Line 19: | Line 19: | ||
;'''Panel Machine''': New Tech Machinery SSQ2U | ;'''Panel Machine''': New Tech Machinery SSQ2U | ||
;'''Panel Name''': SSQ II | ;'''Panel Name''': SSQ II | ||
− | ;'''Seam Type''': Mechanical / Snap-Lock | + | ;'''Seam Type''': Mechanical / Snap-Lock with 'Nailing Strip' |
The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. | The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. | ||
Line 31: | Line 31: | ||
====SYSTEM DESCRIPTION==== | ====SYSTEM DESCRIPTION==== | ||
#'''General''': The New Tech SSQ II standing seam panel is secured with concealed fastener. The maximum spacing of screws in the built in 'nailing strip' is 635mm (24") | #'''General''': The New Tech SSQ II standing seam panel is secured with concealed fastener. The maximum spacing of screws in the built in 'nailing strip' is 635mm (24") | ||
− | #'''Range of application''': Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction. | + | #'''Range of application''': Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction. Note that panels with a 'nailing strip' are restricted in their length (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#9.2.1.1._Panel_Grade.2C_Gauge.2C_and_Selection Article 9.2.1.1., Sentence (6)]. |
#'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications. | #'''Panel Attachment''': Fastening is site specific, engineer must confirm fixing specifications. | ||
#'''Fasteners (Screws)''': | #'''Fasteners (Screws)''': | ||
Line 38: | Line 38: | ||
#'''Panel Clips''': One piece assembly manufactured by New Tech Machinery (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.3._Resistance_to_Specified_Wind_Loads Article 3.1.3.3.] and [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.5._Submittals Article 3.1.3.5.]). | #'''Panel Clips''': One piece assembly manufactured by New Tech Machinery (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.3._Resistance_to_Specified_Wind_Loads Article 3.1.3.3.] and [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.5._Submittals Article 3.1.3.5.]). | ||
#'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | #'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | ||
+ | <br> | ||
− | ==== | + | ====PROFILES==== |
− | + | <div class="col-md-12"> | |
+ | <div class="col-md-4"> | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! SSQII Mechanical Lock 38.1 mm (1-1/2") Panel | ||
+ | |- | ||
+ | | [[File:G&G New Tech SSQII Mechanical Lock 1.5-inch Profile.png|frameless|link=https://rpm.rcabc.org/images/d/d0/G%26G_New_Tech_SSQII_Mechanical_Lock_1.5-inch_Profile.png|450px]] | ||
+ | |} | ||
+ | </div> | ||
+ | |||
+ | <div class="col-md-4"> | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! SSQII Mechanical Lock 50.8 mm (2") Panel | ||
+ | |- | ||
+ | | [[File:G&G New Tech SSQII Mechanical Lock 2-inch Profile.png|frameless|link=https://rpm.rcabc.org/images/1/1e/G%26G_New_Tech_SSQII_Mechanical_Lock_2-inch_Profile.png|450px]] | ||
+ | |} | ||
+ | </div> | ||
+ | |||
+ | <div class="col-md-4"> | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | ! SSQII Snap Lock "Nailing Strip" 25.4 mm (1") Panel | ||
+ | |- | ||
+ | | [[File:G&G New Tech SSQII Nailing Strip 1-inch Profile.png|frameless|link=https://rpm.rcabc.org/images/9/97/G%26G_New_Tech_SSQII_Nailing_Strip_1-inch_Profile.png|450px]] | ||
+ | |} | ||
+ | </div> | ||
+ | </div> | ||
+ | </div> | ||
+ | <div class="col-md-12"> | ||
+ | </div> | ||
====TECHNICAL DATA SHEET==== | ====TECHNICAL DATA SHEET==== | ||
− | + | Click below for the '''Technical Data Sheet''' | |
+ | |||
+ | <div style="width:150px; text-align: left;"> | ||
+ | [[File:Pdf.png|75 px|link=https://rpm.rcabc.org/images/0/03/G%26G_New_Tech_TDS.pdf|'''Technical Data Sheet''']] | ||
+ | </div> | ||
====SITE CONDITIONS==== | ====SITE CONDITIONS==== | ||
Line 53: | Line 88: | ||
<li>'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#Section_9.2._Materials Section 9.2.] of the Standard. | <li>'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#Section_9.2._Materials Section 9.2.] of the Standard. | ||
</li></ol> | </li></ol> | ||
+ | |||
<hr> | <hr> |
Latest revision as of 15:45, 30 November 2023
Division C - Accepted Materials
New Tech Machinery SSQ II
by G&G Roofing Ltd.
The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program. |
The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. |
OVERVIEW
The New Tech SSQ II standing seam panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine (New Tech Machinery SSQ2U). This machine produces a standing seam panel with a seam height of 38 mm (1-1/2") or 50.8 mm (2") and profiles can vary from 304.8 mm (12") wide up to 508 mm (20") wide.
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to 300'.
SYSTEM DESCRIPTION
- General: The New Tech SSQ II standing seam panel is secured with concealed fastener. The maximum spacing of screws in the built in 'nailing strip' is 635mm (24")
- Range of application: Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction. Note that panels with a 'nailing strip' are restricted in their length (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, Article 9.2.1.1., Sentence (6).
- Panel Attachment: Fastening is site specific, engineer must confirm fixing specifications.
- Fasteners (Screws):
- Fasteners used to attach panel clips to steel must be specified by the registered engineering professional but are usually No. 10-16 by 25 mm (1") long self-drilling, self-tapping pancake head plates steel screws. Use two fasteners per panel clip, inserted into panel clip guide holes, or as otherwise specified by the registered engineering professional.
- Fasteners used to attach panel clips to plywood must be specified by the registered engineering professional but are usually No. 10-16 by 25 mm (1") long pancake head plated steel screws for wood. Use two fasteners per clip, inserted into panel guide holes, or as otherwise specified by the registered engineering professional.
- Panel Clips: One piece assembly manufactured by New Tech Machinery (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, Article 3.1.3.3. and Article 3.1.3.5.).
- Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.
PROFILES
TECHNICAL DATA SHEET
Click below for the Technical Data Sheet
SITE CONDITIONS
Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
PERFORMANCE REQUIREMENTS
- Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
- Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.