Difference between revisions of "Manufacturers:Siplast, Inc."
Difference between revisions of "Manufacturers:Siplast, Inc."
(→Roof Deck Insulation) |
(→SBS Membranes) |
||
Line 19: | Line 19: | ||
<big><big>'''Roofs'''</big></big> | <big><big>'''Roofs'''</big></big> | ||
− | ==== [[ | + | ==== [[Insulation]] ==== |
:'''Polyisocyanurate Foam''' | :'''Polyisocyanurate Foam''' | ||
:[[Materials:Paratherm CG|Paratherm CG]] | :[[Materials:Paratherm CG|Paratherm CG]] | ||
Line 25: | Line 25: | ||
:[[Materials:NVS Concrete |NVS Concrete]] | :[[Materials:NVS Concrete |NVS Concrete]] | ||
:[[INSULCEL Concrete|INSULCEL Concrete]] | :[[INSULCEL Concrete|INSULCEL Concrete]] | ||
+ | |||
+ | ==== [[Insulation Overlay Board]] ==== | ||
+ | :'''High Density Overlays (no membrane)''' | ||
+ | :[[Materials:Paratherm HD | {{hilite | Paratherm HD|| 2021-October-30 }}]] | ||
+ | :[[Materials:Paratherm W HD | {{hilite | Paratherm W HD|| 2021-October-30 }}]] | ||
==== [[Bitumen]] ==== | ==== [[Bitumen]] ==== | ||
Line 67: | Line 72: | ||
:[[Materials:Paradiene 30 HT TG |Paradiene 30 HT TG]] | :[[Materials:Paradiene 30 HT TG |Paradiene 30 HT TG]] | ||
:[[Materials:Paradiene 30 TG |Paradiene 30 TG]] (TA) | :[[Materials:Paradiene 30 TG |Paradiene 30 TG]] (TA) | ||
− | :[[Materials:Paradiene 30 TG (Eco-Active) |Paradiene 30 TG (Eco-Active)]] | + | :[[Materials:Paradiene 30 TG (Eco-Active) |Paradiene 30 TG (Eco-Active)]] |
:[[Materials:Paradiene 30 |Paradiene 30]] (TA) | :[[Materials:Paradiene 30 |Paradiene 30]] (TA) | ||
:[[Materials:Paradiene 30 FR TG |Paradiene 30 FR TG]] | :[[Materials:Paradiene 30 FR TG |Paradiene 30 FR TG]] | ||
Line 80: | Line 85: | ||
:[[Materials:Parafor 50 LT |Parafor 50 LT]] | :[[Materials:Parafor 50 LT |Parafor 50 LT]] | ||
:[[Materials:Parafor 50 TG|Parafor 50 TG]] | :[[Materials:Parafor 50 TG|Parafor 50 TG]] | ||
− | + | :[[Materials:Veral AL Polar White Spectra|Veral AL Polar White Spectra]] | |
− | |||
− | |||
− | :[[Materials:Veral AL Polar White Spectra|Veral AL Polar White Spectra]] | ||
:[[Materials:Veral AL |Veral AL (Aluminum)]] | :[[Materials:Veral AL |Veral AL (Aluminum)]] | ||
− | + | :[[Materials:Veral SS|Veral SS]] | |
− | :[[Materials:Veral SS|Veral SS]] | ||
:[[Materials:Teranap (1m x 8m) |Teranap (1m x 8m)]] | :[[Materials:Teranap (1m x 8m) |Teranap (1m x 8m)]] | ||
:[[Materials:Teranap 431 (2m x 20m) |Teranap 431 (2m x 20m)]] | :[[Materials:Teranap 431 (2m x 20m) |Teranap 431 (2m x 20m)]] | ||
− | + | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
:'''Single-ply Membranes''' | :'''Single-ply Membranes''' | ||
:[[Materials:Parafor 50 LT|Parafor 50 LT]] | :[[Materials:Parafor 50 LT|Parafor 50 LT]] | ||
:[[Materials:Parafor 50 TG|Parafor 50 TG]] | :[[Materials:Parafor 50 TG|Parafor 50 TG]] | ||
− | |||
====[[Flexible Membrane Roofing Systems: Liquid Membrane Systems|Liquid Membrane Systems (Field Application)]]==== | ====[[Flexible Membrane Roofing Systems: Liquid Membrane Systems|Liquid Membrane Systems (Field Application)]]==== | ||
Line 138: | Line 132: | ||
'''Two-part Reinforced Liquid Membrane Flashing''' | '''Two-part Reinforced Liquid Membrane Flashing''' | ||
:[[Materials:Parapro 123 Flashing Resin |Parapro 123 Flashing Resin]] | :[[Materials:Parapro 123 Flashing Resin |Parapro 123 Flashing Resin]] | ||
+ | </div> | ||
+ | |||
+ | <div class="col-md-3"> | ||
+ | <hr> | ||
+ | <big><big><u>Water-shedding System Materials</u></big></big> | ||
+ | |||
+ | ==== [[Eave Protection & Underlayment (Asphalt Shingles, Cedar Shakes & Shingles)|Eave Protection & Underlayment (Shakes & Shingles)]] ==== | ||
+ | :[[Materials:Paradiene 20 EG SA|{{hilite | Paradiene 20 EG SA|| 2021-October-30 }}]] | ||
+ | |||
+ | ====[[Eave Protection & Underlayment (Architectural Metal Roofing)|Eave Protection & Underlayment (ASM)]]==== | ||
+ | :[[Materials:Paradiene 20 EG SA|{{hilite | Paradiene 20 EG SA|| 2021-October-30 }}]] | ||
− | < | + | ====[[Insulation Overlays (Water-shedding Systems)|Insulation Overlays]]==== |
+ | :'''High Density Overlays (no membrane)''' | ||
+ | :[[Materials:Paratherm HD | {{hilite | Paratherm HD|| 2021-October-30 }}]] | ||
+ | :[[Materials:Paratherm W HD | {{hilite | Paratherm W HD|| 2021-October-30 }}]] | ||
+ | </div> | ||
+ | <div class="col-md-12"> | ||
+ | <hr> | ||
+ | ====[[Accessories]]==== | ||
+ | |||
+ | {| class="wikitable" | style="color: black; background-color: orange; border: orange; width: 100%;" | ||
+ | | colspan="2" | An ''Accessory'' is a material that joins ''Primary'' or ''Secondary Materials'' together, or is connected to/with a ''Primary'' or ''Secondary material'', but does not by its nature (apart from its installation) directly affect the water or wind resistance of the ''Waterproofing'' or ''Water-shedding system''. An '''Accessory''' is not an Accepted Material and therefore the '''''RoofStar Guarantee''''' does not extend to cover any potential material or installation failure. Accessories are listed in the '''''Roofing Practices Manual''''' merely for reference to specifiers, designers and installers. | ||
+ | |} | ||
+ | </div> | ||
+ | <div class="col-md-4"> | ||
+ | :'''Coatings''' | ||
:[[Materials: Paracoat Roof Coating|Paracoat Roof Coating]] | :[[Materials: Paracoat Roof Coating|Paracoat Roof Coating]] | ||
</div> | </div> | ||
Line 149: | Line 168: | ||
[[Materials by Manufacturer/Distributor/Certifying Authority|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Materials by Manufacturer/Distributor/Certifying Authority'']] | [[Materials by Manufacturer/Distributor/Certifying Authority|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Materials by Manufacturer/Distributor/Certifying Authority'']] | ||
− | [[Materials | + | [[Division C: Accepted Materials|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Accepted Materials'']] |
[[Main Page|Home]] | [[Main Page|Home]] | ||
</div> | </div> |
Revision as of 19:10, 12 November 2020
The roofing assembly / materials listed below are accepted for use in the RoofStar Guarantee Program. Technical Data Sheets (TDS) may be found by clicking on the product link, unless indicated otherwise. |
Manufacturer: Siplast
|
- Click the heading for a material type to link to tables displaying all other Accepted Materials in the same category
- Materials shown with "TA" after the name have been used in wind-resistant Tested Assemblies. See also Securing the Roof Assembly and links to MARS, PARS and AARS material tables.
Waterproofing System Materials
Roofs
Insulation
- Polyisocyanurate Foam
- Paratherm CG
- Lightweight Concrete
- NVS Concrete
- INSULCEL Concrete
Insulation Overlay Board
- High Density Overlays (no membrane)
- Paratherm HD
- Paratherm W HD
Bitumen
SBS Membranes
Roofs cont.
- Base Membranes (for use only with ParaPro PMMA Roof Membrane Resin)
- Paradiene 20 EG TG P
- Paradiene 20 P
- Paradiene 20 SA P
- Paradiene 20 TG P
- Paradiene 20 TS P
- Paradiene 20 TS SA P
- Cap Membranes
- Paradiene 30 FR
- Paradiene 30 HT TG
- Paradiene 30 TG (TA)
- Paradiene 30 TG (Eco-Active)
- Paradiene 30 (TA)
- Paradiene 30 FR TG
- Paradiene 30 HT FR
- Paradiene 30 HT FR TG
- Paradiene 30 HT
- Paradiene 40 (awaiting TDS)
- Paradiene 40 FR
- Paradiene 40 FR TG
- Parafor 30 TG
- Parafor 30 TG (Eco-Active) (awaiting TDS)
- Parafor 50 LT
- Parafor 50 TG
- Veral AL Polar White Spectra
- Veral AL (Aluminum)
- Veral SS
- Teranap (1m x 8m)
- Teranap 431 (2m x 20m)
- Single-ply Membranes
- Parafor 50 LT
- Parafor 50 TG
Liquid Membrane Systems (Field Application)
For a complete list of Technical Data Sheets, click on the system link below. Note that this field-applied liquid membrane may be used only on:
- epoxy primer-treated concrete (Protected Membrane Roof Assemblies and Plaza Waterproofing) or
- with Paradiene "P" membranes (listed on this page).
Liquid Membrane Flashing
Two-part Reinforced Liquid Membrane Flashing
Grade-level Waterproofing
Waterproofing Membrane Systems
- SBS 2-Ply Membrane Systems
- SBS Waterproofing Installation Guidelines
- Base Membranes
- Teranap 431 (2m x 20m)
- Teranap (1m x 8m)
- Cap Membranes
- Teranap 431 (2m x 20m)
- Teranap (1m x 8m)
Liquid Membrane Systems (Field Application)
For a complete list of Technical Data Sheets, click on the system link below. Note that this field-applied liquid membrane may be used only on:
- epoxy primer-treated concrete (Protected Membrane Roof Assemblies and Plaza Waterproofing) or
- with Paradiene "P" membranes (listed on this page).
Liquid Membrane Flashing
Two-part Reinforced Liquid Membrane Flashing
Water-shedding System Materials
Eave Protection & Underlayment (Shakes & Shingles)
Eave Protection & Underlayment (ASM)
Insulation Overlays
- High Density Overlays (no membrane)
- Paratherm HD
- Paratherm W HD
Accessories
An Accessory is a material that joins Primary or Secondary Materials together, or is connected to/with a Primary or Secondary material, but does not by its nature (apart from its installation) directly affect the water or wind resistance of the Waterproofing or Water-shedding system. An Accessory is not an Accepted Material and therefore the RoofStar Guarantee does not extend to cover any potential material or installation failure. Accessories are listed in the Roofing Practices Manual merely for reference to specifiers, designers and installers. |
- Coatings
- Paracoat Roof Coating