Search results

Jump to: navigation, search

Search results

Page title matches

Page text matches

  • = D1. SBS (New Version) = ...enerally compatible with asphalt products, and are therefore useful for re-roofing.
    0 members (0 subcategories, 0 files) - 16:30, 23 June 2015
  • ...ey are generally compatible with asphalt products and may be useful for re-roofing projects). ==SBS==
    22 KB (3,281 words) - 21:46, 17 July 2017
  • ::'''''Uninsulated Systems''''' - typically insulated below the ''roof deck''. ...referred to as ''Compact Roofs'', these are insulated ''beneath'' the roof membrane.
    30 KB (4,336 words) - 21:13, 18 August 2021
  • ...he roofing assembly, be it membrane, ballast or growing medium (soil). All membrane flashing (stripping) terminating on a vertical surface must be mechanically ...assemblies tested to and compliant with [[RoofStar Guarantee Standards for SBS Modified Bitumen Roof Assemblies#SBS4| '''CSA A123.21''']] (latest edition)
    14 KB (2,091 words) - 22:59, 9 November 2018
  • Only RoofStar-accepted insulation materials, specifically listed by membrane manufacturers in this Manual as acceptable for use with their modified bitu ...for vertical applications.Where deck nailing strips are required to secure roofing nailing or insulation nailing strips (e.g. in concrete decks), deck nailing
    14 KB (2,160 words) - 15:21, 29 September 2016
  • || Carlisle Syntec Systems Canada || Carlisle EPDM-TPO-PVC Cav Grip Adhesive-Primer || style="text-ali || Carlisle Syntec Systems Canada || Carlisle EPDM-TPO-PVC CCW 702 Membrane Adhesive || style="text-align:center;"| '''TDS''' || style="text-align:cen
    15 KB (1,915 words) - 17:59, 14 September 2017
  • ...ing of polyester, fibreglass or a combination of both reinforcement types. SBS modified bituminous membranes are available in varied thicknesses with spec :Bituminous and modified bituminous flexible membrane systems are composite sheet membranes which are thermoplastic in nature but display
    16 KB (1,620 words) - 17:29, 26 February 2018
  • <big>Waterproofing Roof Systems: Thermosplastic Membranes</big><br> <big><big><big><big><big><big>Standard for PVC Membrane Roof Systems</big></big></big></big></big></big>
    416 KB (56,532 words) - 22:23, 5 April 2024
  • <big>Waterproofing Roof Systems: Thermoset Membranes</big><br> <big><big><big><big><big><big>Standard for EPDM Membrane Roof Systems</big></big></big></big></big></big>
    424 KB (57,418 words) - 22:20, 5 April 2024
  • <big>Waterproofing Roof Systems: Thermosplastic Membranes</big><br> <big><big><big><big><big><big>Standard for TPO Membrane Roof Systems</big></big></big></big></big></big>
    421 KB (57,062 words) - 22:20, 5 April 2024
  • <big>Waterproofing Roof Systems: Liquid Membranes</big><br> ...<big><big><big><big>Standard for Hot Fluid-applied Rubberized Asphalt Roof Systems</big></big></big></big></big></big>
    296 KB (41,811 words) - 22:23, 5 April 2024
  • <big><big><big><big><big>SBS | Open-wall Scupper Drain ([[SBS_Roof_Systems_Standard#11.3.3.7._Scuppers_a <div class="panel-heading"><big>'''SBS Details'''</big></div>
    3 KB (440 words) - 18:14, 27 October 2023
  • <big><big><big><big><big>SBS | Through-wall Scupper Drain ([[SBS_Roof_Systems_Standard#11.3.3.7._Scupper <div class="panel-heading"><big>'''SBS Details'''</big></div>
    3 KB (420 words) - 18:15, 27 October 2023
  • ...severe. Large, highly insulated roof areas impose greater stresses on the membrane. Formerly expensive synthetic materials have become more cost competitive a ...itional products and methods. This may prove especially advantageous in re-roofing over surfaces contaminated with bitumen.
    23 KB (3,307 words) - 15:57, 9 September 2021
  • :The ability of a membrane to resist being worn away by contact with a moving abrasive surface, such a ...g materials and components should be ensured through consultation with the membrane supplier. Failure to do so could result in the degradation of these materia
    76 KB (11,565 words) - 18:09, 26 January 2024
  • The roofing assembly / material information published in the RCABC '''''Roofing Practices Manual''''' and offered below does NOT represent a complete set o ...ing system specially designed to work with a variety of bituminous roofing systems to ensure the weatherproofing of a wide range of details. It is a liquid ap
    6 KB (899 words) - 21:37, 13 November 2020
  • <big><big><big><big><big>SBS | Plumbing Vent (Conventional Roof System) ([[SBS_Roof_Systems_Standard#12. <div class="panel-heading"><big>'''SBS Details'''</big></div>
    3 KB (418 words) - 18:15, 27 October 2023
  • ...eaves, walls, vents, etc. must be sealed to prevent moisture from entering roofing or between plies of stripping. ...cap sheet is an SBS modified bitumen sheet, then the base sheet must be an SBS modified bitumen sheet. Oxidized asphalt sheets will be considered as under
    23 KB (1,531 words) - 22:55, 9 November 2018
  • ...rsion in water with the exception of protected and modified protected roof systems. ...The metal flashing is not a waterproofing membrane, therefore the roofing membrane should be continuous under the metal.</p>
    12 KB (1,696 words) - 22:01, 7 March 2018
  • <span class="principles">Use only membrane manufacturer’s approved proprietary urethane based structural sealants to ...than standard flashings must have site formed non-bituminous flexible roof membrane storm collars sealed with compatible sealants and stainless steel clamps. {
    12 KB (1,802 words) - 15:50, 30 March 2017
  • :#Only RoofStar-accepted insulation, specifically listed by membrane manufacturers in the RPM as acceptable for use with their modified bitumino ...''Accepted Roof Insulation products'''] for '''RoofStar Guaranteed''' roof systems.
    18 KB (2,588 words) - 17:28, 13 March 2018
  • ...ntact with asphaltic membranes of any type shall be primed both sides with membrane manufacturers approved primer and embedded in a trowel coating of compatibl ...e corners shall be closed and soldered. <span class="principles">Use only membrane manufacturer’s approved proprietary urethane based structural sealants to
    14 KB (1,967 words) - 22:58, 9 November 2018
  • <div id="METALBASE-SBS"></div> ...rsion in water with the exception of protected and modified protected roof systems.
    10 KB (1,482 words) - 22:00, 7 March 2018
  • ==== [[Eave Protection & Underlayment (Architectural Metal Roofing)]] ==== ==== [[Flexible Membrane Roofing Systems: SBS|SBS Membranes]] ====
    2 KB (254 words) - 17:18, 6 June 2016
  • ==== [[Eave Protection & Underlayment (Architectural Metal Roofing)]] ==== ==== [[Flexible Membrane Roofing Systems: SBS|SBS Membranes]] ====
    2 KB (254 words) - 17:18, 6 June 2016
  • <div class="panel-heading">Welcome to the '''RCABC Roofing Practices Manual'''</div> The RPM Online is the official version of the Roofing Practices Manual and supersedes all other printed versions which may be in
    7 KB (990 words) - 20:54, 2 August 2016
  • <big><big><big><big><big>Standard for Grade-level Waterproofing Systems</big></big></big></big></big> ...spaces, subsequently this makes <b><i>waterproofing and protected roofing systems,</i></b> not dampproofing, the only reliable options to prevent the passage
    117 KB (13,071 words) - 18:36, 5 April 2024
  • <i>Product Group:</i> <b>SBS MODIFIED BITUMINOUS MEMBRANES</b> ...membranes, and the High Performance Composite systems, all tough, flexible SBS polymer modified bitumen prefabricated sheets, appropriately reinforced and
    14 KB (2,024 words) - 18:30, 9 November 2016
  • <i>Product Group:</i> <b>SBS MODIFIED BITUMINOUS MEMBRANES</b> ...roofing systems are the TORCHFLEX and MODIFLEX membranes: tough, flexible, SBS polymer modified bitumen prefabricated sheets, appropriately reinforced and
    11 KB (1,543 words) - 18:21, 9 November 2016
  • Product Group: <b>SBS MODIFIED BITUMINOUS WATERPROOFING MEMBRANES</b> ...roofing systems are the TORCHFLEX and MODIFLEX membranes: tough, flexible, SBS polymer modified bitumen prefabricated sheets, appropriately reinforced and
    8 KB (1,205 words) - 18:26, 9 November 2016
  • <i>Product Group:</i> <b>BUILT-UP ROOFING SYSTEMS EXPOSED MEMBRANES, INSULATED </b> ...S membranes, see the [[GAF SBS Membrane Installation Guidelines|'''GAF SBS Membrane Installation Guidelines''']] elsewhere in this Manual.
    25 KB (3,685 words) - 16:52, 4 November 2016
  • <i>Product Group:</i> <b>SBS MODIFIED PROPRIETARY BUR SYSTEM</b> ...land Company is a leading manufacturer and distributor of high-performance roofing and flooring solutions for commercial, industrial, and public properties. W
    22 KB (3,005 words) - 17:17, 4 November 2016
  • Product Group: <b>SBS MODIFIED BITUMINOUS WATERPROOFING MEMBRANES</b> ...membranes and the high performance composite systems, all tough, flexible SBS polymer modified bitumen prefabricated sheets, appropriately reinforced an
    7 KB (1,060 words) - 18:29, 9 November 2016
  • ...eaves, walls, vents, etc. must be sealed to prevent moisture from entering roofing or between plies of stripping. ...2 (1" in 12"), back-nail mopped sheet at 600 mm (2' 0") using large-headed roofing nails. On insulated roofs, install nailing strips to facilitate back-nailin
    14 KB (2,005 words) - 21:35, 25 January 2017
  • ...he roofing assembly, be it membrane, ballast or growing medium (soil). All membrane flashing (stripping) terminating on a vertical surface must be mechanically ...s tested to and compliant with [[RoofStar Guarantee Standards for SBS Roof Systems#SBS4| '''CSA A123.21''']] (latest edition), and include a calculation for t
    12 KB (1,724 words) - 21:46, 16 February 2018
  • ...ntact with asphaltic membranes of any type shall be primed both sides with membrane manufacturers approved primer and embedded in a trowel coating of compatibl ...e corners shall be closed and soldered. <span class="principles">Use only membrane manufacturer’s approved proprietary urethane based structural sealants to
    14 KB (1,966 words) - 15:51, 30 March 2017
  • ...rsion in water with the exception of protected and modified protected roof systems. ...tripping plies shall be two overlapping plies of a minimum 2 mm reinforced SBS modified bitumen base sheet or two overlapping plies of a minimum 180 g / m
    10 KB (1,568 words) - 22:02, 7 March 2018
  • :#Only RoofStar-accepted insulation, specifically listed by membrane manufacturers in the RPM as acceptable for use with their modified bitumino ...epted Roof Insulation products''']] for '''''RoofStar Guaranteed''''' roof systems.
    18 KB (2,573 words) - 17:29, 13 March 2018
  • ...is applied" (adapted from ''ASTM D1079-18 Standard Terminology Relating to Roofing and Waterproofing'')|| 2021-June-30 }}. ...to render the deck surface continuous or suitable for the installation of roofing materials|| 2021-June-30 }}.
    27 KB (3,843 words) - 16:12, 15 October 2021
  • :<big><big>'''Roof Waterproofing Systems'''</big></big> ...ials - SBS Modified Bitumen Membrane Systems|SBS Modified Bitumen Membrane Systems]]</big>
    2 KB (224 words) - 21:55, 3 September 2021
  • <big><big><big><big><big>Standard for Grade-level Waterproofing Systems</big></big></big></big></big> ...spaces, subsequently this makes <b><i>waterproofing and protected roofing systems,</i></b> not dampproofing, the only reliable options to prevent the passage
    117 KB (13,068 words) - 18:35, 5 April 2024
  • The roofing assembly / material information published in the RCABC '''''Roofing Practices Manual''''' and offered below does NOT represent a complete set o ;Accepted for application in: Waterproofing Systems (roofs)
    1 KB (207 words) - 15:22, 27 October 2020
  • The roofing assembly / material information published in the RCABC '''''Roofing Practices Manual''''' and offered below does NOT represent a complete set o ;Accepted for application in: Waterproofing Systems (roofs)
    2 KB (217 words) - 19:46, 12 May 2023
  • ...is applied" (adapted from ''ASTM D1079-18 Standard Terminology Relating to Roofing and Waterproofing'')|| 2021-June-30 }}. ...to render the deck surface continuous or suitable for the installation of roofing materials|| 2021-June-30 }}.
    25 KB (3,617 words) - 14:49, 23 December 2021
  • ...brane flashing must be in keeping with the Standards in '''11.3.3.3 Liquid Membrane Flashing''' || 2020-October-22 }}. <li>With the exception of ''overflows'', ''scupper drains'' and membrane gutters, roof drains and penetration flashings for new construction ''proje
    56 KB (8,120 words) - 20:44, 19 May 2022
  • ...brane flashing must be in keeping with the Standards in '''11.3.3.3 Liquid Membrane Flashing'''. <li>{{hilite | With the exception of ''overflows'', ''scupper drains'' and membrane gutters, roof drains and penetration flashings for new construction ''proje
    45 KB (6,830 words) - 19:36, 11 March 2022
  • ...brane flashing must be in keeping with the Standards in '''11.3.3.3 Liquid Membrane Flashing'''. <li>{{hilite | With the exception of ''overflows'', ''scupper drains'' and membrane gutters, roof drains and penetration flashings for new construction ''proje
    45 KB (6,811 words) - 20:28, 9 July 2021
  • ...brane flashing must be in keeping with the Standards in '''11.3.3.3 Liquid Membrane Flashing''' || 2020-October-22 }}. <li>With the exception of ''overflows'', ''scupper drains'' and membrane gutters, roof drains and penetration flashings for new construction ''proje
    56 KB (8,117 words) - 15:53, 27 August 2021
  • ...ig><big><big><big>Notes to Standard for SBS-modified Bitumen Membrane Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    61 KB (8,812 words) - 18:01, 2 April 2024
  • ...he accepted membrane manufacturer's written submissions. In all cases, the membrane manufacturer should be contacted for further recommendations and details. In order to formulate materials to satisfy the requirements of a roof membrane, the manufacturer must ensure:
    33 KB (4,674 words) - 16:01, 9 September 2021
  • <big>Water-shedding Roof Systems: Metals</big><br> <big><big><big><big><big>Standard for Architectural Sheet Metal (ASM) Roof Systems</big></big></big></big></big>
    260 KB (36,048 words) - 21:32, 5 April 2024
  • <big>Waterproofing Roof Systems: Flexible Membranes (Polymer-modified Bituminous)</big><br> <big><big><big><big><big><big>Standard for SBS-modified Bitumen Membrane Roof Systems</big></big></big></big></big></big>
    465 KB (62,115 words) - 14:08, 16 May 2024
  • <big>Waterproofing Roof Systems: Thermoset Membranes</big><br> <big><big><big><big><big><big>Standard for EPDM Membrane Roof Systems</big></big></big></big></big></big>
    423 KB (57,312 words) - 21:21, 5 April 2024
  • <big>Waterproofing Roof Systems: Thermosplastic Membranes</big><br> <big><big><big><big><big><big>Standard for TPO Membrane Roof Systems</big></big></big></big></big></big>
    420 KB (56,956 words) - 21:23, 5 April 2024
  • <big>Waterproofing Roof Systems: Thermosplastic Membranes</big><br> <big><big><big><big><big><big>Standard for PVC Membrane Roof Systems</big></big></big></big></big></big>
    415 KB (56,426 words) - 21:31, 5 April 2024
  • <big>Water-shedding Roof Systems: Bituminous</big><br> <big><big><big><big><big>Standard for Asphalt Shingle Roof Systems</big></big></big></big></big>
    235 KB (33,160 words) - 21:33, 5 April 2024
  • <big>Waterproofing Roof Systems: Liquid Membranes</big><br> ...<big><big><big><big>Standard for Hot Fluid-applied Rubberized Asphalt Roof Systems</big></big></big></big></big></big>
    294 KB (41,687 words) - 21:32, 5 April 2024
  • <big>Waterproofing Roof Systems: Flexible Membranes (Polymer-modified Bituminous)</big><br> <big><big><big><big><big><big>Standard for SBS-modified Bitumen Membrane Roof Systems</big></big></big></big></big></big>
    466 KB (62,224 words) - 14:08, 16 May 2024
  • ...ig><big><big><big>Notes to Standard for SBS-modified Bitumen Membrane Roof Systems</big></big></big></big></big> :<big>'''A-1.1.3.1.'''</big> ('''Permitted Roof Systems''')
    61 KB (8,848 words) - 18:15, 2 April 2024
  • ...brane flashing must be in keeping with the Standards in '''11.3.3.3 Liquid Membrane Flashing'''. <li>{{hilite | With the exception of ''overflows'', ''scupper drains'' and membrane gutters, roof drains and penetration flashings for new construction ''proje
    45 KB (6,830 words) - 19:36, 11 March 2022
  • ...brane flashing must be in keeping with the Standards in '''11.3.3.3 Liquid Membrane Flashing'''. <li>{{hilite | With the exception of ''overflows'', ''scupper drains'' and membrane gutters, roof drains and penetration flashings for new construction ''proje
    45 KB (6,830 words) - 19:37, 11 March 2022
  • <big>Water-shedding Roof Systems: Metals</big><br> <big><big><big><big><big>Standard for Architectural Sheet Metal (ASM) Roof Systems</big></big></big></big></big>
    261 KB (36,152 words) - 22:24, 5 April 2024
  • <big>Water-shedding Roof Systems: Bituminous</big><br> <big><big><big><big><big>Standard for Asphalt Shingle Roof Systems</big></big></big></big></big>
    236 KB (33,264 words) - 22:24, 5 April 2024