Difference between revisions of "Materials:(Lam) SS 150 Standing Seam (38 mm)"

Jump to: navigation, search

Difference between revisions of "Materials:(Lam) SS 150 Standing Seam (38 mm)"

(Created page with "__NOTOC__ __NONUMBEREDHEADINGS__ {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} <big>...")
 
(PERFORMANCE REQUIREMENTS)
 
(One intermediate revision by the same user not shown)
Line 5: Line 5:
 
<big><big>Division C - Accepted Materials</big></big>
 
<big><big>Division C - Accepted Materials</big></big>
 
<hr>
 
<hr>
<big><big><big><big><big>Nu-Tech SS 150</big></big></big></big></big><br>
+
<big><big><big><big><big>SS 150 Standing Seam</big></big></big></big></big><br>
 
<big><big><big>by Lam Metal Contracting Ltd.</big></big></big><br>
 
<big><big><big>by Lam Metal Contracting Ltd.</big></big></big><br>
 
{| class="wikitable"
 
{| class="wikitable"
Line 86: Line 86:
 
====PERFORMANCE REQUIREMENTS====
 
====PERFORMANCE REQUIREMENTS====
 
<ol>
 
<ol>
<li>'''Wind Uplift Standards''': Engineered designs to resist wind uplift may refer to the British Columbia Building Code, Div. B, Appendix C, Table C-2 which lists various types of loads, including wind loads, for specific reference locations throughout the province. See also [http://{{SERVERNAME}}/index.php?title=ASM_Application_Guides_and_Notes Guides and Notes (Wind Resistance)] for a simplified calculation procedure. Regardless of the resources indicated here, the ''Design Authority'' is responsible to perform accurate wind load calculations and specify securement requirements.
+
<li>'''Wind Uplift Resistance''': Panel securement shall conform to the requirements in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#PART_3 Part 3] of the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].
<li>'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the standards published in the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].
+
<li>'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#Section_9.2._Materials Section 9.2.] of the Standard.
 
</li></ol>
 
</li></ol>
  

Latest revision as of 17:15, 26 October 2023



Division C - Accepted Materials


SS 150 Standing Seam
by Lam Metal Contracting Ltd.

Material Acceptance and Product Details


The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this material recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Manufacturer
Lam Metal Contracting Ltd.
Contact Address
See the current Membership list and contact information at www.rcabc.org
Product Group - Standing Seam Metal Roof System
Panel Machine
Nu-Tech
Panel Name
SS 150
Seam Type
Mechanical Lock

The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer.

OVERVIEW

The SS 150 standing seam panel is formed in-house with an Nu-Tech SSP continuous metal roofing panel roll forming machine. This machine produces a standing seam panel with a seam height of 38.1 mm (1-1/2"). Profiles can vary from 304.8 mm (12") wide to 609.6 mm (24") wide.

This machine also produces the Nu-Tech SS200 panel profile and a 44 mm (1-3/4") high Nu-Tech panel profile.

SYSTEM DESCRIPTION

  1. General: The SS 150 panel is a standing seam concealed fastener roofing panel. The maximum spacing of the clips is 609.6 mm (24") O.C.
  2. Range of application: on wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
  3. Fasteners (Screws):
    1. Fasteners (screws) used to attach panels to plywood deck to be No. 10-12 by 19.05 mm (5/8") long pancake head wood screw. Minimum two fasteners per clip to be used.
    2. Two-piece assembly consists of a steel base approximately 127 mm (5") wide x 25.4 mm (1") long, with a minimum thickness of 0.026 (No. 24 MSG) and an upper tab that measures 50.8 mm high with a minimum thickness of 0.020 (No. 26 MSG). One panel clip spaced at 609.6 mm (24") O.C. maximum.
  4. Fabrication: Unless otherwise shown on drawings or specified herein, fabricate panels in continuous one piece lengths and fabricate flashings and accessories in longest practical lengths.
  5. Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.

PROFILE

SS 150 Standing Seam Panel
Lam Metals SS 150 profile.png

DELIVERY, STORAGE & HANDLING

  1. Protect against damage and discoloration.
  2. Handle panels with non-marring slings.
  3. Do not bend panels.
  4. Store panels above ground, with one end elevated for drainage.
  5. Protect panels against standing water and condensation between adjacent surfaces.
  6. If panels become wet, immediately separate sheets, wipe dry with clean cloth, allow to air dry.

FIELD MEASUREMENTS

  1. Verify prior to fabrication.
  2. If field measurements differ from drawing dimensions, notify Architect / Professional Engineer prior to fabrication.

PROTECTION

Treat, or isolate with protective material, any contacting surfaces of dissimilar materials to prevent electrolytic corrosion.

PROFILE

N/A

TECHNICAL DATA SHEET

N/A

SITE CONDITIONS

  1. Minimum roof slope is 1:6 (2" in 12").
  2. Verify that structural deck to receive panels is complete, in true plane, secure and otherwise properly prepared.
  3. Prior to starting work, notify General Contractor about defects requiring correction.
  4. Do not start work until conditions are satisfactory.

PERFORMANCE REQUIREMENTS

  1. Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
  2. Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.


Back to Site-Formed Metal Roofing Systems

Back to Accepted Materials


Home