SBS Roof System Details

Jump to: navigation, search

SBS Roof System Details

Revision as of 20:31, 10 June 2022 by James Klassen (talk | contribs)



Division D - Construction Details

Construction Details for SBS-modified Bitumen Membrane Roof Systems
The drawings linked on this page are intended to represent a variety of SBS-modified Bitumen Membrane roof system applications while remaining generic with regards to manufacturers’ specific application specifications. They do not represent all possible manufacturer application roof system designs. Consult each manufacturers’ specifications and the RoofStar Guarantee Standards to develop a system acceptable to both the manufacturer and the RoofStar Guarantee Program.
For further information about SBS-modified Bitumen Membrane System designs and requirements, see the Standard for SBS-modified Bitumen Membrane Roof Systems.
SBS Systems page thumb.JPG

Pdf.png

NOTE: 'PDF' shown after a file name below indicates a downloadable print sheet is available for Construction Details. Click on the detail link and look for the icon.


Part 11 - Drainage

General Requirements for Cast-iron Roof Drains ( Article 11.3.3.2.)
Cast Iron Drains
Flanged Insert-type Roof Drains ( Article 11.3.3.6.)
Flanged Drains (typical)
Flanged Drains (clamping)
Scuppers and Overflows ( Article 11.3.3.7.)
Open Wall Scupper
Through-wall Scupper

Part 12 - Penetrations and Curbs

General Requirements for Flashing Penetrations ( Article 12.3.2.1.)
Plumbing Vent
Two-part Cable Flashing
Multiple Penetration Flashing
Roof Anchors (typical)
Roof Anchors (conventional system)
Roof Anchors (PMRA)
Curbs, Sleepers, and Equipment Pads ( Article 12.3.2.4.)
Uninsulated Curb
Insulated Curb (Mechanical)
Equipment Sleeper
Railings, Ladders, and Other Attached Structures ( Article 12.3.2.7.)
Railing
Sealant Pockets ( Article 12.3.2.8.)
Sealant Pocket (typical)

Part 13 - Linear Metal Flashing

See the separate page, Construction Details for Linear Metal Flashings.

Part 14 - The Roof as a Platform

Structures and Equipment ( Article 14.3.2.7.)
Planter Wall ("pre-curb")