Search results

Jump to: navigation, search

Search results

  • ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==
    416 KB (56,532 words) - 22:23, 5 April 2024
  • ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==
    424 KB (57,418 words) - 22:20, 5 April 2024
  • ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==
    421 KB (57,062 words) - 22:20, 5 April 2024
  • ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==
    296 KB (41,811 words) - 22:23, 5 April 2024
  • ...e less than the percentage of slope provided by the insulation. A minimum slope of 1:50 (1/4" in 12") is strongly recommended. The exception is often drain ...r bearing walls. Building settlement can often cause slopes to change and low spots to appear on the roof surface.
    20 KB (2,969 words) - 16:06, 9 September 2021
  • [[Section:D. Application: Low Slope Roofs|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''EPDM Application''] [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back
    1,011 bytes (124 words) - 21:30, 16 September 2016
  • *low temperature flexibility ...aminated with metal foil for ultra-violet protection. As an alternative on roofs with minimal slopes, a pour coat and gravel surfacing may be installed over
    23 KB (3,307 words) - 15:57, 9 September 2021
  • [[Section:D. Application: Low Slope Roofs|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''TPO/PVC Application [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back
    1 KB (128 words) - 15:20, 19 September 2016
  • This section has been reprinted with the kind permission of: Many of the remarks in this section pertain to bituminous built-up roofs. However, data is also included on flexible membrane (&#8220;non-convention
    75 KB (11,617 words) - 21:00, 3 September 2021
  • ...ng ''deck'' structure (adapted from ''ASTM D6630-08 Standard Guide for Low slope Insulated Roof membrane Assembly Performance''). ...cle 3.1.3.4. in any of the waterproofing roof Standards for sheet membrane roofs, published in Division B of the RPM).
    76 KB (11,565 words) - 18:09, 26 January 2024
  • * improved low temperature flexibility ...fs|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Application: Low Slopes'']]
    1 KB (189 words) - 18:41, 4 January 2016
  • ...fs|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Application: Low Slopes'']]
    128 bytes (18 words) - 18:49, 4 January 2016
  • ...fs|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Application: Low Slopes'']]
    128 bytes (18 words) - 18:53, 4 January 2016
  • [[:Section:A. About|'''A. About''']] [[:Section:B. Essential Elements|'''B. Essential Elements''']]
    7 KB (990 words) - 20:54, 2 August 2016
  • '''NOTE''': This page is under development. Refer to the [[Section:G. Construction Details|'''SBS, EPDM or TPO/PVC Membrane Construction Detai [[Section:D. Application: Low Slope Roofs|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Other Flexible Memb
    696 bytes (92 words) - 01:13, 15 September 2016
  • Contact Address: See Membership List in Section 1. # Slope: Roof slopes which exceed &#189;" in 12" (4.2%) require the following:
    21 KB (3,147 words) - 19:39, 7 November 2016
  • Contact Address: See Membership List in Section 1. # Used in new construction and re-roofing of existing roofs.
    20 KB (3,027 words) - 23:04, 7 November 2016
  • ...amenity space is installed on top of it. An integrity scan typically uses low-voltage electrical current to detect even the smallest breaches in the roof :Electronic Leak Detection (ELD) utilizes low-voltage electrical current, typically conducted through wires installed in
    59 KB (8,538 words) - 18:07, 2 April 2024
  • ...amenity space is installed on top of it. An integrity scan typically uses low-voltage electrical current to detect even the smallest breaches in the roof :Electronic Leak Detection (ELD) utilizes low-voltage electrical current, typically conducted through wires installed in
    57 KB (8,227 words) - 18:02, 2 April 2024
  • ...amenity space is installed on top of it. An integrity scan typically uses low-voltage electrical current to detect even the smallest breaches in the roof :Electronic Leak Detection (ELD) utilizes low-voltage electrical current, typically conducted through wires installed in
    57 KB (8,227 words) - 18:07, 2 April 2024
  • ...amenity space is installed on top of it. An integrity scan typically uses low-voltage electrical current to detect even the smallest breaches in the roof :Electronic Leak Detection (ELD) utilizes low-voltage electrical current, typically conducted through wires installed in
    61 KB (8,812 words) - 18:01, 2 April 2024
  • ...neric&#8221; application specifications and details are not possible. This section of the manual contains both an overview of the products, their composition, ...generally be defined as either a THERMOSET (Section 6.1) or THERMOPLASTIC (Section 6.2).
    33 KB (4,674 words) - 16:01, 9 September 2021
  • ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==
    260 KB (36,048 words) - 21:32, 5 April 2024
  • ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==
    465 KB (62,116 words) - 21:20, 5 April 2024
  • ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==
    423 KB (57,312 words) - 21:21, 5 April 2024
  • ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==
    420 KB (56,956 words) - 21:23, 5 April 2024
  • ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==
    415 KB (56,426 words) - 21:31, 5 April 2024
  • ==Section 1.1. Design== ...s an insulated or uninsulated ''roof system'', designed and constructed on roofs using a sheet or liquid-applied membrane, to exclude water. This type of '
    235 KB (33,160 words) - 21:33, 5 April 2024
  • ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==
    294 KB (41,687 words) - 21:32, 5 April 2024
  • ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==
    466 KB (62,225 words) - 22:19, 5 April 2024
  • ...amenity space is installed on top of it. An integrity scan typically uses low-voltage electrical current to detect even the smallest breaches in the roof :Electronic Leak Detection (ELD) utilizes low-voltage electrical current, typically conducted through wires installed in
    61 KB (8,848 words) - 18:15, 2 April 2024
  • ...amenity space is installed on top of it. An integrity scan typically uses low-voltage electrical current to detect even the smallest breaches in the roof :Electronic Leak Detection (ELD) utilizes low-voltage electrical current, typically conducted through wires installed in
    59 KB (8,541 words) - 18:06, 2 April 2024
  • ...amenity space is installed on top of it. An integrity scan typically uses low-voltage electrical current to detect even the smallest breaches in the roof :Electronic Leak Detection (ELD) utilizes low-voltage electrical current, typically conducted through wires installed in
    57 KB (8,230 words) - 18:16, 2 April 2024
  • ...amenity space is installed on top of it. An integrity scan typically uses low-voltage electrical current to detect even the smallest breaches in the roof :Electronic Leak Detection (ELD) utilizes low-voltage electrical current, typically conducted through wires installed in
    57 KB (8,230 words) - 18:16, 2 April 2024
  • ...''''RoofStar 15-Year Guarantee''''' are listed in each relevant Part under Section 1. All '''''RoofStar 15-Year Guarantee''''' requirements must be read toge ==Section 1.1. Design==
    261 KB (36,152 words) - 22:24, 5 April 2024
  • ==Section 1.1. Design== ...s an insulated or uninsulated ''roof system'', designed and constructed on roofs using a sheet or liquid-applied membrane, to exclude water. This type of '
    236 KB (33,264 words) - 22:24, 5 April 2024