Search results

Jump to: navigation, search

Search results

  • ...rity <i class="fa fa-hand-o-right" aria-hidden="true"></i> <big>Materials by Manufacturer, Distributor or Certifying Authority</big>] ...Name <i class="fa fa-hand-o-right" aria-hidden="true"></i> <big>Materials by Product Name</big>]
    732 bytes (97 words) - 16:54, 19 August 2016
  • ...membrane, these products also offer the practical advantages of bituminous materials (i.e. they are generally compatible with asphalt products and may be useful ...and they tend to exhibit &#8220;plastic&#8221; properties. Thermosets are materials in which cross-linking of the molecules occurs and they tend to exhibit &#8
    22 KB (3,281 words) - 21:46, 17 July 2017
  • ...Siplast_NVS_Premix_Product_Info_Sheet.pdf '''Here'''] for '''NVS Premix''' materials handling and application instructions, :* Recover and existing roof system (consultant validated).
    3 KB (474 words) - 21:16, 12 February 2019
  • <big><big>Division C - Accepted Materials</big></big> | style="background-color: #ffffcc; column-width:100%" | {{Template:Accepted Materials Page Header}}
    1 KB (178 words) - 21:51, 7 September 2021
  • <big><big>Division C - Accepted Materials</big></big> *'''Accepted Materials'''
    22 KB (3,050 words) - 16:20, 12 December 2023
  • ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']]. ...a temperature of 1100<sup>o</sup>C (2000<sup>o</sup>F), the flame produced by liquid propane gas does an excellent melting job. But used incorrectly or
    14 KB (2,333 words) - 16:39, 9 February 2022
  • ...include (without limitation) the following (as they are applicable to the type of ''project''): ...by the RGC and listed in the '''''Roofing Practices Manual'''''. Accepted Materials include (without limitation)|| 2021-February-7 }}
    9 KB (1,253 words) - 17:05, 10 December 2021
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    416 KB (56,532 words) - 22:23, 5 April 2024
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    424 KB (57,418 words) - 22:20, 5 April 2024
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    421 KB (57,062 words) - 22:20, 5 April 2024
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    296 KB (41,811 words) - 22:23, 5 April 2024
  • <big><big>Division C - Accepted Materials</big></big> <big><big><big>by Active Member Name</big></big></big><br>
    5 KB (684 words) - 14:23, 27 October 2023
  • ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']]. ...kers, rain, snow, and ice. Dead loads include the deck itself, the roofing system, HVAC units and, possibly, landscaping. Most decks must also act as a diaph
    20 KB (2,969 words) - 16:06, 9 September 2021
  • ...s Part apply to all Standards for all ''projects'' unless expressly varied by the ''Guarantor'' under the terms of the Guarantee issued for a ''project'' ...ot Work. Some tools used in the course of Hot Work can ignite combustible materials, and some building environments are more sensitive to fire than others, suc
    11 KB (1,608 words) - 22:03, 3 May 2021
  • ...y system according to the weather-side surface, and are further divided by system categories - '''Roof Waterproofing Systems''', '''Water-shedding Systems''' :'''Division C: Accepted Materials'''
    15 KB (2,132 words) - 19:02, 18 August 2023
  • ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']]. ...igned to provide an interior environment (or shelter) that is not governed by the exterior environment. The roof is a fundamental component of this desig
    23 KB (3,279 words) - 15:42, 9 September 2021
  • | style="background-color: #ffffcc; column-width:100%" | {{Template:Accepted Materials Page Header}} ...sture detection company, whose moisture detection system has been reviewed by the RCABC Technical Committee and deemed to be suitable for inclusion in th
    2 KB (249 words) - 22:45, 9 November 2016
  • <big><big><big><big><big>Fasteners and Fastening Materials</big></big></big></big></big> ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']].
    7 KB (999 words) - 15:42, 9 September 2021
  • ...e printed and digital editions of Roofing BC, the trade magazine published by the RCABC. You can also watch the video presentation, “Blown Away: Code R ...and in shops and factories. The assembly and integration of these various materials and systems into a finished building requires tremendous coordination, nego
    21 KB (3,118 words) - 16:32, 16 March 2023
  • ...Systems Standard#PART_6|'''Air or Vapour Control Layers''']]: If required by design authority. ...fastened. See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manual''.
    3 KB (440 words) - 18:14, 27 October 2023
  • <big><big><big><big><big>BUR Materials</big></big></big></big></big> ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']].
    15 KB (2,293 words) - 15:33, 9 September 2021
  • <big><big><big><big><big>Waterproofing Materials</big></big></big></big></big> ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']].
    23 KB (3,307 words) - 15:57, 9 September 2021
  • ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']]. ...rom weather exposure to prevent &#8220;wicking&#8221; of moisture into the system. The surfacing material can also provide fire resistance, reflectivity or i
    8 KB (1,280 words) - 16:25, 9 September 2021
  • ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']]. ...w Chemical Co. Much of the initial research on these systems was conducted by the National Research Council of Canada during the late 1950's and early 19
    11 KB (1,624 words) - 16:21, 9 September 2021
  • | style="background-color: #ffffcc; column-width:100%" | {{Template:Accepted Materials Page Header}} ...a broad selection of overlays that could be used in a water-shedding roof system. However, not every material listed here may be suitable for this applicat
    1 KB (185 words) - 14:15, 27 July 2021
  • | style="background-color: #ffffcc; column-width:100%" | {{Template:Accepted Materials Page Header}} :'''See the tables below for tapered products offered by various manufacturers.'''
    2 KB (251 words) - 14:13, 27 July 2021
  • ...he [[Cedar Shake & Shingle Systems Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...ons for second nail. All ridges and hips shall be of the alternate overlap type and at the same exposure as the field of the roof. Each side shall be faste
    3 KB (493 words) - 21:06, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.
    4 KB (458 words) - 21:14, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications.
    4 KB (454 words) - 21:14, 7 September 2021
  • ...tion Layer''']]: Recommended over asphaltic underlays and / or as required by metal panel manufacturer. ....2.1.3. Fasteners |'''Exposed Fasteners''']]: High-domed gasketed cladding type screws compatible with metal roof panel.
    2 KB (297 words) - 18:04, 28 June 2022
  • ...me deck surface to provide a solid or continuous substrate for roof system materials. Here, a deck overlay is provided to support a continuous AVB layer. ...foam closures set in acceptable sealant with high domed gasketed cladding type screws at each standing rib.
    4 KB (540 words) - 17:25, 28 June 2022
  • ...rlayment|'''Underlayment''']]: The type of underlay required is determined by roof slope. ;(3) [[ASM Roof Systems Standard#8.1.3.4. Separation Between Materials|'''Vapour-permeable separation membrane''']]: Installed over insulation and
    3 KB (432 words) - 19:00, 28 June 2022
  • ...rlayment|'''Underlayment''']]: The type of underlay required is determined by roof slope. ;(4) [[ASM Roof Systems Standard#8.1.3.4. Separation Between Materials|'''Vapour-permeable separation membrane''']]: Installed over insulation and
    4 KB (537 words) - 17:35, 17 March 2023
  • ...rlayment|'''Underlayment''']]: The type of underlay required is determined by roof slope. ;(3) [[ASM Roof Systems Standard#8.1.3.4. Separation Between Materials|'''Vapour-permeable separation membrane''']]: Installed over insulation and
    4 KB (530 words) - 20:11, 28 June 2022
  • ...foam closures set in acceptable sealant with high domed gasketed cladding type screws at each standing rib. ...Standard#PART_13 |'''Metal Counter Flashing''']]: Must extend behind wall system and wall control layers. Stucco stops are not considered to be a counter fl
    3 KB (464 words) - 17:31, 28 June 2022
  • ...|'''Underlayment (lower)''']]: The type of underlay required is determined by roof slope. ..., which is tied into underlayment, to ensure any water intrusion into roof system drains into gutter.
    5 KB (611 words) - 18:17, 12 March 2024
  • <big><big><big><big><big>TPO | Conventionally Insulated System (Typical) ([[TPO_Roof_Systems_Standard#1.1.3.1._Permitted_Roof_Systems | Ar ...d depending on insulation thickness or when required as a thermal barrier by design authority.
    3 KB (383 words) - 21:38, 27 June 2022
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...ve: Proprietary primer or adhesive, application and quantities as directed by membrane manufacturers published application specifications.
    4 KB (527 words) - 21:15, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...ive: Proprietary primer or adhesive application and quantities as directed by Membrane Manufacturer's published application specifications.
    4 KB (527 words) - 21:16, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...tandard#WPINSULATION | '''Insulation''']]: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, compressive strength of 240 kpa (35 psi).
    4 KB (596 words) - 21:17, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...ve: Proprietary primer or adhesive, application and quantities as directed by membrane manufacturers published application specifications.
    4 KB (463 words) - 21:18, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...eel channel and concrete pins. Adhered membrane termination held in place by clamping pressure and pins.
    4 KB (475 words) - 21:21, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.
    4 KB (467 words) - 21:21, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.
    3 KB (413 words) - 21:22, 7 September 2021
  • A roof system is exposed to all manner of chemical and physical stress. The long-term eff * As-built drawings of construction details directly related to the roofing system, such as flashings, deck, etc.
    75 KB (11,617 words) - 21:00, 3 September 2021
  • :The ability of a membrane to resist being worn away by contact with a moving abrasive surface, such as foot traffic, mechanical eq :The process in which materials are exposed to a controlled environment where various phenomena &#8211; suc
    76 KB (11,565 words) - 18:09, 26 January 2024
  • :<u>Test Procedures for Evaluation of Materials:</u> == 11.2.2 <u>Significance of the Reported Physical Properties of Membrane Materials</u> ==
    11 KB (1,753 words) - 15:02, 4 May 2017
  • ...Roof Systems Standard#PART_5|'''Supporting Deck Overlay''']]: If required by design authority. ...Systems Standard#PART_6|'''Air or Vapour Control Layers''']]: If required by design authority.
    3 KB (334 words) - 18:01, 27 October 2023
  • ...Roof Systems Standard#PART_5|'''Supporting Deck Overlay''']]: If required by design authority. ...f Systems Standard#PART_6|'''Air or Vapour Control Layers''']]:If required by design authority.
    3 KB (402 words) - 17:50, 27 October 2023
  • | colspan="2" | <big>To view materials in any section listed below, click on the <span style="color:#6495ed">'''Ex ...terials'''] section of this Manual, as their performance is not guaranteed by the '''''RoofStar Guarantee Program'''''. For more about air and vapour ba
    5 KB (576 words) - 20:33, 26 July 2021

View (previous 50 | next 50) (20 | 50 | 100 | 250 | 500)