Line 4: | Line 4: | ||
|+ How to use the table: | |+ How to use the table: | ||
− | # | + | #In the table below look for maximum <u>wind uplift values that exceed</u> the requirements determined through the RCI calculator;<p>('''NOTE''': while the reports show two different values for tested maximum assembly strength, the RPM tables display only the values adjusted for the required safety factor of 1.5)</p> |
#Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report. It will break down the assembly by its components. Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the '''''RoofStar Guarantee Program''''' (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer); | #Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report. It will break down the assembly by its components. Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the '''''RoofStar Guarantee Program''''' (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer); | ||
− | #In cases where a tested Secondary material is not accepted by the '''''RoofStar Guarantee Program''''', look for alternates which often are published in the each report. In the absence of published alternates, locate a possible alternate in the [http://rpm.rcabc.org/index.php?title=Materials_by_Product_Type '''Accepted Materials'''] section of this Manual. If you are unsure about compatibility, contact the [mailto:guarantees@rcabc.org '''RCABC''']. | + | #In cases where a tested Secondary material is not accepted by the '''''RoofStar Guarantee Program''''', look for alternates which often are published in the each report. In the absence of published alternates, locate a possible alternate in the [http://rpm.rcabc.org/index.php?title=Materials_by_Product_Type '''Accepted Materials'''] section of this Manual. If you are unsure about compatibility, contact the [mailto:guarantees@rcabc.org '''RCABC''']. |
! style="vertical-align:top;" | Manufacturer | ! style="vertical-align:top;" | Manufacturer | ||
! style="vertical-align:top;" | Product Name | ! style="vertical-align:top;" | Product Name |
Revision as of 19:05, 18 July 2017
Manufacturer | Product Name | Number of Tested Systems (per report) |
kPa (Low) | kPa (High) | Psf (Low) | Psf (High) | Deck Type | Downloadable Test Report | Test Facility | Test Facility Report No. |
---|---|---|---|---|---|---|---|---|---|---|
IKO Industries Ltd. | Armourcool Granular TP-HD Cap | 2 Tested Systems 3 Tested Systems |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
Steel Steel |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 |
IKO Industries Ltd. | Torchflex TP-180 Cap | 2 Tested Systems 3 Tested Systems |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
Steel Steel |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 |
IKO Industries Ltd. | Torchflex TP-250 Cap 5 mm | 2 Tested Systems 3 Tested Systems |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
Steel Steel |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 |
IKO Industries Ltd. | Torchflex TP-250 Cap | 2 Tested Systems 3 Tested Systems |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
Steel Steel |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 |
IKO Industries Ltd. | Torchflex TP-HD-Cap | 2 Tested Systems 3 Tested Systems |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
Steel Steel |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 |
IKO Industries Ltd. | Prevent TP 250 Cap 4 mm | 2 Tested Systems 3 Tested Systems |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
Steel Steel |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 |
IKO Industries Ltd. | Prevent TP-HD-Cap | 2 Tested Systems 3 Tested Systems |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
Steel Steel |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 |
IKO Industries Ltd. | Prevent Premium TP 250 Cap 4 mm | 2 Tested Systems 3 Tested Systems |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
Steel Steel |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 |
Soprema Inc. | Soprafix Traffic Cap 660 | 3 Tested Systems 3 Tested Systems 4 Tested Systems 1 Tested System 3 Tested Systems 3 Tested Systems 3 Tested Systems 2 Tested Systems |
-1.80 -2.40 -2.00 ---- -1.60 -2.40 -1.90 -1.80 |
-3.40 -5.20 -6.20 -2.40 -3.20 -5.20 -4.80 -2.40 |
-37.00 -50.00 -42.00 ---- -33.00 -50.00 -40.00 -37.0 |
-70.00 -108.00 -130.00 -50.00 -67.00 -108.00 -100.00 -50.00 |
Steel Steel Steel Plywood Plywood Steel Steel Steel |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRU168540 PUB-DRU168534 PUB-DRU206751 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 |
Soprema Inc. | Soprafix Traffic Cap FR 661 | 3 Tested Systems 3 Tested Systems 4 Tested Systems 1 Tested System 3 Tested Systems 3 Tested Systems 3 Tested Systems 2 Tested Systems |
-1.80 -2.40 -2.00 ---- -1.60 -2.40 -1.90 -1.80 |
-3.40 -5.20 -6.20 -2.40 -3.20 -5.20 -4.80 -2.40 |
-37.00 -50.00 -42.00 ---- -33.00 -50.00 -40.00 -37.0 |
-70.00 -108.00 -130.00 -50.00 -67.00 -108.00 -100.00 -50.00 |
Steel Steel Steel Plywood Plywood Steel Steel Steel |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRU168540 PUB-DRU168534 PUB-DRU206751 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 |
Soprema Inc. | Soprafix Unilay 750 | 4 Tested Systems | -2 | -5.2 | -41 | -108 | Steel | MARS Test Report 7 | exp. Service Inc. | PUB-DRU168549 |
Soprema Inc. | Sopralene Flam 180 GR | 3 Tested Systems 3 Tested Systems 4 Tested Systems 1 Tested System 3 Tested Systems 3 Tested Systems 3 Tested Systems 2 Tested Systems |
-1.80 -2.40 -2.00 ---- -1.60 -2.40 -1.90 -1.80 |
-3.40 -5.20 -6.20 -2.40 -3.20 -5.20 -4.80 -2.40 |
-37.00 -50.00 -42.00 ---- -33.00 -50.00 -40.00 -37.0 |
-70.00 -108.00 -130.00 -50.00 -67.00 -108.00 -100.00 -50.00 |
Steel Steel Steel Plywood Plywood Steel Steel Steel |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRU168540 PUB-DRU168534 PUB-DRU206751 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 |
Soprema Inc. | Sopralene Flam 250 GR | 3 Tested Systems 3 Tested Systems 4 Tested Systems 1 Tested System 3 Tested Systems 3 Tested Systems 3 Tested Systems 2 Tested Systems |
-1.80 -2.40 -2.00 ---- -1.60 -2.40 -1.90 -1.80 |
-3.40 -5.20 -6.20 -2.40 -3.20 -5.20 -4.80 -2.40 |
-37.00 -50.00 -42.00 ---- -33.00 -50.00 -40.00 -37.0 |
-70.00 -108.00 -130.00 -50.00 -67.00 -108.00 -100.00 -50.00 |
Steel Steel Steel Plywood Plywood Steel Steel Steel |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRU168540 PUB-DRU168534 PUB-DRU206751 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 |
Soprema Inc. | Sopralene Mammouth GR | 3 Tested Systems 3 Tested Systems 4 Tested Systems 1 Tested System 3 Tested Systems 3 Tested Systems 3 Tested Systems 2 Tested Systems |
-1.80 -2.40 -2.00 ---- -1.60 -2.40 -1.90 -1.80 |
-3.40 -5.20 -6.20 -2.40 -3.20 -5.20 -4.80 -2.40 |
-37.00 -50.00 -42.00 ---- -33.00 -50.00 -40.00 -37.0 |
-70.00 -108.00 -130.00 -50.00 -67.00 -108.00 -100.00 -50.00 |
Steel Steel Steel Plywood Plywood Steel Steel Steel |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRU168540 PUB-DRU168534 PUB-DRU206751 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 |
Soprema Inc. | Sopraply Traffic Cap 560 | 3 Tested Systems 3 Tested Systems 3 Tested Systems 3 Tested Systems 2 Tested Systems |
-1.8 -2.4 -2.4 -1.9 -1.8 |
-3.4 -5.2 -5.2 -4.8 -2.4 |
-37 -50 -50 -40 -37 |
-70 -108 -108 -100 -50 |
Steel Steel Steel Steel Steel |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 |
Soprema Inc. | Sopraply Traffic Cap FR 561 | 3 Tested Systems 3 Tested Systems 3 Tested Systems 3 Tested Systems 2 Tested Systems |
-1.8 -2.4 -2.4 -1.9 -1.8 |
-3.4 -5.2 -5.2 -4.8 -2.4 |
-37 -50 -50 -40 -37 |
-70 -108 -108 -100 -50 |
Steel Steel Steel Steel Steel |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 |
Soprema Inc. | SopraStar Flam HD GR | 3 Tested Systems 3 Tested Systems 4 Tested Systems 1 Tested System 3 Tested Systems 3 Tested Systems 3 Tested Systems 2 Tested Systems |
-1.80 -2.40 -2.00 ---- -1.60 -2.40 -1.90 -1.80 |
-3.40 -5.20 -6.20 -2.40 -3.20 -5.20 -4.80 -2.40 |
-37.00 -50.00 -42.00 ---- -33.00 -50.00 -40.00 -37.0 |
-70.00 -108.00 -130.00 -50.00 -67.00 -108.00 -100.00 -50.00 |
Steel Steel Steel Plywood Plywood Steel Steel Steel |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRU168540 PUB-DRU168534 PUB-DRU206751 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 |