Difference between revisions of "Asphalt Shingle System Details"
Difference between revisions of "Asphalt Shingle System Details"
(Created page with ":E2.7.1 Shingle Application - All Slopes :AS Details:E2.7.1 (Low Slope Shingle Application)|E2.7.1 Low Slope Shingle...") |
|||
(61 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | :[[ | + | {{Template:RPM Info}} |
− | + | ||
− | + | __NONUMBEREDHEADINGS__ | |
− | + | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | |
− | + | __NOTOC__ | |
− | + | ||
− | + | :<big><big>Division D - Construction Details</big></big> | |
− | + | :<hr> | |
− | + | :<big><big><big><big><big>Construction Details for Asphalt Shingle Roof Systems</big></big></big></big></big> | |
− | + | ||
− | + | <div class="col-md-2"> | |
− | + | :[[File:Asphalt Shingles.JPG | link=http://rpm.rcabc.org/images/8/8a/Asphalt_Shingles.JPG |175 px]] | |
+ | </div> | ||
+ | |||
+ | <div class="col-md-10"> | ||
+ | :The drawings linked on this page are intended to represent a variety of asphalt shingle roof system applications while remaining generic with regards to ''manufacturer's'' specific application specifications. They do not represent all possible ''manufacturer'' application roof system designs. Consult each ''manufacturer's'' specifications and the '''''RoofStar Guarantee Standards''''' to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee Program'''''. | ||
+ | |||
+ | :For further information about Asphalt Shingle Roof System designs and requirements, see the '''[https://rpm.rcabc.org/index.php?title=Asphalt_Shingle_Systems_Standard Standard for Asphalt Shingle Roof Systems]'''. | ||
+ | </div> | ||
+ | |||
+ | <div class="col-md-12"> | ||
+ | </div> | ||
+ | <div class="col-md-4"> | ||
+ | <hr> | ||
+ | ===Part 6 - Air and Vapour Controls=== | ||
+ | ====='''Continuity and Support''' ([[Asphalt_Shingle_Systems_Standard#6.3.2.1._Continuity_and_Support | Article 6.3.2.1.]])===== | ||
+ | <ol> | ||
+ | <li>[[Asphalt Shingles - Air and Vapour Controls | Air and Vapour Controls]] | ||
+ | </li></ol> | ||
+ | |||
+ | ===Part 9 - Roof Field (Shingle Systems)=== | ||
+ | ====='''Application (Common and Steep Slopes)''' ([[Asphalt_Shingle_Systems_Standard#9.3.2.4. General Requirements for Asphalt Shingle Application| Article 9.3.2.4.]])===== | ||
+ | |||
+ | <ol> | ||
+ | <li>[[Asphalt Shingles - Application (Common and Steep Slopes)| Application (Common and Steep Slopes)]] | ||
+ | </li></ol> | ||
+ | |||
+ | ====='''Application (Low Slopes)''' ([[Asphalt_Shingle_Systems_Standard#9.3.2.5. Application on Slopes Less Than 1:3 | Article 9.3.2.4.]])===== | ||
+ | |||
+ | <ol> | ||
+ | <li>[[Asphalt Shingles - Application (Low Slopes) | Application (Low Slopes)]] | ||
+ | </li></ol> | ||
+ | |||
+ | ====='''Changes in Slope''' ([[Asphalt_Shingle_Systems_Standard#9.3.2.7. Changes in Slope | Article 9.3.2.7.]])===== | ||
+ | |||
+ | <ol> | ||
+ | <li>[[Asphalt Shingles - Changes in Slope (Inside Angle) | {{hilite | Changes in Slope (Inside Angle) || 2020-October-21 }}]] | ||
+ | <li>[[Asphalt Shingles - Changes in Slope (Outside Angle) | {{hilite | Changes in Slope (Outside Angle) || 2020-October-21 }}]] | ||
+ | </li></ol> | ||
+ | |||
+ | </div> | ||
+ | <div class="col-md-4"> | ||
+ | <hr> | ||
+ | |||
+ | ===Part 10 - Perimeters and Valleys=== | ||
+ | ====='''Eave and Rake Edge Details''' ([[Asphalt_Shingle_Systems_Standard#10.3.4.2._Eaves_and_Rake_Edges | Article 10.3.4.2.]])===== | ||
+ | <ol> | ||
+ | <li>[[Asphalt Shingles - Eaves (All Slopes) | Eaves (All Slopes)]] | ||
+ | <li>[[Asphalt Shingles - Diverter Flashing | {{hilite | Diverter Flashing || 2020-October-21 }}]] | ||
+ | </li></ol> | ||
+ | |||
+ | ====='''Valleys''' ([[Asphalt_Shingle_Systems_Standard#10.3.5.2._General_Requirements_for_Valley_Metal_Flashing | Article 10.3.5.2.]])===== | ||
+ | |||
+ | <ol> | ||
+ | <li>[[Asphalt Shingles - Open Valley | Open Valley]] | ||
+ | <li>[[Asphalt Shingles - Closed (Cut) Valley| Closed (Cut) Valley]] | ||
+ | <li>[[Asphalt Shingles - Woven Valley| Woven Valley]] | ||
+ | </li></ol> | ||
+ | |||
+ | ====='''Valley Intersections with Ridge''' ([[Asphalt_Shingle_Systems_Standard#10.3.5.9. Valley Intersection with Ridge | Article 10.3.5.9.]])===== | ||
+ | |||
+ | <ol> | ||
+ | <li>[[Asphalt Shingles - Valley Intersection with Ridge | Valley Intersection with Ridge]] | ||
+ | </li></ol> | ||
+ | |||
+ | ====='''Intersections with Waterproofing Roof Systems''' ([[Asphalt_Shingle_Systems_Standard#10.3.7.2. Intersections with Waterproofing Roof Systems | Article 10.3.7.2.]])===== | ||
+ | |||
+ | <ol> | ||
+ | <li>[[Asphalt Shingles - Intersection with Waterproofing Roof (Upper)| Intersection with Waterproofing Roof (Upper)]] | ||
+ | <li>[[Asphalt Shingles - Intersection with Waterproofing Roof (Lower)| Intersection with Waterproofing Roof (Lower)]] | ||
+ | </li></ol> | ||
+ | |||
+ | </div> | ||
+ | <div class="col-md-4"> | ||
+ | <hr> | ||
+ | |||
+ | ===Part 11 - Drainage=== | ||
+ | ====='''Membrane Gutters''' ([[Asphalt_Shingle_Systems_Standard#11.3.3.8._Membrane_Gutters | Article 11.3.3.8.]])===== | ||
+ | |||
+ | <ol> | ||
+ | <li>[[Asphalt Shingles - Membrane Gutter (Design Elements)| Membrane Gutter (Design Elements)]] | ||
+ | </li></ol> | ||
+ | |||
+ | ===Part 12 - Penetrations and Curbs=== | ||
+ | ====='''Penetration Flashing''' ([[Asphalt_Shingle_Systems_Standard#12.3.2.1._General_Requirements_for_Flashing_Penetrations | Article 12.3.2.1.]])===== | ||
+ | |||
+ | <ol> | ||
+ | <li>[[Asphalt Shingles - Cylindrical Penetration (Lead Flashing)| Cylindrical Penetration (Lead Flashing)]] | ||
+ | <li>[[Asphalt Shingles - Cylindrical Penetration (Flashing, Storm Collar) | {{hilite | Cylindrical Penetration (Flashing, Storm Collar)|| 2022-February-5 }}]] | ||
+ | </li></ol> | ||
+ | |||
+ | ====='''Curbs''' ([[Asphalt_Shingle_Systems_Standard#12.3.2.4._Curbs_and_Sleepers | Article 12.3.2.4.]])===== | ||
+ | |||
+ | <ol> | ||
+ | <li>[[Asphalt Shingles - Curb Flashing (Typical) | Curb Flashing (Typical)]] | ||
+ | <li>[[Asphalt Shingles - Flashing a Masonry Chimney| Flashing a Masonry Chimney]] | ||
+ | </li></ol> | ||
+ | |||
+ | ===Part 13 - Linear Metal Flashing=== | ||
+ | :See the separate page, [[Linear_Metal_Flashing_Details | Details for Linear Metal Flashings]]. | ||
+ | |||
+ | </div> | ||
+ | |||
+ | <div class="col-md-12"> | ||
+ | <hr> | ||
+ | |||
+ | [[Asphalt Shingle Systems Standard|<i class="fa fa-chevron-circle-left" ></i> ''Standard for Asphalt Shingle Roof Systems'']] | ||
+ | |||
+ | [[Main Page | <i class="fa fa-home fa"></i> Home]] | ||
+ | {{Template:RPM Page Footer with Copyright and Current Date}} | ||
+ | </div> |
Latest revision as of 15:53, 30 June 2022
- Division D - Construction Details
- Construction Details for Asphalt Shingle Roof Systems
- The drawings linked on this page are intended to represent a variety of asphalt shingle roof system applications while remaining generic with regards to manufacturer's specific application specifications. They do not represent all possible manufacturer application roof system designs. Consult each manufacturer's specifications and the RoofStar Guarantee Standards to develop a system acceptable to both the manufacturer and the RoofStar Guarantee Program.
- For further information about Asphalt Shingle Roof System designs and requirements, see the Standard for Asphalt Shingle Roof Systems.
Part 6 - Air and Vapour Controls
Continuity and Support ( Article 6.3.2.1.)
Part 9 - Roof Field (Shingle Systems)
Application (Common and Steep Slopes) ( Article 9.3.2.4.)
Application (Low Slopes) ( Article 9.3.2.4.)
Changes in Slope ( Article 9.3.2.7.)
Part 10 - Perimeters and Valleys
Eave and Rake Edge Details ( Article 10.3.4.2.)
Valleys ( Article 10.3.5.2.)
Valley Intersections with Ridge ( Article 10.3.5.9.)
Intersections with Waterproofing Roof Systems ( Article 10.3.7.2.)
Part 11 - Drainage
Membrane Gutters ( Article 11.3.3.8.)
Part 12 - Penetrations and Curbs
Penetration Flashing ( Article 12.3.2.1.)
Curbs ( Article 12.3.2.4.)
Part 13 - Linear Metal Flashing
- See the separate page, Details for Linear Metal Flashings.
Standard for Asphalt Shingle Roof Systems
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.