Difference between revisions of "Roofs - Insulation Overlays"
Difference between revisions of "Roofs - Insulation Overlays"
(10 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
+ | {{Template:RPM Info}} | ||
+ | |||
+ | __NONUMBEREDHEADINGS__ | ||
+ | |||
+ | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
+ | <div class="row"> | ||
+ | |||
+ | <div class="col-md-3" style="float:right;" id="tocDiv"> | ||
+ | <div class="noautonum">__TOC__</div> | ||
+ | </div> <!-- tocDiv --> | ||
+ | |||
+ | <div class="col-md-9" id="mainBodyDiv"> | ||
+ | |||
+ | <big><big>Division C - Accepted Materials</big></big> | ||
+ | <hr> | ||
+ | <big><big><big><big><big>Roofs: Insulation Overlays</big></big></big></big></big><br> | ||
+ | |||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
Line 19: | Line 36: | ||
* the solvents and adhesives used for flexible membranes may adversely affect the insulation. | * the solvents and adhesives used for flexible membranes may adversely affect the insulation. | ||
<br> | <br> | ||
− | + | ====Asphaltic Overlays==== | |
{{Template:Materials - Insulation Overlay (Asphaltic Board)}} | {{Template:Materials - Insulation Overlay (Asphaltic Board)}} | ||
− | + | ====Fibreglass-faced Silicon-treated Gypsum Core Overlays==== | |
{{Template:Materials - Insulation Overlay (Moisture-resistant Gypsum Core Boards)}} | {{Template:Materials - Insulation Overlay (Moisture-resistant Gypsum Core Boards)}} | ||
− | + | ====High-density Insulation Overlays==== | |
{{Template:Materials - Insulation Overlay (High-density)}} | {{Template:Materials - Insulation Overlay (High-density)}} | ||
− | + | ====Membrane-laminated Overlays==== | |
− | {{Template:Materials - Insulation Overlay ( | + | {{Template:Materials - Insulation Overlay (Membrane-laminated)}} |
− | + | ====Mineral Fibre Overlays==== | |
{{Template:Materials - Insulation Overlay (Mineral Fibre)}} | {{Template:Materials - Insulation Overlay (Mineral Fibre)}} | ||
− | + | ====Fibreboard and Membrane-laminated Fibreboard Overlays==== | |
− | {{Template:Materials - Insulation Overlay (Fibreboard | + | {{Template:Materials - Insulation Overlay (Fibreboard and Membrane-laminated Fibreboard)}} |
+ | </div> | ||
+ | <div class="col-md-12"> | ||
<hr> | <hr> | ||
− | + | [[Main Page | <i class="fa fa-home fa"></i> Home]] | |
− | [[ | + | </div> |
− | + | {{Tempate:RPM Page Footer with Copyright and Current Date}} | |
− | |||
− |
Latest revision as of 18:08, 16 June 2023
Division C - Accepted Materials
Roofs: Insulation Overlays
Accepted Materials for a RoofStar Guarantee
The tables and products shown below provide basic material data and links to more information about the materials, including manufacturers' published Technical Data sheets, but this information is not intended for use as a comparison of material performance or quality. It is the sole responsibility of the Design Authority to assess the performance capability and material suitability for specific design requirements. The materials listed are those which have been accepted by the RoofStar Guarantee Program (RCABC Guarantee Corp., or RGC) for use in a roof or grade-level waterproofing system that will qualify for a RoofStar Guarantee. The acceptance of these materials by the RGC (RoofStar Guarantee Program) in no way reflects on the quality or performance of other materials not listed. The materials and guideline specifications are listed under the name of the manufacturer and/or supplier of the primary membrane material, with the exception of BUR membranes for which the reader will find RoofStar Guarantee Program guidelines on traditional built-up roofing systems (BUR) incorporating organic and glass felt primary membranes. |
Insulation overlays are used to separate the roof membrane from the primary insulation, usually for one of two reasons:
- to prevent the insulation from affecting the performance of the roof membrane
- to prevent the roof membrane and / or the method of application from affecting the insulation
The insulation can affect the performance of the roof membrane in the following ways:
- the insulation may be incompatible with the membrane, resulting in a loss of physical properties
- different coefficients of thermal expansion may result in membrane splits / cracks.
The roof membrane and / or the method of application can affect the insulation in the following ways:
- the insulation may not be capable of withstanding asphalt application temperatures and may “burn-out”
- some insulations will not accommodate direct torch-applied membranes
- insulations that are too “soft” may result in delamination or damage to the membrane or insulation when exposed to heavy loads or traffic
- the solvents and adhesives used for flexible membranes may adversely affect the insulation.
Asphaltic Overlays
Manufacturer | Product Name | Thickness (mm) |
Thickness (in.) |
Dimensions (mm) |
Dimensions (in.) |
Compressive Strength (kPa) |
Compressive Strength (psi) |
Thermal Resistance (RSI/25.4 mm) |
Thermal Resistance (R/inch) |
---|---|---|---|---|---|---|---|---|---|
Hal Industries Inc. | Perma-Board | 4.5 | 3/16 | 1000 x 2000 | 39 x 66 | - | - | - | - |
IKO Industries Ltd. | Protecto Board | 4.5, 6.4, 12.7 | 3/16, 1/4, 1/2 | 1220 x 1520, 1220 x 2440 | 48 x 60, 48 x 96 | - | - | - | - |
IKO Industries Ltd. | Protectobase 95 | 4.5 | 3/16 | - | - | - | - | - | - |
IKO Industries Ltd. | Protectobase 180 | 4.5 | 3/16 | 915 x 2400 | 36 x 96 | - | - | - | - |
Polyglass USA, Inc. | Polyboard E | 4.5, 6 | 3/16, 1/4 | 1220 x 1520 | 48 x 60, 48 x 96 | - | - | - | - |
Polyglass USA, Inc. | Polyboard W | 4.5 | 3/16 | 1000 x 2000 | 40 x 80 | - | - | - | - |
Soprema Inc. | Sopraboard | 4.5, 6.3 | 3/16, 1/4 | 1220 x 1520, 1220 x 2400 | 48 x 60, 48 x 96 | - | - | - | - |
Fibreglass-faced Silicon-treated Gypsum Core Overlays
Manufacturer | Product Name | Thickness (mm) |
Thickness (in.) |
Dimensions (mm) |
Dimensions (in.) |
Compressive Strength (kPa) |
Compressive Strength (psi) |
Thermal Resistance (RSI/25.4 mm) |
Thermal Resistance (R/inch) |
---|---|---|---|---|---|---|---|---|---|
Georgia-Pacific Canada Ltd. | DensDeck® Roofboard | 6.4, 12.7, 15.9 | 1/4, 1/2, 5/8 | 6.4, 12.7, 15.9 | 4 x 8 | 3447 - 6205 | 500 - 900 | - | 0.56 |
Georgia-Pacific Canada Ltd. | DensDeck® Prime with EONIC Roof Board | 6.4, 12.7, 15.9 | 1/4, 1/2, 5/8 | 6.4, 12.7, 15.9 | 4 x 8 | 3447 - 6205 | 500 - 900 | - | 0.56 |
USG (CGC) SecureRock | Securerock Gypsum Fibre Roof Board | - | - | - | - | - | - | - | - |
USG (CGC) SecureRock | Securerock Glass-Mat Roof Board | - | - | - | - | - | - | - | - |
High-density Insulation Overlays
Manufacturer | Product Name | Thickness (mm) |
Thickness (in.) |
Dimensions (mm) |
Dimensions (in.) |
Compressive Strength (kPa) |
Compressive Strength (psi) |
Thermal Resistance (RSI/25.4 mm) |
Thermal Resistance (R/inch) |
---|---|---|---|---|---|---|---|---|---|
Carlisle Syntec Systems Canada | SecurShield HD Plus | 12.5 | 1/2 | 1220 x 2440 | 48 x 96 | 690 | 100 | - | 2.5 |
Elevate (fomerly Firestone) | ISOGARD HD (Grade 1, 2) | 12.5 | 1/2 | 1220 x 1220, 1220 x 2440 | 48 x 48, 48 x 96 | ≥ 551, ≥ 827 | ≥ 80, ≥ 120 | 0.44 | 2.5 |
Hunter Panels | H-Shield HD | 12.5 | 1/2 | 1220 x 2440 | 48 x 96 | 620 | 90 | 0.44 | 2.5 |
IKO Industries Ltd. | IKOTherm Covershield | 12.5 | 1/2 | 1220 x 2440 | 48 x 96 | 620 | 90 | 0.44 | 2.5 |
Johns Manville Corporation | Retrofit Board | 12.5 | 1/2 | 610 x 1220, 1220 x 1220, 1220 x 2440 | 24 x 48, 48 x 48, 48 x 96 | 255 | 37 | 0.46 | 2.64 |
Johns Manville Corporation | Invinsa Roof Board | 6.3 | 1/4 | 1220 x 1220, 1220 x 2440 | 48 x 48, 48 x 96 | 1034 | 150 | - | 1 |
Siplast, Inc. | Paratherm HD | 12.5 | 1/2 | 1220 x 1220, 1220 x 2440 | 48 x 48, 48 x 96 | 552 | 80 | 0.44 | 2.5 |
Siplast, Inc. | Paratherm W HD | 12.5 | 1/2 | 1220 x 1220, 1220 x 2440 | 48 x 48, 48 x 96 | 552 | 80 | 0.44 | 2.5 |
Soprema Inc. | Sopra-Iso Plus HD | 12.5 | 1/2 | 1220 x 1220, 1220 x 2440 | 48 x 48, 48 x 96 | 689 | 100 | 0.44 | 2.5 |
Membrane-laminated Overlays
Manufacturer | Product Name | Thickness (mm) |
Thickness (in.) |
Dimensions (mm) |
Dimensions (in.) |
Compressive Strength (kPa) |
Compressive Strength (psi) |
Thermal Resistance (RSI/25.4 mm) |
Thermal Resistance (R/inch) |
---|---|---|---|---|---|---|---|---|---|
IKO Industries Ltd. | Protectobase 180 | 12.4 | 0.49 | 914 x 2440 | 36 x 96 | N/P | N/P | N/P | N/P |
IKO Industries Ltd. | Protectobase 95 | 12.4 | 0.49 | 914 x 2440 | 36 x 96 | N/P | N/P | N/P | N/P |
IKO Industries Ltd. | ShieldBase 180 | 14.7 | 0.58 | 914 x 2440 | 36 x 96 | N/P | N/P | N/P | N/P |
Soprema Inc. | 2-1 SopraSmart Rock | 27.6, 40.3 | 1.09, 1.59 | 914 x 4880 | 36 x 192 | 85, 190 (10, 25%) | 12, 28 (10, 25%) | 0.7 | 4 |
Soprema Inc. | 3-1 SopraSmart Rock | 78.2 | 3-3/32 | 914 x 2440 | 36 x 96 | 75 | 11 | 0.7 | 4 |
Soprema Inc. | 2-1 SopraSmart Board | 5.4, 7.0 | 7/32, 9/32 | 914 x 2440 | 36 x 96 | N/P | N/P | N/P | N/P |
Soprema Inc. | 2-1 SopraSmart Board ISO HD | 14.9 | 0.6 | 914 x 2440, 914 x 4880 | 36 x 96, 36 x 192 | 550 - 759 | 80 - 110 | 0.44 | 2.5 |
Soprema Inc. | 2-1 SopraSmart ISO HD HP Sanded | 15.2 | 0.6 | 914 x 2440 | 36 x 96 | 550 - 759 | 80 - 110 | 0.44 | 2.5 |
Mineral Fibre Overlays
Manufacturer | Product Name | Thickness (mm) |
Thickness (in.) |
Dimensions (mm) |
Dimensions (in.) |
Compressive Strength (kPa) |
Compressive Strength (psi) |
Thermal Resistance (RSI/25.4 mm) |
Thermal Resistance (R/inch) |
---|---|---|---|---|---|---|---|---|---|
Soprema Inc. | Soprarock MD | 25 | 1 | 1220 x 1220 | 48 x 48 | 84 | 12.1 | 0.62 | 3.5 |
Soprema Inc. | Soprarock MD Plus | 25 | 1 | 1220 x 1220 | 48 x 48 | 84 | 12.1 | 0.62 | 3.5 |
Fibreboard and Membrane-laminated Fibreboard Overlays
Manufacturer | Product Name | Thickness (mm) |
Thickness (in.) |
Dimensions (mm) |
Dimensions (in.) |
Compressive Strength (kPa) |
Compressive Strength (psi) |
Thermal Resistance (RSI/25.4 mm) |
Thermal Resistance (R/inch) |
---|---|---|---|---|---|---|---|---|---|
IKO Industries Ltd. | Asphalt Fibreboard | ‒ | - | - | - | - | - | ‒ | ‒ |
MSL | Securtorch | 12.5 | 1/2 | 1220 x 1220 | 48 x 48 | - | - | 0.27 | 1.5 |
MSL | Asphalt Coated (6 sides) | ‒ | - | - | - | - | - | ‒ | ‒ |
MSL | Asphalt and Wax Impregnated Fibreboard | ‒ | - | - | - | - | - | ‒ | ‒ |
MSL | Asphalt and Wax Impregnated HD | ‒ | - | - | - | - | - | ‒ | ‒ |
MSL | Securpan (asphalt coated) | ‒ | - | - | - | - | - | ‒ | ‒ |
Posi-Slope Western | MF (Protect Board Composite) | ‒ | - | 600 x 1200, 900 x 1200 | 24 x 48, 36 x 48 | - | - | 4 | ‒ |
Roofmart Pacific Ltd. | Roofcraft 95 Base FR | 14 | 9/16 | 900 x 2600 | 36 x 102 | - | - | 0.55 | 3.1 |
Roofmart Pacific Ltd. | Roofcraft 180 Base FR | 14 | 9/16 | 902 x 2600 | 36 x 102 | - | - | 0.55 | 3.1 |
Soprema Inc. | 2-1 SopraSmart FB | ‒ | - | 910 x 2440 | 36 x 96 | 235 | 34 | 0.53 | 3 |
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.