Line 40: | Line 40: | ||
<li>Fasteners used for drag load securement must be (minimum) No. 12 x 38.1 mm (1-1/2") hex head cladding screws. | <li>Fasteners used for drag load securement must be (minimum) No. 12 x 38.1 mm (1-1/2") hex head cladding screws. | ||
</li></ol> | </li></ol> | ||
− | <li>'''Panel Clips''': One piece assembly 76.2 mm (3") long, 25.4 mm (1") wide, and 47.6 mm (1-7/8") high, manufactured by New Tech Machinery (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C., or as | + | <li>'''Panel Clips''': One piece assembly 76.2 mm (3") long, 25.4 mm (1") wide, and 47.6 mm (1-7/8") high, manufactured by New Tech Machinery (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.3._Resistance_to_Specified_Wind_Loads Article 3.1.3.3.] and [http://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#3.1.3.5._Submittals Article 3.1.3.5.]) |
<li>'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | <li>'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems]. | ||
</li></ol> | </li></ol> |
Revision as of 14:19, 27 October 2023
Division C - Accepted Materials
New Tech SSQ675
by Langley Roofing Co. Ltd.
The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program. |
The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer. |
OVERVIEW
The New Tech SSQ675 snap-lock metal panel is formed with an on-site/in shop continuous metal roofing panel roll forming machine (New Tech Machinery SSQ II). This machine produces a standing seam panel with a seam height of 45.2 mm (1-3/4") and profiles can vary from 305mm (12") wide up to 609.6 mm (24") wide.
On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities in lengths up to 150'.
SYSTEM DESCRIPTION
- General: The New Tech SSQ675 snap-lock metal panel is secured with concealed fastener.
- Range of application: Installed on wood or steel sloped roofs, in commercial, institutional, industrial and residential construction. For re-roofing or new construction.
- Panel Attachment: Fastening is site specific, engineer must confirm fixing specifications.
- Fasteners (Screws):
- Fasteners used to attach panel clips to steel must be (minimum) No. 10 by 38.1 mm (1-1/2") long self-drilling, self-tapping pancake head plates steel screws. Use two fasteners per panel clip, inserted into panel clip guide holes.
- Fasteners used to attach panel clips to plywood must be (minimum) No. 10 by 38.1 mm (1-1/2") long pancake head plated steel screws for wood. Use two fasteners per clip, inserted into panel guide holes.
- Fasteners used for drag load securement must be (minimum) No. 12 x 38.1 mm (1-1/2") hex head cladding screws.
- Panel Clips: One piece assembly 76.2 mm (3") long, 25.4 mm (1") wide, and 47.6 mm (1-7/8") high, manufactured by New Tech Machinery (or approved equal). Minimum thickness 0.022 in. (No. 22 MSG). Clips spaced maximum 600 mm (24") O.C., or as specified on engineered shop drawings (Ref. Standard for Architectural Sheet Metal (ASM) Roof Systems, Article 3.1.3.3. and Article 3.1.3.5.)
- Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.
PROFILE
BA-Versasnap (FF 100) Standing Seam Panel |
---|
TECHNICAL DATA SHEET
Click below for the Technical Data Sheet
SITE CONDITIONS
Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
PERFORMANCE REQUIREMENTS
- Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
- Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.