wording and can be modified to suit the specific panel description. The 1-1/2" Single Lock metal panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine Rollformer VS-150. This machine produces a standing seam panel with a seam height of 38.1 mm (1-1/2"") and profiles can vary from 228.6 mm (9") wide up to 609.6 mm (24") wide (Note that the Standard for Architectural Sheet Metal (ASM) Roof Systems stipulates a maximum width of 508 mm (20") in Article 9.2.1.1.).
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities. Consult the manufacturer for maximum length.
SYSTEM DESCRIPTION
- General: The 1-1/2" Single Lock metal panel is secured with concealed fastener.
- Range of application: Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction.
- Panel Attachment: Fastening is site specific, engineer must confirm fixing specifications.
- Fasteners (Screws):
- Fasteners used to attach panel clips to steel must be No. 14 by 38.1 mm (1-1/2") long self-drilling, self-tapping pancake head plated steel screws. Use two fasteners per panel clip, inserted into panel clip guide holes.
- Fasteners used to attach panel clips to plywood must be No. 14 by 38.1 mm (1-1/2") long pancake head plated steel screws for wood. Use two fasteners per panel clip, inserted into panel clip guide holes.
- Panel Clips: One piece assembly 50.8 mm (2") wide, 38.1 mm (1-1/2") high, manufactured by AMSI Supply (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, Article 3.1.3.3. and Article 3.1.3.5.).
- Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.
PROFILE
1-1/2" Single Lock |
---|
TECHNICAL DATA SHEET
Click below for the Technical Data Sheet
SITE CONDITIONS
Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
PERFORMANCE REQUIREMENTS
- Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
- Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.