USING TESTED ASSEMBLY REPORTS
The tables and products shown below provide basic material data related to roof assemblies tested for their performance in modulating and high winds, using the test method found in CSA A123.21. They also provide links to more information about the materials, including manufacturers' published Technical Data sheets. The reader is advised to use this information in conjunction with other RoofStar-accepted Materials, and with reference to roof system requirements derived from from appropriate wind uplift calculations (see the Wind-RCI calculator and reference notes and requirements outlined in Securing the Roof Assembly; also refer to the BC Building Code, Part 4 and Part 5). The information on this page is not intended for use as a comparison of material performance or quality. Nor should this information be construed as an endorsement of the suitability of any given material for a particular application. It is the sole responsibility of the Design Authority to assess the performance capability and material suitability for specific design requirements. Roof Assemblies are classified according to three different approaches to securement: MARS (Mechanically Attached Roof Systems), PARS (Partially Adhered Roof Systems), and AARS (Adhesive Applied Roof Systems). For a full explanation of these and other key details pertinent to an understanding of the test reports, visit Securing the Roof Assembly. In the tables below, the following definitions apply:
How to Use the Tables
|
1 SBS Membrane Systems
- The tables on the adjacent tabs display data and links to Tested Assembly Reports listed by the membrane type shown on the tab. These are reports that detail the makeup and performance of roof systems tested using the CSA-A123.21 Standard test method for the dynamic wind uplift resistance of membrane-roofing systems (latest edition). Use the maximum wind uplift values that equal or exceed the highest Specified Wind Loads; these are calculated using either the online Wind-RCI calculator or through manual engineering calculations (see the British Columbia Building Code, Division B, Part 4 (4.1.7 Specified Wind Loads));
(NOTE: while the reports show two different values for tested maximum assembly strength, the RPM tables display only the values adjusted for the required safety factor of 1.5) - Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report. It will break down the assembly by its components. Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the RoofStar Guarantee Program (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer);
- In cases where a tested Secondary material is not accepted by the RoofStar Guarantee Program, look for alternates which often are published in the each report. In the absence of published alternates, consult the manufacturer of the Tested Assembly for alternates that are accepted by the RoofStar Guarantee Program, and obtain the manufacturer's written approval.
Primary Material | Secondary Materials & Deck | Tested Assembly Report Data | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer | Membrane | Insulation Overlay |
Insulation | Deck Overlay |
Deck | Tested Systems |
kPa | Psf | Downloadable Test Report |
Test Facility | Test Facility Report No. | ||||
Low | High | Low | High | ||||||||||||
IKO Industries Ltd. | Fast-N-Stick-180 Base | ---- | ---- | ---- | Steel | 2 | -1.90 | -4.8 | -40.00 | -100.00 | MARS Test Report 1 | exp. Service Inc. | PUB-DRU292551 | ||
IKO Industries Ltd. | Fast-N-Stick HD Base | ---- | ---- | ---- | Steel | 3 | -2.40 | -5.10 | -50.00 | -106.00 | MARS Test Report 2 | exp. Service Inc. | PUB-DRU285771 | ||
Soprema Inc. | Soprafix Base 630 | ---- | ---- | ---- | Steel Steel Steel Steel |
4 1 3 4 |
-2.00 --- -1.60 -2.00 |
-6.20 -2.40 -3.20 -6.20 |
-42.00 --- -33.00 -42.00 |
-130.00 -50.00 -67.00 -130.00 |
MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 10 |
exp. Service Inc. | PUB-DRU168540 PUB-DRU168534 PUB-DRU206751 PUB-DRU339156 |
Primary Material | Primary Material | Tested Assembly Report Data | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer | Membrane | Insulation Overlay |
Insulation | Deck Overlay |
Deck | Tested Systems |
kPa | Psf | Downloadable Test Report |
Test Facility | Test Facility Report No. | ||||
Low | High | Low | High | ||||||||||||
IKO Industries Ltd. | Armourcool Granular TP-HD Cap | ---- | ---- | ---- | Steel Steel |
2 3 |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 | ||
IKO Industries Ltd. | Torchflex TP-180 Cap | ---- | ---- | ---- | Steel Steel |
2 3 |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 | ||
IKO Industries Ltd. | Torchflex TP-250 Cap 5mm | ---- | ---- | ---- | Steel Steel |
2 3 |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 | ||
IKO Industries Ltd. | Torchflex TP-250 Cap | ---- | ---- | ---- | Steel Steel |
2 3 |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 | ||
IKO Industries Ltd. | Torchflex TP-HD-Cap | ---- | ---- | ---- | Steel Steel |
2 3 |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 | ||
IKO Industries Ltd. | Prevent TP 250 Cap 4 mm | ---- | ---- | ---- | Steel Steel |
2 3 |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 | ||
IKO Industries Ltd. | Prevent TP-HD-Cap | ---- | ---- | ---- | Steel Steel |
2 3 |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 | ||
IKO Industries Ltd. | Prevent Premium TP 250 Cap 4 mm | ---- | ---- | ---- | Steel Steel |
2 3 |
-1.90 -2.40 |
-4.80 -5.10 |
-40.00 -50.00 |
-100.00 -106.00 |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU292551 PUB-DRU285771 | ||
Soprema Inc. | Soprafix Traffic Cap 660 | ---- | ---- | ---- | Steel Steel Steel Plywood Plywood Steel Steel Steel |
3 3 4 1 3 3 3 2 |
-1.80 -2.40 -2.00 ---- -1.60 -2.40 -1.90 -1.80 |
-3.40 -5.20 -6.20 -2.40 -3.20 -5.20 -4.80 -2.40 |
-37.00 -50.00 -42.00 ---- -33.00 -50.00 -40.00 -37.0 |
-70.00 -108.00 -130.00 -50.00 -67.00 -108.00 -100.00 -50.00 |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRU168540 PUB-DRU168534 PUB-DRU206751 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 | ||
Soprema Inc. | Soprafix Traffic Cap FR 661 | ---- | ---- | ---- | Steel Steel Steel Plywood Plywood Steel Steel Steel |
3 3 4 1 3 3 3 2 |
-1.80 -2.40 -2.00 ---- -1.60 -2.40 -1.90 -1.80 |
-3.40 -5.20 -6.20 -2.40 -3.20 -5.20 -4.80 -2.40 |
-37.00 -50.00 -42.00 ---- -33.00 -50.00 -40.00 -37.0 |
-70.00 -108.00 -130.00 -50.00 -67.00 -108.00 -100.00 -50.00 |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRU168540 PUB-DRU168534 PUB-DRU206751 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 | ||
Soprema Inc. | Soprafix Unilay 750 | ---- | ---- | ---- | Steel | 4 | -2 | -5.2 | -41 | -108 | MARS Test Report 7 | exp. Service Inc. | PUB-DRU168549 | ||
Soprema Inc. | Sopralene Flam 180 GR | ---- | ---- | ---- | Steel Steel Steel Plywood Plywood Steel Steel Steel |
3 3 4 1 3 3 3 2 |
-1.80 -2.40 -2.00 ---- -1.60 -2.40 -1.90 -1.80 |
-3.40 -5.20 -6.20 -2.40 -3.20 -5.20 -4.80 -2.40 |
-37.00 -50.00 -42.00 ---- -33.00 -50.00 -40.00 -37.0 |
-70.00 -108.00 -130.00 -50.00 -67.00 -108.00 -100.00 -50.00 |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRU168540 PUB-DRU168534 PUB-DRU206751 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 | ||
Soprema Inc. | Sopralene Flam 250 GR | ---- | ---- | ---- | Steel Steel Steel Plywood Plywood Steel Steel Steel |
3 3 4 1 3 3 3 2 |
-1.80 -2.40 -2.00 ---- -1.60 -2.40 -1.90 -1.80 |
-3.40 -5.20 -6.20 -2.40 -3.20 -5.20 -4.80 -2.40 |
-37.00 -50.00 -42.00 ---- -33.00 -50.00 -40.00 -37.0 |
-70.00 -108.00 -130.00 -50.00 -67.00 -108.00 -100.00 -50.00 |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRU168540 PUB-DRU168534 PUB-DRU206751 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 | ||
Soprema Inc. | Sopralene Mammouth GR | ---- | ---- | ---- | Steel Steel Steel Plywood Plywood Steel Steel Steel |
3 3 4 1 3 3 3 2 |
-1.80 -2.40 -2.00 ---- -1.60 -2.40 -1.90 -1.80 |
-3.40 -5.20 -6.20 -2.40 -3.20 -5.20 -4.80 -2.40 |
-37.00 -50.00 -42.00 ---- -33.00 -50.00 -40.00 -37.0 |
-70.00 -108.00 -130.00 -50.00 -67.00 -108.00 -100.00 -50.00 |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRU168540 PUB-DRU168534 PUB-DRU206751 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 | ||
Soprema Inc. | Sopraply Traffic Cap 560 | ---- | ---- | ---- | Steel Steel Steel Steel Steel |
3 3 3 3 2 |
-1.8 -2.4 -2.4 -1.9 -1.8 |
-3.4 -5.2 -5.2 -4.8 -2.4 |
-37 -50 -50 -40 -37 |
-70 -108 -108 -100 -50 |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 | ||
Soprema Inc. | Sopraply Traffic Cap FR 561 | ---- | ---- | ---- | Steel Steel Steel Steel Steel |
3 3 3 3 2 |
-1.8 -2.4 -2.4 -1.9 -1.8 |
-3.4 -5.2 -5.2 -4.8 -2.4 |
-37 -50 -50 -40 -37 |
-70 -108 -108 -100 -50 |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 | ||
Soprema Inc. | SopraStar Flam HD GR | ---- | ---- | ---- | Steel Steel Steel Plywood Plywood Steel Steel Steel |
3 3 4 1 3 3 3 2 |
-1.80 -2.40 -2.00 ---- -1.60 -2.40 -1.90 -1.80 |
-3.40 -5.20 -6.20 -2.40 -3.20 -5.20 -4.80 -2.40 |
-37.00 -50.00 -42.00 ---- -33.00 -50.00 -40.00 -37.0 |
-70.00 -108.00 -130.00 -50.00 -67.00 -108.00 -100.00 -50.00 |
MARS Test Report 1 MARS Test Report 2 MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 MARS Test Report 8 MARS Test Report 9 |
exp. Service Inc. | PUB-DRU168525 PUB-DRU168520 PUB-DRU168540 PUB-DRU168534 PUB-DRU206751 PUB-DRC304890 PUB-DRU168553 PUB-DRU209321 |
Manufacturer | Product Name | Number of Tested Systems (per report) |
kPa (Low) | kPa (High) | Psf (Low) | Psf (High) | Deck Type | Downloadable Test Report | Test Facility | Test Facility Report No. |
---|---|---|---|---|---|---|---|---|---|---|
Soprema Inc. | Soprafix Unilay 750 | 4 Tested Systems 4 Tested Systems |
-2.00 -2.00 |
-5.20 -5.20 |
-41.00 -41.00 |
-108.00 -108.00 |
Steel Steel |
MARS Test Report 7 MARS Test Report 14 |
exp. Service Inc. | PUB-DRU168549 SOPI-216809-T10 / SOPI-019-059-000 |
2 EPDM Membrane Systems
- The tables on the adjacent tabs display data and links to Tested Assembly Reports listed by the membrane type shown on the tab. These are reports that detail the makeup and performance of roof systems tested using the CSA-A123.21 Standard test method for the dynamic wind uplift resistance of membrane-roofing systems (latest edition). Use the maximum wind uplift values that equal or exceed the highest Specified Wind Loads; these are calculated using either the online Wind-RCI calculator or through manual engineering calculations (see the British Columbia Building Code, Division B, Part 4 (4.1.7 Specified Wind Loads));
(NOTE: while the reports show two different values for tested maximum assembly strength, the RPM tables display only the values adjusted for the required safety factor of 1.5) - Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report. It will break down the assembly by its components. Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the RoofStar Guarantee Program (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer);
- In cases where a tested Secondary material is not accepted by the RoofStar Guarantee Program, look for alternates which often are published in the each report. In the absence of published alternates, consult the manufacturer of the Tested Assembly for alternates that are accepted by the RoofStar Guarantee Program, and obtain the manufacturer's written approval.
Manufacturer | Product Name | Number of Tested Systems (per report) |
kPa (Low) | kPa (High) | Psf (Low) | Psf (High) | Deck Type | Downloadable Test Report | Test Facility | Test Facility Report No. |
---|---|---|---|---|---|---|---|---|---|---|
Firestone Building Products | Rubbergard EPDM Membrane | 1 Tested System 1 Tested System |
---- ---- |
-2.90 -3.70 |
---- ---- |
-60.00 -67.00 |
Steel | MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU283221 PUB-DRU303359 |
Firestone Building Products | Rubbergard ECO White EPDM Membrane | 1 Tested System 1 Tested System |
---- ---- |
-2.90 -3.70 |
---- ---- |
-60.00 -67.00 |
Steel | MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-DRU283221 PUB-DRU303359 |
3 TPO Membranes
- The tables on the adjacent tabs display data and links to Tested Assembly Reports listed by the membrane type shown on the tab. These are reports that detail the makeup and performance of roof systems tested using the CSA-A123.21 Standard test method for the dynamic wind uplift resistance of membrane-roofing systems (latest edition). Use the maximum wind uplift values that equal or exceed the highest Specified Wind Loads; these are calculated using either the online Wind-RCI calculator or through manual engineering calculations (see the British Columbia Building Code, Division B, Part 4 (4.1.7 Specified Wind Loads));
(NOTE: while the reports show two different values for tested maximum assembly strength, the RPM tables display only the values adjusted for the required safety factor of 1.5) - Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report. It will break down the assembly by its components. Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the RoofStar Guarantee Program (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer);
- In cases where a tested Secondary material is not accepted by the RoofStar Guarantee Program, look for alternates which often are published in the each report. In the absence of published alternates, consult the manufacturer of the Tested Assembly for alternates that are accepted by the RoofStar Guarantee Program, and obtain the manufacturer's written approval.
Manufacturer | Product Name | Number of Tested Systems (per report) |
kPa (Low) | kPa (High) | Psf (Low) | Psf (High) | Deck Type | Downloadable Test Report | Test Facility | Test Facility Report No. |
---|---|---|---|---|---|---|---|---|---|---|
Carlisle Syntec Systems Canada | Sure-Weld 45 mil TPO Membrane | 1 Tested System 1 Tested System |
---- ---- |
-3.40 -3.40 |
---- ---- |
-70.00 -71.00 |
Steel Steel |
MARS Test Report 3 MARS Test Report 4 |
exp. Service Inc. | PUB-DRU236018 PUB-DRU168402 |
Firestone Building Products | Ultraply 1.2 mm TPO Membrane | 1 Tested System 2 Tested Systems 1 Tested System 1 Tested System |
---- -3.80 ---- ---- |
-3.20 -4.20 -3.80 -3.00 |
---- -80.00 ---- ---- |
-67.00 -87.00 -80.00 -63.00 |
Steel Steel Steel Steel |
MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 |
exp. Service Inc. | PUB-DRU303384 PUB-DRU168455 PUB-DRU303385 PUB-DRU168431 |
Firestone Building Products | UltraPly 1.6 mm TPO Membrane | 1 Tested System 2 Tested Systems 1 Tested System 1 Tested System |
---- -3.80 ---- ---- |
-3.20 -4.20 -3.80 -3.00 |
---- -80.00 ---- ---- |
-67.00 -87.00 -80.00 -63.00 |
Steel Steel Steel Steel |
MARS Test Report 3 MARS Test Report 4 MARS Test Report 5 MARS Test Report 6 |
exp. Service Inc. | PUB-DRU303384 PUB-DRU168455 PUB-DRU303385 PUB-DRU168431 |
Johns Manville Corporation | JM TPO-45 | 1 Tested System | ---- | -3.6 -5.0 |
---- | -75.0 -105.0 |
Steel Steel |
MARS Test Report 3 MARS Test Report 4 |
exp. Service Inc. | PUB-DRU292367 PUB-DRU292360 |
Johns Manville Corporation | JM TPO-60 | 1 Tested System | ---- | -3.6 -5.0 |
---- | -75.0 -105.0 |
Steel Steel |
MARS Test Report 3 MARS Test Report 4 |
exp. Service Inc. | PUB-DRU292367 PUB-DRU292360 |
Johns Manville Corporation | JM TPO-80 | 1 Tested System | ---- | -3.6 -5.0 |
---- | -75.0 -105.0 |
Steel Steel |
MARS Test Report 3 MARS Test Report 4 |
exp. Service Inc. | PUB-DRU292367 PUB-DRU292360 |
4 PVC Membranes
Manufacturer | Product Name | Number of Tested Systems (per report) |
kPa (Low) | kPa (High) | Psf (Low) | Psf (High) | Deck Type | Downloadable Test Report | Test Facility | Test Facility Report No. |
---|---|---|---|---|---|---|---|---|---|---|
Carlisle Syntec Systems Canada | Sure-Flex 50 mil PVC Membrane | 1 Tested System 1 Tested System |
---- ---- |
-3.40 -2.30 |
---- ---- |
-70.00 -47.00 |
Steel Steel |
MARS Test Report 1 MARS Test Report 2 |
exp. Service Inc. | PUB-CRU237226 RAP-DRU208111 |
Johns Manville Corporation | JM PVC (60 mil.) | 1 Tested System | ---- | -3.60 | ---- | -75.0 | Steel | MARS Test Report 1 | exp. Service Inc. | PUB-DRU292249 |
Johns Manville Corporation | JM PVC (80 mil.) | 1 Tested System | ---- | -3.60 | ---- | -75.0 | Steel | MARS Test Report 2 | exp. Service Inc. | PUB-DRU292249 |
5 Insulation Overlays
Manufacturer | Product Name | Number of Tested Systems (per report) |
kPa (Low) | kPa (High) | Psf (Low) | Psf (High) | Deck Type | Downloadable Test Report | Test Facility | Test Facility Report No. |
---|---|---|---|---|---|---|---|---|---|---|
Soprema Inc. | Soprasmart ISO HD 180 | 3 Tested Systems | -2.40 | -5.20 | -50.00 | -108.00 | Steel | MARS Test Report 6 | exp. Service Inc. | PUB-DRC304890 |
Soprema Inc. | Soprasmart Board 180 | 3 Tested Systems | -2.40 | -5.20 | -50.00 | -108.00 | Steel | MARS Test Report 6 | exp. Service Inc. | PUB-DRC304890 |
Soprema Inc. | Xpress Board HD | 3 Tested Systems 3 Tested Systems |
-1.90 -1.90 |
-4.80 -4.80 |
-40.00 -40.00 |
-100.00 -100.00 |
Steel | MARS Test Report 8 MARS Test Report 11 |
exp. Service Inc. | PUB-DRU168553 PUB-DRU339785 |
Soprema Inc. | Xpress ISO | 2 Tested Systems 2 Tested Systems |
-1.80 -1.80 |
-2.40 -2.40 |
-37.00 -37.00 |
-50.00 -50.00 |
Steel | MARS Test Report 9 MARS Test Report 13 |
exp. Service Inc. | PUB-DRU209321 SOPI-020-059-010 |
Soprema Inc. | Soprabase HD | 3 Tested Systems | -2.40 | -5.20 | -50.00 | -108.00 | Steel | MARS Test Report 12 | exp. Service Inc. | SOPI-019-059-400 |