<big><big>Division C - Accepted Materials</big></big>
 +
<hr>
 +
<big><big><big><big><big>Roofs: Insulation Overlays</big></big></big></big></big><br>
 +
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
Line 18: Line 35:
 
* insulations that are too &#8220;soft&#8221; may result in delamination or damage to the membrane or insulation when exposed to heavy loads or traffic
 
* insulations that are too &#8220;soft&#8221; may result in delamination or damage to the membrane or insulation when exposed to heavy loads or traffic
 
* the solvents and adhesives used for flexible membranes may adversely affect the insulation.
 
* the solvents and adhesives used for flexible membranes may adversely affect the insulation.
 +
<br>
 +
====Asphaltic Overlays====
 +
{{Template:Materials - Insulation Overlay (Asphaltic Board)}}
  
 +
====Fibreglass-faced Silicon-treated Gypsum Core Overlays====
 +
{{Template:Materials - Insulation Overlay (Moisture-resistant Gypsum Core Boards)}}
  
<b>NOTE</b>: All hot asphalt-adhered asphaltic membranes (built-up roofing, modified bitumen, etc.) require an insulation overlay over heat sensitive insulations and heat insensitive foamed insulation. '''''RoofStar Guarantee Standards''''' for heat sensitive insulation<b> require</b> a two-layer overlay board for a five (5) or ten (10) year '''''RoofStar Guarantee'''''. The '''''RoofStar Guarantee Standards''''' <b>require</b> the use of a two-layer overlay board over heat sensitive insulation in all cases, and also <b>requires</b> a single-layer overlay board application over heat insensitive insulation for all hot asphalt-adhered membranes. For single-ply, non-asphaltic membrane roofing systems, the membrane manufacturer should be consulted for proprietary options.
+
====High-density Insulation Overlays====
 +
{{Template:Materials - Insulation Overlay (High-density)}}
  
<big><big>[[Insulation Joints and Overlay|Fibreboard]]</big></big>
+
====Membrane-laminated Overlays====
{{Template:Materials - Insulation Overlay (Fibreboard)}}
+
{{Template:Materials - Insulation Overlay (Membrane-laminated)}}
  
<big><big>[[Insulation Joints and Overlay|Proprietary Insulation Overlay Boards]]</big></big>
+
====Mineral Fibre Overlays====
{{Template:Materials - Insulation Overlay (Proprietary)}}
+
{{Template:Materials - Insulation Overlay (Mineral Fibre)}}
  
 +
====Fibreboard and Membrane-laminated Fibreboard Overlays====
 +
{{Template:Materials - Insulation Overlay (Fibreboard and Membrane-laminated Fibreboard)}}
 +
 +
</div>
 +
<div class="col-md-12">
 
<hr>
 
<hr>
  
 
+
[[Main Page | <i class="fa fa-home fa"></i> Home]]
[[Materials by Product Type |<i class="fa fa-chevron-circle-left" ></i> ''Accepted Materials'']]
+
</div>
 
+
{{Tempate:RPM Page Footer with Copyright and Current Date}}
 
 
[[Main Page|Home]]
 

Latest revision as of 18:08, 16 June 2023



Division C - Accepted Materials


Roofs: Insulation Overlays

Accepted Materials for a RoofStar Guarantee

The tables and products shown below provide basic material data and links to more information about the materials, including manufacturers' published Technical Data sheets, but this information is not intended for use as a comparison of material performance or quality. It is the sole responsibility of the Design Authority to assess the performance capability and material suitability for specific design requirements.

The materials listed are those which have been accepted by the RoofStar Guarantee Program (RCABC Guarantee Corp., or RGC) for use in a roof or grade-level waterproofing system that will qualify for a RoofStar Guarantee. The acceptance of these materials by the RGC (RoofStar Guarantee Program) in no way reflects on the quality or performance of other materials not listed.

The materials and guideline specifications are listed under the name of the manufacturer and/or supplier of the primary membrane material, with the exception of BUR membranes for which the reader will find RoofStar Guarantee Program guidelines on traditional built-up roofing systems (BUR) incorporating organic and glass felt primary membranes.

Insulation overlays are used to separate the roof membrane from the primary insulation, usually for one of two reasons:

  • to prevent the insulation from affecting the performance of the roof membrane
  • to prevent the roof membrane and / or the method of application from affecting the insulation

The insulation can affect the performance of the roof membrane in the following ways:

  • the insulation may be incompatible with the membrane, resulting in a loss of physical properties
  • different coefficients of thermal expansion may result in membrane splits / cracks.

The roof membrane and / or the method of application can affect the insulation in the following ways:

  • the insulation may not be capable of withstanding asphalt application temperatures and may “burn-out”
  • some insulations will not accommodate direct torch-applied membranes
  • insulations that are too “soft” may result in delamination or damage to the membrane or insulation when exposed to heavy loads or traffic
  • the solvents and adhesives used for flexible membranes may adversely affect the insulation.


Asphaltic Overlays

Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program
Manufacturer Product Name Thickness
(mm)
Thickness
(in.)
Dimensions
(mm)
Dimensions
(in.)
Compressive
Strength
(kPa)
Compressive
Strength
(psi)
Thermal
Resistance
(RSI/25.4 mm)
Thermal
Resistance
(R/inch)
Hal Industries Inc. Perma-Board 4.5 3/16 1000 x 2000 39 x 66 - - - -
IKO Industries Ltd. Protecto Board 4.5, 6.4, 12.7 3/16, 1/4, 1/2 1220 x 1520, 1220 x 2440 48 x 60, 48 x 96 - - - -
IKO Industries Ltd. Protectobase 95 4.5 3/16 - - - - - -
IKO Industries Ltd. Protectobase 180 4.5 3/16 915 x 2400 36 x 96 - - - -
Polyglass USA, Inc. Polyboard E 4.5, 6 3/16, 1/4 1220 x 1520 48 x 60, 48 x 96 - - - -
Polyglass USA, Inc. Polyboard W 4.5 3/16 1000 x 2000 40 x 80 - - - -
Soprema Inc. Sopraboard 4.5, 6.3 3/16, 1/4 1220 x 1520, 1220 x 2400 48 x 60, 48 x 96 - - - -

Fibreglass-faced Silicon-treated Gypsum Core Overlays

Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program
Manufacturer Product Name Thickness
(mm)
Thickness
(in.)
Dimensions
(mm)
Dimensions
(in.)
Compressive
Strength
(kPa)
Compressive
Strength
(psi)
Thermal
Resistance
(RSI/25.4 mm)
Thermal
Resistance
(R/inch)
Georgia-Pacific Canada Ltd. DensDeck® Roofboard 6.4, 12.7, 15.9 1/4, 1/2, 5/8 6.4, 12.7, 15.9 4 x 8 3447 - 6205 500 - 900 - 0.56
Georgia-Pacific Canada Ltd. DensDeck® Prime with EONIC Roof Board 6.4, 12.7, 15.9 1/4, 1/2, 5/8 6.4, 12.7, 15.9 4 x 8 3447 - 6205 500 - 900 - 0.56
USG (CGC) SecureRock Securerock Gypsum Fibre Roof Board - - - - - - - -
USG (CGC) SecureRock Securerock Glass-Mat Roof Board - - - - - - - -

High-density Insulation Overlays

Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program
Manufacturer Product Name Thickness
(mm)
Thickness
(in.)
Dimensions
(mm)
Dimensions
(in.)
Compressive
Strength
(kPa)
Compressive
Strength
(psi)
Thermal
Resistance
(RSI/25.4 mm)
Thermal
Resistance
(R/inch)
Carlisle Syntec Systems Canada SecurShield HD Plus 12.5 1/2 1220 x 2440 48 x 96 690 100 - 2.5
Elevate (fomerly Firestone) ISOGARD HD (Grade 1, 2) 12.5 1/2 1220 x 1220, 1220 x 2440 48 x 48, 48 x 96 ≥ 551, ≥ 827 ≥ 80, ≥ 120 0.44 2.5
Hunter Panels H-Shield HD 12.5 1/2 1220 x 2440 48 x 96 620 90 0.44 2.5
IKO Industries Ltd. IKOTherm Covershield 12.5 1/2 1220 x 2440 48 x 96 620 90 0.44 2.5
Johns Manville Corporation Retrofit Board 12.5 1/2 610 x 1220, 1220 x 1220, 1220 x 2440 24 x 48, 48 x 48, 48 x 96 255 37 0.46 2.64
Johns Manville Corporation Invinsa Roof Board 6.3 1/4 1220 x 1220, 1220 x 2440 48 x 48, 48 x 96 1034 150 - 1
Siplast, Inc. Paratherm HD 12.5 1/2 1220 x 1220, 1220 x 2440 48 x 48, 48 x 96 552 80 0.44 2.5
Siplast, Inc. Paratherm W HD 12.5 1/2 1220 x 1220, 1220 x 2440 48 x 48, 48 x 96 552 80 0.44 2.5
Soprema Inc. Sopra-Iso Plus HD 12.5 1/2 1220 x 1220, 1220 x 2440 48 x 48, 48 x 96 689 100 0.44 2.5

Membrane-laminated Overlays

Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program
N/P = Not Published
Manufacturer Product Name Thickness
(mm)
Thickness
(in.)
Dimensions
(mm)
Dimensions
(in.)
Compressive
Strength
(kPa)
Compressive
Strength
(psi)
Thermal
Resistance
(RSI/25.4 mm)
Thermal
Resistance
(R/inch)
IKO Industries Ltd. Protectobase 180 12.4 0.49 914 x 2440 36 x 96 N/P N/P N/P N/P
IKO Industries Ltd. Protectobase 95 12.4 0.49 914 x 2440 36 x 96 N/P N/P N/P N/P
IKO Industries Ltd. ShieldBase 180 14.7 0.58 914 x 2440 36 x 96 N/P N/P N/P N/P
Soprema Inc. 2-1 SopraSmart Rock 27.6, 40.3 1.09, 1.59 914 x 4880 36 x 192 85, 190 (10, 25%) 12, 28 (10, 25%) 0.7 4
Soprema Inc. 3-1 SopraSmart Rock 78.2 3-3/32 914 x 2440 36 x 96 75 11 0.7 4
Soprema Inc. 2-1 SopraSmart Board 5.4, 7.0 7/32, 9/32 914 x 2440 36 x 96 N/P N/P N/P N/P
Soprema Inc. 2-1 SopraSmart Board ISO HD 14.9 0.6 914 x 2440, 914 x 4880 36 x 96, 36 x 192 550 - 759 80 - 110 0.44 2.5
Soprema Inc. 2-1 SopraSmart ISO HD HP Sanded 15.2 0.6 914 x 2440 36 x 96 550 - 759 80 - 110 0.44 2.5

Mineral Fibre Overlays

Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program
Manufacturer Product Name Thickness
(mm)
Thickness
(in.)
Dimensions
(mm)
Dimensions
(in.)
Compressive
Strength
(kPa)
Compressive
Strength
(psi)
Thermal
Resistance
(RSI/25.4 mm)
Thermal
Resistance
(R/inch)
Soprema Inc. Soprarock MD 25 1 1220 x 1220 48 x 48 84 12.1 0.62 3.5
Soprema Inc. Soprarock MD Plus 25 1 1220 x 1220 48 x 48 84 12.1 0.62 3.5

Fibreboard and Membrane-laminated Fibreboard Overlays

Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program
Manufacturer Product Name Thickness
(mm)
Thickness
(in.)
Dimensions
(mm)
Dimensions
(in.)
Compressive
Strength
(kPa)
Compressive
Strength
(psi)
Thermal
Resistance
(RSI/25.4 mm)
Thermal
Resistance
(R/inch)
IKO Industries Ltd. Asphalt Fibreboard - - - - -
MSL Securtorch 12.5 1/2 1220 x 1220 48 x 48 - - 0.27 1.5
MSL Asphalt Coated (6 sides) - - - - -
MSL Asphalt and Wax Impregnated Fibreboard - - - - -
MSL Asphalt and Wax Impregnated HD - - - - -
MSL Securpan (asphalt coated) - - - - -
Posi-Slope Western MF (Protect Board Composite) - 600 x 1200, 900 x 1200 24 x 48, 36 x 48 - - 4
Roofmart Pacific Ltd. Roofcraft 95 Base FR 14 9/16 900 x 2600 36 x 102 - - 0.55 3.1
Roofmart Pacific Ltd. Roofcraft 180 Base FR 14 9/16 902 x 2600 36 x 102 - - 0.55 3.1
Soprema Inc. 2-1 SopraSmart FB - 910 x 2440 36 x 96 235 34 0.53 3

© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.