Difference between revisions of "SBS Roof System Details"
Difference between revisions of "SBS Roof System Details"
Line 1: | Line 1: | ||
{{Template:RPM Info}} | {{Template:RPM Info}} | ||
− | |||
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
__NOTOC__ | __NOTOC__ | ||
Line 23: | Line 22: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
<hr> | <hr> | ||
− | ==== | + | ====GENERAL==== |
− | : | + | :[[SBS 1.3.1-1 Conventionally Insulated System (typical) | {{hilite | SBS 1.3.1-1 Conventionally Insulated System (typical)|| 2021-February-7 }}]] |
− | + | :[[SBS 1.3.1-2 Conventionally Insulated System (alternate) | {{hilite | SBS 1.3.1-2 Conventionally Insulated System (alternate)|| 2021-February-7 }}]] | |
− | :[[SBS | + | :[[SBS 1.3.1-3 Protected Membrane Roof Assembly (typical) | {{hilite | SBS 1.3.1-3 Protected Membrane Roof Assembly (typical)|| 2021-February-7 }}]] |
− | :[[SBS | ||
− | ==== | + | ====SUPPORTING STRUCTURES: Decks and Walls==== |
− | + | ====SECURING the ROOF ASSEMBLY==== | |
− | |||
− | ==== | + | ====MATERIALS==== |
− | + | ====DECK and WALL OVERLAYS==== | |
− | |||
− | |||
− | |||
− | + | ====AIR and VAPOUR CONTROLS==== | |
− | :[[SBS | + | :[[SBS 6.3.1 Air and Vapour Controls (field) | {{hilite | SBS 6.3.1 Air and Vapour Controls (field)|| 2021-February-7 }}]] |
− | |||
− | |||
− | |||
− | + | ====INSULATION==== | |
− | |||
− | |||
− | + | ====INSULATION OVERLAYS==== | |
− | |||
− | |||
− | + | ====FIELD MEMBRANE==== | |
− | |||
− | |||
− | : | + | ====PERIMETERS and WALLS==== |
− | :[[SBS 10.3.1- | + | :[[SBS 10.3.1-1 Perimeter Membrane Termination (typical) | SBS 10.3.1-1 Perimeter Membrane Termination (typical)]] |
− | :[[SBS 10.3. | + | :[[SBS 10.3.1-2 Perimeter Membrane Termination (expansion joint) | SBS 10.3.1-2 Perimeter Membrane Termination (expansion joint)]] |
+ | :[[SBS 10.3.1-3 Perimeter Membrane Termination (stucco wall, replacement roofing) | SBS 10.3.1-3 Perimeter Membrane Termination (stucco wall, replacement roofing)]] | ||
+ | :[[SBS 10.3.1-4 Perimeter Membrane Termination (double surface reglet)| SBS 10.3.1-4 Perimeter Membrane Termination (double surface reglet)]] | ||
− | : | + | :[[SBS 10.3.5.1-1 Parapet (typical)| SBS 10.3.5.1-1 Parapet (typical)]] |
− | :[[SBS 10.3.6.2 Control Joint (Roof Divider)| Control Joint ( | + | :[[SBS 10.3.5.1-2 Parapet (independent of roof structure)(typical) | SBS 10.3.5.1-2 Parapet (independent of roof structure)(typical)]] |
+ | :[[SBS 10.3.5.1-3 Parapet, tall (typical) | SBS 10.3.5.1-3 Parapet, tall (typical)]] | ||
+ | :[[SBS 10.3.5.1-4 Parapet (wall tie-in) | SBS 10.3.5.1-4 Parapet (wall tie-in)]] | ||
+ | |||
+ | :[[SBS 10.3.5.2 Metal Edge Termination | {{hilite | SBS 10.3.5.2 Metal Edge Termination|| 2021-February-7 }}]] | ||
+ | :[[SBS 10.3.5.3 Canted Edge | {{hilite | SBS 10.3.5.3 Canted Edge|| 2021-February-7 }}]] | ||
+ | |||
+ | :[[SBS 10.3.6.1 Expansion Joint| SBS 10.3.6.1 Expansion Joint]] | ||
+ | :[[SBS 10.3.6.2 Control Joint (Roof Divider)| SBS 10.3.6.2 Control Joint (Roof Divider)]] | ||
+ | |||
+ | :[[SBS 10.3.7.1 Low Door Opening | {{hilite | SBS 10.3.7.1 Low Door Opening || 2022-February-5 }}]] | ||
+ | :[[SBS 10.3.7.2 Window Curb | SBS 10.3.7.2 Window Curb]] | ||
+ | |||
+ | :[[SBS 10.3.9-1 Roof-Wall Transitions (fire separation joint)| SBS 10.3.9-1 Roof-Wall Transitions (fire separation joint)]] | ||
+ | :[[SBS 10.3.9-2 Roof-Wall Transitions (fire separation wall)| SBS 10.3.9-2 Roof-Wall Transitions (fire separation wall)]] | ||
</div> | </div> | ||
Line 70: | Line 71: | ||
<hr> | <hr> | ||
− | ==== | + | ====11 DRAINS and PENETRATIONS==== |
− | : | + | :[[SBS 11.3.2.2-1 Cast Iron Drains| SBS 11.3.2.2-1 Cast Iron Drains]] |
− | |||
− | : | + | :[[SBS 11.3.2.4-1 Flange-style Drains (typical)| SBS 11.3.2.4-1 Flange-style Drains (typical)]] |
− | + | :[[SBS 11.3.2.4-2 Flange-style Drains (clamping)| SBS 11.3.2.4-2 Flange-style Drains (clamping)]] | |
− | :[[SBS 11.3.2.4-2 Flange-style Drains (clamping)| | ||
− | : | + | :[[SBS 11.3.2.5-1 Scuppers and Overflows (open wall scupper)| SBS 11.3.2.5-1 Scuppers and Overflows (open wall scupper)]] |
− | :[[SBS 11.3.2.5- | + | :[[SBS 11.3.2.5-2 Scuppers and Overflows (through-wall scupper)| SBS 11.3.2.5-2 Scuppers and Overflows (through-wall scupper)]] |
− | |||
− | + | :[[SBS 11.3.3.2-1 Curbs and Sleepers (basic curb)| {{hilite | SBS 11.3.3.2-1 Curbs and Sleepers (basic curb)|| 2021-February-7 }}]] | |
+ | :[[SBS 11.3.3.2-2 Curbs and Sleepers (equipment sleeper)| SBS 11.3.3.2-2 Curbs and Sleepers (equipment sleeper)]] | ||
+ | :[[SBS 11.3.3.2-3 Curbs and Sleepers (mechanical opening)| SBS 11.3.3.2-3 Curbs and Sleepers (mechanical opening)]] | ||
+ | :[[SBS 11.3.3.2-4 Curbs and Sleepers (multiple penetrations)| SBS 11.3.3.2-4 Curbs and Sleepers (multiple penetrations)]] | ||
− | : | + | :[[SBS 11.3.3.3-1 Penetration Flashings (plumbing vent)| SBS 11.3.3.3-1 Penetration Flashings (plumbing vent)]] |
− | + | :[[SBS 11.3.3.3-2 Penetration Flashings (two-part cable)| {{hilite | SBS 11.3.3.3-2 Penetration Flashings (two-part cable)|| 2021-February-7 }}]] | |
− | :[[SBS 11.3.3.3-2 Penetration Flashings (two-part cable)| {{hilite | | ||
− | |||
− | |||
− | |||
− | |||
− | + | :[[SBS 11.3.3.4 Sealant Pocket| SBS 11.3.3.4 Sealant Pocket]] | |
− | :[[SBS 11.3.3. | ||
− | |||
− | |||
− | : | + | :[[SBS 11.3.4 Guardrails | SBS 11.3.4 Guardrails]] |
− | |||
− | : | + | :[[SBS 11.3.5-1 Roof Anchors (typical) | SBS 11.3.5-1 Roof Anchors (typical)]] |
− | :[[SBS 11.3.3. | + | :[[SBS 11.3.5-2 Roof Anchors (conventional system) | SBS 11.3.5-2 Roof Anchors (conventional system)]] |
+ | :[[SBS 11.3.5-3 Roof Anchors (PMRA) | SBS 11.3.5-3 Roof Anchors (PMRA)]] | ||
− | ==== | + | ====PROTECTED MEMBRANES and OTHER DETAILS==== |
− | |||
− | ==== | + | ====METAL FLASHINGS==== |
− | + | ====THE ROOF as a PLATFORM==== | |
− | :[[SBS 14.3.3 Structures and Equipment (planter pre-curb) | | + | :[[SBS 14.3.3 Structures and Equipment (planter pre-curb) | SBS 14.3.3 Structures and Equipment (planter pre-curb)]] |
</div> | </div> |
Revision as of 20:46, 10 June 2022
- Division D - Construction Details
- Construction Details for SBS-modified Bitumen Membrane Roof Systems
- The drawings linked on this page are intended to represent a variety of SBS-modified Bitumen Membrane roof system applications while remaining generic with regards to manufacturers’ specific application specifications. They do not represent all possible manufacturer application roof system designs. Consult each manufacturers’ specifications and the RoofStar Guarantee Standards to develop a system acceptable to both the manufacturer and the RoofStar Guarantee Program.
- For further information about SBS-modified Bitumen Membrane System designs and requirements, see the Standard for SBS-modified Bitumen Membrane Roof Systems.
NOTE: 'PDF' shown after a file name below indicates a downloadable print sheet is available for Construction Details. Click on the detail link and look for the icon.
1 GENERAL
- SBS 1.3.1-1 Conventionally Insulated System (typical)
- SBS 1.3.1-2 Conventionally Insulated System (alternate)
- SBS 1.3.1-3 Protected Membrane Roof Assembly (typical)
2 SUPPORTING STRUCTURES: Decks and Walls
3 SECURING the ROOF ASSEMBLY
4 MATERIALS
5 DECK and WALL OVERLAYS
6 AIR and VAPOUR CONTROLS
7 INSULATION
8 INSULATION OVERLAYS
9 FIELD MEMBRANE
10 PERIMETERS and WALLS
- SBS 10.3.1-1 Perimeter Membrane Termination (typical)
- SBS 10.3.1-2 Perimeter Membrane Termination (expansion joint)
- SBS 10.3.1-3 Perimeter Membrane Termination (stucco wall, replacement roofing)
- SBS 10.3.1-4 Perimeter Membrane Termination (double surface reglet)
11 11 DRAINS and PENETRATIONS
- SBS 11.3.2.5-1 Scuppers and Overflows (open wall scupper)
- SBS 11.3.2.5-2 Scuppers and Overflows (through-wall scupper)
- SBS 11.3.3.2-1 Curbs and Sleepers (basic curb)
- SBS 11.3.3.2-2 Curbs and Sleepers (equipment sleeper)
- SBS 11.3.3.2-3 Curbs and Sleepers (mechanical opening)
- SBS 11.3.3.2-4 Curbs and Sleepers (multiple penetrations)
- SBS 11.3.3.3-1 Penetration Flashings (plumbing vent)
- SBS 11.3.3.3-2 Penetration Flashings (two-part cable)
- SBS 11.3.5-1 Roof Anchors (typical)
- SBS 11.3.5-2 Roof Anchors (conventional system)
- SBS 11.3.5-3 Roof Anchors (PMRA)
12 PROTECTED MEMBRANES and OTHER DETAILS
13 METAL FLASHINGS
14 THE ROOF as a PLATFORM
Standard for SBS-modified Bitumen Membrane Roof Systems
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.