Template:CSA A123.21 Wind Uplift Test Reports - AARS

Jump to: navigation, search

Template:CSA A123.21 Wind Uplift Test Reports - AARS

Revision as of 21:30, 21 April 2017 by James Klassen (talk | contribs) (Membranes)
USING TESTED ASSEMBLY REPORTS

The tables and products shown below provide basic material data related to roof assemblies tested for their performance in modulating and high winds, using the test method found in CSA A123.21. They also provide links to more information about the materials, including manufacturers' published Technical Data sheets. The reader is advised to use this information in conjunction with other RoofStar-accepted Materials, and with reference to roof system requirements derived from from appropriate wind uplift calculations (see the Wind-RCI calculator and reference notes and requirements outlined in Securing the Roof Assembly; also refer to the BC Building Code, Part 4 and Part 5).

The information on this page is not intended for use as a comparison of material performance or quality. Nor should this information be construed as an endorsement of the suitability of any given material for a particular application. It is the sole responsibility of the Design Authority to assess the performance capability and material suitability for specific design requirements.


Expand
To view materials in any section listed below, click on the EXPAND button located at the right hand side of this page

Membranes

SBS Membrane Systems
Base Membranes
Primary Material Secondary Materials & Deck Tested Assembly Report Data
Manufacturer Membrane Insulation
Overlay
Insulation Deck
Overlay
Deck Tested
Systems
kPa Psf Downloadable
Test Report
Test Facility Test Facility
Report No.
Low High Low High
Henry Company Canada Modified Plus G100 p / s ---- ---- ---- Steel 1 Tested System ---- -3.80 ---- -80.00 AARS Test Report 2 Exova 14-06-M0115-3, Revision 1 (S)
Henry Company Canada Modified Plus NP180 Tack ---- ---- ---- Steel 1 Tested System ---- -4.79 ---- -100.00 AARS Test Report 1 Exova 14-06-M0115-1B, Revision 1 (S)
IKO Industries Ltd. Modiflex HD-FS-Base ---- ---- ---- Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
----
----
----
-4.80
-2.40
-4.20
----
----
----
-100.00
-50.00
-87.00
AARS Test Report 1
AARS Test Report 2
AARS Test Report 3
exp. Service Inc. PUB-DRU292547
PUB-DRU285762
PUB-DRU285764
IKO Industries Ltd. Modiflex HD-SS-Base ---- ---- ---- Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
----
----
----
-4.80
-2.40
-4.20
----
----
----
-100.00
-50.00
-87.00
AARS Test Report 1
AARS Test Report 2
AARS Test Report 3
exp. Service Inc. PUB-DRU292547
PUB-DRU285762
PUB-DRU285764
IKO Industries Ltd. Modiflex MF-95 F/S ---- ---- ---- Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
----
----
----
-4.80
-2.40
-4.20
----
----
----
-100.00
-50.00
-87.00
AARS Test Report 1
AARS Test Report 2
AARS Test Report 3
exp. Service Inc. PUB-DRU292547
PUB-DRU285762
PUB-DRU285764
IKO Industries Ltd. Modiflex MF-95 S/S ---- ---- ---- Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
----
----
----
-4.80
-2.40
-4.20
----
----
----
-100.00
-50.00
-87.00
AARS Test Report 1
AARS Test Report 2
AARS Test Report 3
exp. Service Inc. PUB-DRU292547
PUB-DRU285762
PUB-DRU285764
IKO Industries Ltd. Modiflex MP-180 F/S ---- ---- ---- Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
----
----
----
-4.80
-2.40
-4.20
----
----
----
-100.00
-50.00
-87.00
AARS Test Report 1
AARS Test Report 2
AARS Test Report 3
exp. Service Inc. PUB-DRU292547
PUB-DRU285762
PUB-DRU285764
IKO Industries Ltd. Modiflex MP-180 SS ---- ---- ---- Steel
Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
1 Tested System
----
----
----
----
-4.80
-2.40
-4.20
-1.40
----
----
----
----
-100.00
-50.00
-87.00
-29.00
AARS Test Report 1
AARS Test Report 2
AARS Test Report 3
AARS Test Report 2
exp. Service Inc. PUB-DRU292547
PUB-DRU285762
PUB-DRU285764
PUB-DRU 292025
IKO Industries Ltd. Torchflex TP-180 FF ---- ---- ---- Steel
Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
1 Tested System
----
----
----
----
-4.80
-2.40
-4.20
-2.50
----
----
----
----
-100.00
-50.00
-87.00
-53.00
AARS Test Report 1
AARS Test Report 2
AARS Test Report 3
AARS Test Report 1
exp. Service Inc. PUB-DRU292547
PUB-DRU285762
PUB-DRU285764
PUB-DRU278985 REV
Soprema Inc. Elastophene 180 S ---- ---- ---- Steel
Steel
1 Tested System
1 Tested System
----
----
-3.00
-2.40
----
----
-63.00
-50.00
AARS Test Report 4
AARS Test Report 5
exp. Service Inc. PUB-DRU212868
PUB-DRU210983
Soprema Inc. Sopralene 180 S ---- ---- ---- Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
----
----
----
-3.00
-2.40
-3.00
----
----
----
-63.00
-50.00
-62.00
AARS Test Report 4
AARS Test Report 5
AARS Test Report 9
exp. Service Inc. PUB-DRU212868
PUB-DRU210983
PUB-DRU229544
Soprema Inc. Colply Base 410 ---- ---- ---- Steel 1 Tested System ---- -2.40 ---- -50.00 AARS Test Report 5 exp. Service Inc. PUB-DRU210983
Soprema Inc. Elastophene 180 PS ---- ---- ---- Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
----
----
----
-3.00
-2.40
-3.00
----
----
----
-63.00
-50.00
-62.00
AARS Test Report 4
AARS Test Report 5
AARS Test Report 9
exp. Service Inc. PUB-DRU212868
PUB-DRU210983
PUB-DRU229544
Soprema Inc. Elastophene PS ---- ---- ---- Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
----
----
----
-3.00
-2.40
-3.00
----
----
----
-63.00
-50.00
-62.00
AARS Test Report 4
AARS Test Report 5
AARS Test Report 9
exp. Service Inc. PUB-DRU212868
PUB-DRU210983
PUB-DRU229544
Soprema Inc. Elastophene Flam ---- ---- ---- Steel
Steel
Steel
Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
2 Tested Systems
3 Tested Systems
2 Tested Systems
----
----
----
-3.40
-2.40
-1.90
-4.30
-4.00
-4.30
-4.80
-4.60
-3.90
----
----
----
-72.00
-50.00
-40.00
-87.30
-83.30
-90.00
-100.00
-96.00
-83.00
AARS Test Report 1
AARS Test Report 2
AARS Test Report 7
AARS Test Report 8
AARS Test Report 10
AARS Test Report 11
exp. Service Inc. RP-DRU210754
RAP-DRU240663
PUB-DRC303964
PUB-DRU240661
PUB-DRU229544
PUB-DRU220544
Soprema Inc. Sopraflash Flam Stick ---- ---- ---- Steel 1 Tested System ---- -3.00 ---- -63.00 AARS Test Report 6 exp. Service Inc. PUB-DRU209338
Soprema Inc. Sopralene 180 PS ---- ---- ---- Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
----
----
----
-3.00
-2.40
-3.00
----
----
----
-63.00
-50.00
-62.00
AARS Test Report 4
AARS Test Report 5
AARS Test Report 9
exp. Service Inc. PUB-DRU212868
PUB-DRU210983
PUB-DRU229544
Soprema Inc. Sopralene 250 S ---- ---- ---- Steel
Steel
1 Tested System
1 Tested System
----
----
-3.00
-2.40
----
----
-63.00
-50.00
AARS Test Report 4
AARS Test Report 5
exp. Service Inc. PUB-DRU212868
PUB-DRU210983
Soprema Inc. Sopralene Flam 180 ---- ---- ---- Steel
Steel
Steel
Steel
Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
2 Tested Systems
1 Tested System
3 Tested Systems
2 Tested Systems
----
----
----
-3.40
----
-2.40
-1.90
-4.30
-4.00
-4.30
-4.80
-3.00
-4.60
-3.90
----
----
----
-72.00
----
-50.00
-40.00
-87.30
-83.30
-90.00
-100.00
-62.00
-96.00
-83.00
AARS Test Report 1
AARS Test Report 2
AARS Test Report 7
AARS Test Report 8
AARS Test Report 9
AARS Test Report 10
AARS Test Report 11
exp. Service Inc. RP-DRU210754
RAP-DRU240663
PUB-DRC303964
PUB-DRU240661
PUB-DRU228011
PUB-DRU229544
PUB-DRU220544
Soprema Inc. Sopralene Flam 250 ---- ---- ---- Steel
Steel
Steel
Steel
Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
2 Tested Systems
1 Tested System
3 Tested Systems
2 Tested Systems
----
----
----
-3.40
---
-2.40
-1.90
-4.30
-4.00
-4.30
-4.80
-3.00
-4.60
-3.90
----
----
----
-72.00
----
-50.00
-40.00
-87.30
-55.50
-90.00
-100.00
-62.00
-96.00
-83.00
AARS Test Report 1
AARS Test Report 2
AARS Test Report 7
AARS Test Report 8
AARS Test Report 9
AARS Test Report 10
AARS Test Report 11
exp. Service Inc. RP-DRU210754
RAP-DRU240663
PUB-DRC303964
PUB-DRU240661
PUB-DRU228011
PUB-DRU229544
PUB-DRU220544
Soprema Inc. Sopraply Base 510 ---- ---- ---- Steel 1 Tested System ---- -3.00 ---- -62.00 AARS Test Report 9 exp. Service Inc. PUB-DRU228011
Soprema Inc. Sopraply Base 520 ---- ---- ---- Steel
Steel
Steel
Steel
Steel
Steel
1 Tested System
1 Tested System
1 Tested System
2 Tested Systems
3Tested Systems
2 Tested Systems
----
----
----
-3.40
-2.40
-1.90
-4.30
-4.00
-4.30
-4.80
-4.60
-3.90
----
----
----
-72.00
-50.00
-40.00
-87.30
-83.30
-90.00
-100.00
-96.00
-83.00
AARS Test Report 1
AARS Test Report 2
AARS Test Report 7
AARS Test Report 8
AARS Test Report 10
AARS Test Report 11
exp. Service Inc. RP-DRU210754
RAP-DRU240663
PUB-DRC303964
PUB-DRU240661
PUB-DRU229544
PUB-DRU220544
Expand
Cap Membranes
EPDM Membrane Systems
EPDM/Elastomeric Membranes (under development)
TPO/PVC Membrane Systems
TPO (under development)
PVC (under development)