Search results
Search results
Create the page "Insulation" on this wiki! See also the search results found.
Page title matches
- #REDIRECT [[Insulation Joints and Overlays]]44 bytes (5 words) - 15:50, 23 October 2018
- #REDIRECT [[Insulation Joints and Overlay]]43 bytes (5 words) - 18:19, 25 November 2015
- <big><big><big><big><big>Roofs: Insulation</big></big></big></big></big> ===Heat-resistant Insulation===3 KB (377 words) - 21:49, 7 September 2021
- <big><big><big><big><big>Insulation Joints and Overlays</big></big></big></big></big> Insulation overlays are used to separate the roof membrane from the primary insulation, usually for one of two reasons:4 KB (532 words) - 15:44, 9 September 2021
- <big><big><big><big><big>Roofs: Insulation Joint Tape</big></big></big></big></big> <big><big>[[Insulation Joints and Overlay|Insulation Joint Tape]]</big></big>960 bytes (129 words) - 21:48, 7 September 2021
- ...g Roof System (typically ASM) to separate the roof panels from the primary insulation, and to provide a flat, firm surface for the installation of panel clips (u For more information about the use of insulation overlays in a Water-shedding Roof System, consult the specific roof system1 KB (185 words) - 14:15, 27 July 2021
- ===Heat-resistant Insulation=== {{Template:Materials - Insulation (Polyisocyanurate)}}2 KB (251 words) - 14:13, 27 July 2021
- {{Template:Materials - Insulation (XPS)}}485 bytes (56 words) - 14:10, 27 July 2021
- <big><big><big><big><big>Roofs: Insulation Overlays</big></big></big></big></big><br> Insulation overlays are used to separate the roof membrane from the primary insulation, usually for one of two reasons:3 KB (334 words) - 18:08, 16 June 2023
Page text matches
- #REDIRECT [[Insulation Joints and Overlays]]44 bytes (5 words) - 15:50, 23 October 2018
- ...C) test and classify roof assemblies (includes roof deck, vapour retarder, insulation, membrane, etc.), roof components, and (specifically) roof-covering materia5 KB (808 words) - 16:06, 9 September 2021
- #REDIRECT [[Insulation Joints and Overlay]]43 bytes (5 words) - 18:19, 25 November 2015
- ...ts and Overlay|<i class="fa fa-hand-o-right" aria-hidden="true"></i> <big>Insulation Joints and Overlay Boards</big>]]2 KB (290 words) - 20:13, 22 August 2016
- ...heir protective surfacing will allow many minor anomalies, such as deck or insulation unevenness, to readily telescope through to the roof surface. Over time, d22 KB (3,281 words) - 21:46, 17 July 2017
- ...tyrene insulation board can be installed in thicknesses necessary for high insulation values and in a stair stepped fashion, facilitating a positive slope to dra :Poured 25 mm (1") for NVS and 50 mm (2") for Insulcel thickness over EPS insulation, these LWIC systems have been engineered for use over non-slotted or slotte3 KB (474 words) - 21:16, 12 February 2019
- ::[[BUR Roof Systems Standard#BURINSULATION |7 INSULATION]] ::[[BUR Roof Systems Standard#BURINSULATIONOVERLAY |8 INSULATION OVERLAY BOARD]]2 KB (209 words) - 21:11, 30 August 2021
- *Insulation (board or panel; tapered) *Insulation overlay board22 KB (3,050 words) - 16:20, 12 December 2023
- * Use a protective base sheet on all wood decks and over ignitable insulation, can strips or other flammable surfaces. ...all ignitable insulation surfaces, edges and over all joints between rigid insulation boards. The base ply provides a protective covering for underlying ignitab14 KB (2,333 words) - 16:39, 9 February 2022
- .../index.php?title=Standard_for_SBS-Modified_Bitumen_Membrane_Systems#PART_7 Insulation]=== :<big><big>Composite Board Insulation</big></big>6 KB (742 words) - 20:36, 27 July 2021
- | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]416 KB (56,532 words) - 22:23, 5 April 2024
- | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]424 KB (57,418 words) - 22:20, 5 April 2024
- | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]421 KB (57,062 words) - 22:20, 5 April 2024
- | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]296 KB (41,811 words) - 22:23, 5 April 2024
- <big><big>'''Secondary Materials: Insulation & Overlays'''</big></big> ...s - Insulation (Waterproofing Systems) | <i class="fa fa-caret-right"></i> Insulation]]</big>13 KB (1,636 words) - 17:02, 5 January 2024
- ...ight, and free of "humps" or depressions. These can counteract any sloped insulation systems installed by the roofing contractor and cause ponding. On new cons ...vel in the roof deck are less than the percentage of slope provided by the insulation. A minimum slope of 1:50 (1/4" in 12") is strongly recommended. The except20 KB (2,969 words) - 16:06, 9 September 2021
- ...he membrane, or as a thermal barrier between the roof deck and combustible insulation.1 KB (198 words) - 15:33, 9 September 2021
- ...testing is specified, testing shall be conducted prior to installation of insulation and roof coverings, and must be performed to ''ASTM D5957''.11 KB (1,608 words) - 22:03, 3 May 2021
- | Part 7 || '''Insulation''' | Part 8 || '''Insulation Overlays''' (Eave protection, Underlayments, and ventilation, in the Standa15 KB (2,132 words) - 19:02, 18 August 2023
- [[File:Low-slope Roof Insulation.jpg|300 px]] ...ctions. As part of the roof assembly, properly designed and installed roof insulation provides the following benefits:23 KB (3,279 words) - 15:42, 9 September 2021
- Refer to the '''Insulation''' or '''Membrane''' Manufacturer's specifications.227 bytes (26 words) - 13:51, 27 July 2021
- ...terproofing membranes, testing shall be conducted prior to installation of insulation and overburdens and be performed to ASTM D5957 - 98.2 KB (249 words) - 22:45, 9 November 2016
- <big><big><big><big><big>Roofs: Insulation</big></big></big></big></big> ===Heat-resistant Insulation===3 KB (377 words) - 21:49, 7 September 2021
- <big><big><big><big><big>Insulation Joints and Overlays</big></big></big></big></big> Insulation overlays are used to separate the roof membrane from the primary insulation, usually for one of two reasons:4 KB (532 words) - 15:44, 9 September 2021
- ;(6) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua3 KB (360 words) - 18:16, 27 October 2023
- ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in Division C of this ''Manual''.2 KB (262 words) - 18:33, 27 June 2022
- ...[[SBS Roof Systems Standard#PART_7|'''Insulation - XPS''']]: See available insulation products in Division C of this ''Manual''.2 KB (284 words) - 18:34, 27 June 2022
- ...ed. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Division C | Division C]] of this Manual.3 KB (429 words) - 21:34, 27 June 2022
- ...Standard#PART_5|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...ed. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Division C | Division C]] of this Manual.3 KB (367 words) - 21:52, 27 June 2022
- ...s#EPDMSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.3 KB (351 words) - 16:48, 23 October 2017
- ...s#EPDMSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.3 KB (347 words) - 16:48, 23 October 2017
- ...s#EPDMSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.3 KB (332 words) - 16:49, 23 October 2017
- ...s#EPDMSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.3 KB (334 words) - 18:30, 23 October 2017
- <big><big><big><big><big>Roofs: Insulation Joint Tape</big></big></big></big></big> <big><big>[[Insulation Joints and Overlay|Insulation Joint Tape]]</big></big>960 bytes (129 words) - 21:48, 7 September 2021
- ...materials due to thermal and moisture variations. Traditionally, the roof insulation and roofing are secured to the roof deck by means of mechanical fastening, '''''RoofStar Guarantee Standards''''' requires mechanical fastening of the insulation wherever practical. Over concrete and other non-nailable decks, or where me7 KB (999 words) - 15:42, 9 September 2021
- ...tables specified minimum thermal resistance values, depending on where the insulation was installed, but these requirements were not integrated with the design a21 KB (3,118 words) - 16:32, 16 March 2023
- ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(3) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Where required.3 KB (440 words) - 18:14, 27 October 2023
- ;(2) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(3) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Where required.3 KB (420 words) - 18:15, 27 October 2023
- ...existing coal tar pitch roofs. In these cases a separation layer, such as insulation board, is often used to prevent the asphalt system from contacting any trac | Insulation || +204°C (+400°F) to +149°C (+300°F) || 16 Seconds15 KB (2,293 words) - 15:33, 9 September 2021
- ...re the insulation is above the membrane, the gravel is used to protect the insulation from ultraviolet rays, wind uplift, and flotation. For ballast and securem8 KB (1,280 words) - 16:25, 9 September 2021
- ...#8220;conventional” roof assembly the roof membrane is on top of the insulation where it is subject to many life-shortening elements, and it must function ...roduce a problem with vapour trapped within the assembly. This can lead to insulation and roof membrane deterioration and, eventually, roof failure.11 KB (1,624 words) - 16:21, 9 September 2021
- ...h living space condenses in the attic, producing moisture on wood framing, insulation and roofing. || [[File:Roofventcold.gif]] || Proper ventilation allows mois ...all be designed to prevent the entry of rain, snow and insects. || Ceiling insulation shall not be installed in a manner that will restrict free flow of air thou6 KB (911 words) - 15:33, 9 September 2021
- ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual. ...yed (3A: 2- part low rising insulation adhesive, specifically used to bond insulation and cover boards)4 KB (462 words) - 17:01, 23 October 2017
- ...ts. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Division C | Division C]] of this Manual.2 KB (281 words) - 21:53, 27 June 2022
- ...ed. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Division C | Division C]] of this Manual.3 KB (422 words) - 21:33, 27 June 2022
- ...es#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.3 KB (382 words) - 17:02, 23 October 2017
- ...es#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.3 KB (360 words) - 17:01, 23 October 2017
- ...es#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.3 KB (374 words) - 17:02, 23 October 2017
- ...es#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.3 KB (373 words) - 17:02, 23 October 2017
- ...lso Accepted Roof Deck Insulation products by clicking on this [[Roof Deck Insulation|link]]. :{{Template:Insulation (Polyiso)}}146 bytes (19 words) - 17:16, 17 June 2016
- ...g Roof System (typically ASM) to separate the roof panels from the primary insulation, and to provide a flat, firm surface for the installation of panel clips (u For more information about the use of insulation overlays in a Water-shedding Roof System, consult the specific roof system1 KB (185 words) - 14:15, 27 July 2021
- ===Heat-resistant Insulation=== {{Template:Materials - Insulation (Polyisocyanurate)}}2 KB (251 words) - 14:13, 27 July 2021
- {{Template:Materials - Insulation (XPS)}}485 bytes (56 words) - 14:10, 27 July 2021
- ...oof Systems Standard#PART_5|'''Supporting Deck Overlay''']]: Required when insulation is too thin to span flutes of steel decking or when required as thermal bar ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in the[[Division C| Accepted Materials]] Division of this ''Manual4 KB (607 words) - 18:19, 27 October 2023
- ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: Installed in staggered and offset layers, and secured in accordance w ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Subject to the requirements of '''Part 8''' in the '''''RoofS4 KB (630 words) - 18:16, 27 October 2023
- ...oof Systems Standard#PART_5|'''Supporting Deck Overlay''']]: Required when insulation is too thin to span flutes of steel decking or when required as thermal bar ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua3 KB (420 words) - 18:14, 27 October 2023
- ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: Installed in staggered and offset layers (not illustrated), and secur ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Subject to the requirements of '''Part 8''' in the '''''RoofS3 KB (474 words) - 18:18, 27 October 2023
- ;(2) '''Insulation Overlay Protection''': Recommended. ;(5) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMINS |'''Insulation''']]: Installed between ‘Z’ bars or wood battens on 600 mm (242 KB (291 words) - 16:27, 26 April 2019
- ;(3) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Installed with offset side and end joints. ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material (see [http://rpm.rcabc.org/index.php?4 KB (540 words) - 17:25, 28 June 2022
- ;(2) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Offset and stagger layers 300 mm (12"). ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material (see [http://rpm.rcabc.org/index.php?3 KB (432 words) - 19:00, 28 June 2022
- ;(3) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Offset and stagger layers 300 mm (12"). ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material.4 KB (537 words) - 17:35, 17 March 2023
- ;(2) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Offset and stagger layers 300 mm (12"). ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material (see [http://rpm.rcabc.org/index.php?4 KB (530 words) - 20:11, 28 June 2022
- ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels (see [http://rpm.rcabc.org/index.php?title=RoofStar_Guaran3 KB (430 words) - 16:23, 28 June 2022
- ;(4) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Tapered to support gutter membrane, which is tied into underlayment, ...ART_7| '''Upper insulation''']]: Tapered at lower edge to conform to lower insulation slope. All flat panels must be offset and stagger layers 300 mm (12").5 KB (611 words) - 18:17, 12 March 2024
- ...oof system specifications. In addition, approved proprietary underlayment, insulation overlays and metal panel separation sheets must be installed and comply to (2) <b>Ice Dam Protection / Insulation Overlay: </b>For slopes 2:12 to 4:12 use RGC accepted self-adhered modified3 KB (421 words) - 22:51, 21 December 2015
- ...Standard#PART_5|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.3 KB (383 words) - 21:38, 27 June 2022
- ;(5) [[Grade-level Waterproofing Standard#WPINSULATION | '''Insulation''']]: Optional: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, co4 KB (527 words) - 21:15, 7 September 2021
- ;(6) [[Grade-level Waterproofing Standard#WPINSULATION | '''Insulation''']]: Optional: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, co ...]: Synthetic permeable fabric required over extruded, expanded polystyrene insulation overburdened with pavers, growing mediums, sand and gravel beds for unit ma4 KB (527 words) - 21:16, 7 September 2021
- ...oofing Standard#WPDECK | '''Plaza Deck Assembly''']]: Extruded polystyrene insulation and filter mat (optional) over primary waterproofing membrane. Concrete pav5 KB (580 words) - 21:16, 7 September 2021
- ;(3) [[Grade-level Waterproofing Standard#WPINSULATION | '''Insulation''']]: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, compressive ;(B) Supporting Curb: Height varies depending on the insulation thickness and type of waterproofing assembly.4 KB (596 words) - 21:17, 7 September 2021
- ...ng Standard#WPINSULATION | '''Insulation''']]: Type 4 extruded polystyrene insulation ...paver pedestals designed to carry predicted live loads and accepted by the insulation manufacturer.3 KB (413 words) - 21:22, 7 September 2021
- ;(2) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: Installed in staggered and offset layers (not illustrated), and secur ;(3) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Subject to the requirements of Part 8 in the Standard.3 KB (472 words) - 17:57, 27 October 2023
- ;(2) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: Installed in staggered and offset layers (not illustrated), and secur ;(3) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Subject to the requirements of '''Part 8''' in the '''''RoofS3 KB (446 words) - 17:36, 27 October 2023
- ...('''5''')('''4'''). In all other cases, a second drainage layer above the insulation is discretionary). Turn the drainage layer up at the perimeter to convey w ;(6) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: XPS insulation, ideally installed in multiple layers that are offset and staggered as illu5 KB (661 words) - 17:37, 27 October 2023
- ;(7) '''Plaza Deck / Planter Interior Assembly''': Extruded polystyrene insulation and filter mat over primary roof membranes. Concrete pavers placed above pr4 KB (513 words) - 18:21, 27 October 2023
- * Insulation to replace any wet materials discovered in cuts ...entrapped air or water, usually over decks with concrete fills or with wet insulation.</td>75 KB (11,617 words) - 21:00, 3 September 2021
- ...roofing materials and components, such as single-ply membranes, flashings, insulation boards, etc. Before adhesives are applied, their compatibility with other :Applying hot asphalt to what will be the concealed side of a material (insulation sheet, felt, etc.) before turning it over and arranging it in place.76 KB (11,565 words) - 18:09, 26 January 2024
- <u>RSI - Roofing / Siding / Insulation</u>. 7500 Old Oak Boulevard, Cleveland, OH 44130.4 KB (548 words) - 14:32, 18 August 2023
- ===[[RoofStar Guarantee Standards for EPDM Membrane Systems#EPDMINSULATION | Insulation]] === :<big><big>Composite Board Insulation</big></big>5 KB (633 words) - 20:30, 26 July 2021
- ===[[RoofStar Guarantee Standards for TPO Membrane Systems#TPOINSULATION | Insulation]]=== :<big><big>Composite Board Insulation</big></big>5 KB (614 words) - 20:30, 26 July 2021
- ...php?title=RoofStar_Guarantee_Standards_for_ASM_Roof_Assemblies#ASMINS '''5 Insulation'''] and [http://rpm.rcabc.org/index.php?title=RoofStar_Guarantee_Standards_4 KB (582 words) - 21:35, 30 October 2017
- ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (584 words) - 15:27, 26 February 2024
- ;(2) [[TPO Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[TPO Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (599 words) - 22:20, 23 February 2024
- ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ...adhered or mechanically fastened. Two layers required over heat-sensitive insulation.3 KB (416 words) - 18:00, 27 October 2023
- ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Where required.3 KB (334 words) - 18:01, 27 October 2023
- ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']] ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: As required.3 KB (374 words) - 17:46, 27 October 2023
- ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: As required.4 KB (474 words) - 17:59, 27 October 2023
- ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]:3 KB (402 words) - 17:50, 27 October 2023
- ;(2) [[EPDM Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[EPDM Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (580 words) - 16:27, 26 February 2024
- ...lashing must be 200mm (8") in height above the top of extruded polystyrene insulation or protection/drainage layer, extended under the window mullion (fenestrati ...[[SBS Roof Systems Standard#PART_11|'''Protection/Drainage Layer''']] '''- Insulation Surfacing''': Assemblies to be determined by Design Authority. Paver system4 KB (508 words) - 18:51, 27 June 2022
- ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C|'''Accepted Materials''']] section of this Man ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Where required.3 KB (386 words) - 21:52, 16 September 2022
- ...r glass board insulation complying to ASTM C552-00 <b>OR</b> mineral fiber insulation conforming to CAN / CGSB 51.31-M84 and ASTM E84.3 KB (360 words) - 18:52, 21 September 2022
- ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: As required.3 KB (377 words) - 18:21, 27 October 2023
- ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: As required.3 KB (344 words) - 18:18, 27 October 2023
- ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in Division C of this ''Manual''. ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: As required.3 KB (381 words) - 18:47, 27 June 2022
- ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]:3 KB (418 words) - 18:15, 27 October 2023
- ===[[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMINS | Insulation]] === :<big><big>Composite Board Insulation</big></big>5 KB (576 words) - 20:33, 26 July 2021
- ! XPS Insulation<br>Thickness !! Stone Ballast Required Weight !! Ballast Depth<br>(approxim | Insulation || #12 || 73.03 mm (2-7/8”) Hexagonal, 76.2 mm (3”) Round or Square55 KB (7,359 words) - 21:22, 3 October 2023
- ...pm.rcabc.org/index.php?title=SBS_Roof_Systems_Standard#PART_7 {{hilite | 7 INSULATION || 2020-October-21 }}] ...pm.rcabc.org/index.php?title=SBS_Roof_Systems_Standard#PART_8 {{hilite | 8 INSULATION OVERLAYS || 2020-October-21 }}]3 KB (366 words) - 18:42, 30 August 2021
- ::[http://rpm.rcabc.org/index.php?title=EPDM_Roof_Systems_Standard#PART_7 7 INSULATION] ...m.rcabc.org/index.php?title=EPDM_Roof_Systems_Standard#PART_8 {{hilite | 8 INSULATION OVERLAYS|| 2021-February-7 }}]2 KB (343 words) - 18:18, 31 August 2021
- ::[http://rpm.rcabc.org/index.php?title=TPO_Roof_Systems_Standard#PART_7 7 INSULATION] ...pm.rcabc.org/index.php?title=TPO_Roof_Systems_Standard#PART_8 {{hilite | 8 INSULATION OVERLAYS|| 2021-February-7 }}]2 KB (335 words) - 18:43, 30 August 2021
- ...c.org/index.php?title=ASM_Roof_Systems_Standard#ASMINSULATION {{hilite | 7 INSULATION || 2019-November-9 }}]3 KB (338 words) - 16:00, 2 September 2021
- ...cabc.org/index.php?title=Asphalt_Shingle_Systems_Standard#AShINSULATION 7 INSULATION]2 KB (317 words) - 16:03, 31 August 2021
- ::[http://rpm.rcabc.org/index.php?title=PVC_Roof_Systems_Standard#PART_7 7 INSULATION] ...pm.rcabc.org/index.php?title=PVC_Roof_Systems_Standard#PART_8 {{hilite | 8 INSULATION OVERLAYS|| 2021-February-7 }}]2 KB (333 words) - 20:29, 30 August 2021
- ==== [[Roof Deck Insulation]] ==== :'''Fibreboard Roof Insulation'''3 KB (319 words) - 17:34, 22 November 2016
- ==== [[Roof Deck Insulation]] ==== :'''Tapered Insulation'''2 KB (254 words) - 17:18, 6 June 2016
- ==== [[Roof Deck Insulation]] ==== :'''Tapered Insulation'''2 KB (254 words) - 17:18, 6 June 2016
- <big><big><big><big><big>Roofs: Insulation Overlays</big></big></big></big></big><br> Insulation overlays are used to separate the roof membrane from the primary insulation, usually for one of two reasons:3 KB (334 words) - 18:08, 16 June 2023
- :[[Insulation Joints and Overlay|Insulation Joints and Overlay Boards]] [[Insulating the Roof|Low Slope roofs: all about insulation]]7 KB (990 words) - 20:54, 2 August 2016
- ...lso Accepted Roof Deck Insulation products by clicking on this [[Roof Deck Insulation|link]]. ...ed from fluorocarbon vapour trapped in the foam's cells. Polyurethane roof insulation boards are generally available in either:3 KB (444 words) - 17:15, 17 June 2016
- ...lso Accepted Roof Deck Insulation products by clicking on this [[Roof Deck Insulation|link]]. ...varying from 16 to 48 kg / cu.m (1 to 3 lb / cu.ft). Expanded polystyrene insulation is commonly referred to as “beadboard” or “popcorn”3 KB (422 words) - 17:14, 17 June 2016
- #Compressible insulation is to be installed between the sheathing and the wall and an accepted expan =Part 7 INSULATION=117 KB (13,071 words) - 18:36, 5 April 2024
- <div class="mw-collapsible-content">{{Materials - Insulation Overlay (Asphaltic Board)}}</div> ...ndex.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPINSULATION Insulation]===7 KB (968 words) - 20:34, 26 July 2021
- ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual. ...yed (3A: 2- part low rising insulation adhesive, specifically used to bond insulation and cover boards)3 KB (439 words) - 21:37, 27 June 2022
- ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (561 words) - 15:51, 26 February 2024
- ;(2) [[TPO Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[TPO Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (596 words) - 22:32, 23 February 2024
- ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:6 KB (858 words) - 16:09, 16 February 2024
- ...Stagger end joints of insulation a minimum of 300 mm. Mechanically fasten insulation to the deck with screws and 75 mm plates in accordance with current recomme ...m and warm the adhesive stripes. Install the sheet by rolling out onto the insulation, adhered at the striped locations. Lap side joints 76 mm and end joints 15022 KB (3,408 words) - 18:30, 9 November 2016
- ...hot steep roofing asphalt; apply to any prepared roof substrate or roofing insulation suitable for hot applied roofing asphalt, or to a mechanically attached bas ...odified bitumen adhesives; apply to any prepared roof substrate or roofing insulation suitable for modified bitumen adhesives, or to a mechanically attached base12 KB (1,817 words) - 19:27, 7 November 2016
- ...and its suitability to a particular slope is governed by the type of deck, insulation and fastening capability, application method, perceived stresses on the mem <u>INSULATION</u>14 KB (2,024 words) - 18:30, 9 November 2016
- ...d 2-ply (or more) system on flat, curved or domed roofs over most types of insulation. ...nd its suitability for a particular slope is governed by the type of deck, insulation used, fastening capability, application method, type of finished surface of8 KB (1,192 words) - 19:52, 7 November 2016
- ...and its suitability to a particular slope is governed by the type of deck, insulation and fastening capability, application method, perceived stresses on the mem <u>INSULATION</u>11 KB (1,543 words) - 18:21, 9 November 2016
- ...r with 50 mm (2") side laps and 100 mm (4") end laps, adhering with Tremco Insulation Adhesive or Fas’N’Free Adhesive. <u>INSULATION</u>7 KB (942 words) - 20:12, 7 November 2016
- # Do not apply roofing insulation or membrane to damp deck surface. ...) fastener per ply (including the membrane) at each insulation stop. Place insulation stops as per '''''RoofStar Guarantee Standards'''''. On non-insulated syst16 KB (2,588 words) - 18:14, 9 November 2016
- ...um modified asphalt intended for use with glass felts, modified membranes, insulation and coverboards with slopes of 0:12 to 3:12 (May be suitable for other stee8 KB (1,205 words) - 18:26, 9 November 2016
- # For use in “protected membrane” applications under insulation. ...mbrane combinations and their application method is governed by deck type, insulation and fastening capability, perceived stress and required finish. Please cons12 KB (1,673 words) - 19:42, 7 November 2016
- <u>INSULATION</u> # Nailable Decks: mechanically fasten insulation as per manufacturer's recommended method and to '''''RoofStar Guarantee Sta13 KB (1,969 words) - 19:40, 7 November 2016
- # For non-nailable decks and nailable decks with insulation, the cap sheet must be cut to conform to the spacing of nailers. Using capp # For nailable decks with no insulation, the cap sheet must be cut to conform to nailer spacing. Using capped nails21 KB (3,147 words) - 19:39, 7 November 2016
- ## <u>INSULATION AND INSULATION OVERLAY</u> ### Mechanically fasten insulation over nailable decks according to <i>RGC Guarantee Standards</i>.19 KB (2,786 words) - 16:54, 4 November 2016
- ...hen install polyethylene sheeting prior to installing extruded polystyrene insulation, woven polyolefin fabric and ballast. ...uot;) end laps, adhering with ribbons of THERMastic, hot asphalt or Tremco insulation adhesive.20 KB (2,976 words) - 16:55, 4 November 2016
- ## <u>INSULATION</u> <td>Insulation</td>7 KB (992 words) - 16:56, 4 November 2016
- ...hot steep roofing asphalt; apply to any prepared roof substrate or roofing insulation suitable for hot applied roofing asphalt, or to a mechanically attached bas ### Insulation: the following are approved for use with the specified membrane25 KB (3,685 words) - 16:52, 4 November 2016
- ### Do not apply roofing insulation or membrane to damp deck surface. ...) fastener per ply (including the membrane) at each insulation stop. Place insulation stops as per RGC Guarantee Standards (Section 2,1,1)). On non-insulated sys22 KB (3,005 words) - 17:17, 4 November 2016
- ...entire membrane; surface with polyethylene prior to installing polystyrene insulation, scrim and ballast. ...install ballast; surface with polyethylene prior to installing polystyrene insulation, scrim and ballast.21 KB (3,244 words) - 22:15, 7 November 2016
- <td style='border:1px solid black;' nowrap>Insulation</td> <td style='border:1px solid black;' nowrap>Insulation Attachment</td>46 KB (7,081 words) - 22:47, 7 November 2016
- :;Insulation # Vapour Retarder: for protection of the insulation, a vapour retarder should be considered.30 KB (4,433 words) - 22:21, 7 November 2016
- ::For protection of the insulation, a vapour retarder should be considered. # Insulation must be compatible with roof membrane systems.20 KB (3,027 words) - 23:04, 7 November 2016
- # Insulation and underlayment must be stored so it is kept dry and is protected from the :Insulation Fastening Plates: nominal 3 inch diameter plate for use with appropriate Ca9 KB (1,324 words) - 17:09, 8 November 2016
- .1 As a loose-laid system, UltraPly TPO is laid over a free-floating insulation or separation layer, and held in place by gravel ballast. .2 A Fully Adhered System uses a mechanically attached substrate (insulation, separation layer, or pre-approved deck type) and adhesive to bond the memb24 KB (3,556 words) - 22:15, 13 November 2020
- :.1 Insulation: the following are approved for use with the specified membrane. ::Extruded Polystyrene Insulation: minimum 103kPa (15 psi) compressive strength.12 KB (1,686 words) - 17:07, 8 November 2016
- ...may be required as a thermal barrier between steel deck and combustible insulation (see Building Code).</td> <td align="left" valign="top" nowrap style='border:1px solid black;'>Insulation</td>30 KB (4,666 words) - 17:04, 8 November 2016
- ::.1 Mechanically fasten insulation boards with fasteners and plates. ...lystyrene insulations: loose lay Sarnafabric as a separation sheet between insulation and membrane; mechanically fasten separation sheet to substrate at overlaps42 KB (6,360 words) - 18:54, 9 November 2016
- ::*Insulation (If Specified) ...membrane, expansion joints, membrane protection layer, drainage layer and insulation shall be the responsibility of the waterproofing applicator to ensure undiv22 KB (3,157 words) - 18:55, 9 November 2016
- ...s are mopped applied or mechanically fastened to the prepared substrate or insulation. :.1 Insulation: the following are approved for use with the specified membrane36 KB (5,546 words) - 18:22, 8 November 2016
- ...or nailed-on or torched over underlay; apply to any prepared roof deck or insulation. :.1 <b>Insulation:</b> the following are approved for use with the specified membrane.18 KB (2,577 words) - 20:02, 8 November 2016
- :.1 Do not apply roofing insulation or membrane to damp deck surface.11 KB (1,769 words) - 18:24, 9 November 2016
- ::.1 CAN/ULC-S701-[05], Standard for Thermal Insulation, Polystyrene, Boards and Pipe Covering. :.6 Store insulation protected from [daylight] [and] [weather] [___] and deleterious materials.23 KB (2,972 words) - 19:49, 9 November 2016
- ::.1 CAN/ULC-S701- [97], Standard for Thermal Insulation, Polystyrene, Boards. :.6 Store insulation protected from [sunlight] [and] [weather] and deleterious materials.18 KB (2,262 words) - 19:50, 9 November 2016
- ::.1 CAN/ULC-S701-[05], Standard for Thermal Insulation, Polystyrene, Boards and Pipe Covering. ...printed product literature, specifications and datasheets for [membranes] [insulation] and include product characteristics, performance criteria, physical size,19 KB (2,419 words) - 19:52, 9 November 2016
- ::.1 CAN/ULC-S701-[01], Standard for Thermal Insulation, Polystyrene, Boards and Pipe Covering. :.5 Store insulation protected from [sunlight] [and] [weather] and deleterious materials.18 KB (2,332 words) - 19:53, 9 November 2016
- :.1 Do not apply roofing insulation or membrane to damp deck surface.8 KB (1,226 words) - 22:34, 9 November 2016
- ...elements should be clear of overburden and soil to achieve the electrical insulation and avoid unintended grounds.12 KB (1,634 words) - 22:57, 9 November 2016
- ...elements should be clear of overburden and soil to achieve the electrical insulation and avoid unintended grounds.12 KB (1,693 words) - 22:58, 9 November 2016
- ...bstructed air movement of 63 mm (2.5"), between the roof sheathing and the insulation where joist spaces are not individually vented, the spaces must be cross-st ...t less than 63 mm (2.5") of space shall be provided between the top of the insulation and the underside of the roof sheathing.27 KB (4,173 words) - 20:44, 3 September 2021
- ===[[RoofStar Guarantee Standards for BUR Roof Assemblies#BURINSULATION | Insulation]]=== :<big><big>Composite Board Insulation</big></big>5 KB (673 words) - 20:32, 26 July 2021
- * Use a protective base sheet on all wood decks and over ignitable insulation, can strips or other flammable surfaces. ...all ignitable insulation surfaces, edges and over all joints between rigid insulation boards. The base ply provides a protective covering for underlying ignitab15 KB (2,413 words) - 19:01, 23 October 2017
- ...r_SBS-Modified_Bitumen_Membrane_Systems_(revised)#PART_7 {{hilite | Part 7 Insulation || 2020-October-21 }}] ...r_SBS-Modified_Bitumen_Membrane_Systems_(revised)#PART_8 {{hilite | Part 8 Insulation Overlays || 2020-October-21 }}]3 KB (424 words) - 13:52, 27 August 2021
- ===[[RoofStar Guarantee Standards for PVC Membrane Systems#PVCINSULATION | Insulation]]=== :<big><big>Composite Board Insulation</big></big>5 KB (611 words) - 20:30, 26 July 2021
- ;(3) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Offset and stagger layers 300 mm (12"). ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material.3 KB (425 words) - 18:24, 28 June 2022
- ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (602 words) - 15:37, 26 February 2024
- ;(2) [[TPO Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[TPO Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (577 words) - 22:16, 23 February 2024
- ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (582 words) - 15:27, 26 February 2024
- ;(2) [[TPO Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[TPO Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (596 words) - 22:28, 23 February 2024
- ...rs, or to serve as a thermal barrier between the roof deck and combustible insulation. Roof ''deck'' overlay materials may also be applied to other types of sup ...asphalt shingles and the ''deck''). However, it is important to note that insulation also cannot be applied directly beneath the roof deck, for two critical rea27 KB (3,999 words) - 15:35, 14 November 2023
- ...ng system'' is defined by whatever is placed on the membrane, which may be insulation, ballast, pavers or overburden. These materials will displace water and th ...em'' could cause considerable damage to ''roof system'' components such as insulation. || 2023-June-16 }}59 KB (8,538 words) - 18:07, 2 April 2024
- ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (584 words) - 15:38, 26 February 2024
- ;(2) [[EPDM Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[EPDM Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (577 words) - 15:01, 16 February 2024
- ;(2) [[EPDM Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[EPDM Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (600 words) - 15:02, 16 February 2024
- ;(2) [[EPDM Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[EPDM Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:6 KB (837 words) - 15:01, 16 February 2024
- ;(2) [[EPDM Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[EPDM Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (596 words) - 15:30, 16 February 2024
- ;(2) [[EPDM Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[EPDM Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (598 words) - 15:24, 16 February 2024
- ;(2) [[EPDM Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[EPDM Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:5 KB (617 words) - 15:47, 16 February 2024
- ;(2) [[PVC Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[PVC Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:6 KB (839 words) - 15:04, 16 February 2024
- ;(2) [[PVC Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[PVC Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (576 words) - 15:09, 16 February 2024
- ;(2) [[EPDM Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[EPDM Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (599 words) - 16:28, 26 February 2024
- ;(2) [[EPDM Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[EPDM Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (601 words) - 16:29, 26 February 2024
- ;(2) [[EPDM Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[EPDM Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:5 KB (620 words) - 16:30, 26 February 2024
- ;(2) [[TPO Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[TPO Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:6 KB (842 words) - 16:35, 26 February 2024
- ;(2) [[TPO Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[TPO Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (580 words) - 16:36, 26 February 2024
- ;(2) [[TPO Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[TPO Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (602 words) - 16:37, 26 February 2024
- ;(2) [[TPO Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[TPO Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (599 words) - 16:38, 26 February 2024
- ;(2) [[TPO Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[TPO Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (599 words) - 16:38, 26 February 2024
- ;(2) [[TPO Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[TPO Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:5 KB (617 words) - 16:39, 26 February 2024
- ;(2) [[PVC Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[PVC Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:6 KB (842 words) - 16:41, 26 February 2024
- ;(2) [[PVC Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[PVC Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (579 words) - 16:42, 26 February 2024
- ;(2) [[PVC Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[PVC Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (601 words) - 16:42, 26 February 2024
- ;(2) [[PVC Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[PVC Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (600 words) - 16:43, 26 February 2024
- ;(2) [[PVC Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[PVC Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (601 words) - 16:44, 26 February 2024
- ;(2) [[PVC Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[PVC Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:5 KB (619 words) - 16:44, 26 February 2024
- #Compressible insulation is to be installed between the sheathing and the wall and an accepted expan =Part 7 INSULATION=117 KB (13,068 words) - 18:35, 5 April 2024
- ;(2) [[PVC Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[PVC Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (598 words) - 15:29, 16 February 2024
- ;(2) [[PVC Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[PVC Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (597 words) - 15:31, 16 February 2024
- ;(2) [[PVC Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[PVC Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (598 words) - 15:24, 16 February 2024
- ;(2) [[PVC Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[PVC Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (616 words) - 15:26, 16 February 2024
- ...rs, or to serve as a thermal barrier between the roof deck and combustible insulation. Roof ''deck'' overlay materials may also be applied to other types of sup ...ge. Therefore, refer to the "Long-term Thermal Resistance" (LTTR) for each insulation product, in relation to the product's placement within the roof assembly an32 KB (4,655 words) - 13:53, 9 April 2024
- ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: Installed in staggered and offset layers (not fully illustrated), and ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Subject to the requirements of '''Part 8''' in the '''''RoofS4 KB (613 words) - 17:37, 27 October 2023
- ...Standard#PART_5|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.3 KB (383 words) - 22:12, 27 June 2022
- ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.3 KB (444 words) - 22:19, 27 June 2022
- ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual. ...yed (3A: 2- part low rising insulation adhesive, specifically used to bond insulation and cover boards)3 KB (439 words) - 22:16, 27 June 2022
- ...olspan="1" rowspan="2" style="vertical-align:center;text-align:center;" | Insulation<br>Overlay ...olspan="1" rowspan="2" style="vertical-align:center;text-align:center;" | Insulation18 KB (2,674 words) - 16:27, 15 November 2021
- ;(2) [[TPO Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[TPO Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:6 KB (839 words) - 22:13, 23 February 2024
- ====Insulation==== ====Insulation Overlay Panels====7 KB (897 words) - 18:41, 8 June 2023
- ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation<br>Overlay ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation213 KB (30,117 words) - 17:36, 18 November 2021
- :<big>[[Miscellaneous wordings 1 | Effective R-Value Calculator for sloped insulation]]</big>4 KB (536 words) - 14:57, 16 February 2024
- ...olspan="1" rowspan="2" style="vertical-align:center;text-align:center;" | Insulation<br>Overlay ...olspan="1" rowspan="2" style="vertical-align:center;text-align:center;" | Insulation9 KB (1,263 words) - 16:26, 18 November 2021
- A few roof systems were tested without insulation. Most of these were tested on a plywood deck, but some were tested on stee ...may be required, which may then preclude its use - for example, adding an insulation overlay panel where none was tested, because the assembly design requires o9 KB (1,452 words) - 16:41, 18 November 2021
- ...olspan="1" rowspan="2" style="vertical-align:center;text-align:center;" | Insulation<br>Overlay ...olspan="1" rowspan="2" style="vertical-align:center;text-align:center;" | Insulation18 KB (2,683 words) - 16:29, 15 November 2021
- ...olspan="1" rowspan="2" style="vertical-align:center;text-align:center;" | Insulation<br>Overlay ...olspan="1" rowspan="2" style="vertical-align:center;text-align:center;" | Insulation18 KB (2,682 words) - 16:29, 15 November 2021
- ...ng system'' is defined by whatever is placed on the membrane, which may be insulation, ballast, pavers or overburden. These materials will displace water and th ...em'' could cause considerable damage to ''roof system'' components such as insulation. || 2023-June-16 }}57 KB (8,227 words) - 18:02, 2 April 2024
- ...ng system'' is defined by whatever is placed on the membrane, which may be insulation, ballast, pavers or overburden. These materials will displace water and th ...em'' could cause considerable damage to ''roof system'' components such as insulation. || 2023-June-16 }}57 KB (8,227 words) - 18:07, 2 April 2024
- ...rs, or to serve as a thermal barrier between the roof deck and combustible insulation. Roof ''deck'' overlay materials may also be applied to other types of sup ...ge. Therefore, refer to the "Long-term Thermal Resistance" (LTTR) for each insulation product, in relation to the product's placement within the roof assembly an31 KB (4,535 words) - 15:47, 27 October 2023
- ...rs, or to serve as a thermal barrier between the roof deck and combustible insulation. Roof ''deck'' overlay materials may also be applied to other types of sup ...asphalt shingles and the ''deck''). However, it is important to note that insulation also cannot be applied directly beneath the roof deck, for two critical rea27 KB (3,996 words) - 15:35, 14 November 2023
- ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation<br>Overlay ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation5 KB (586 words) - 18:01, 18 November 2021
- ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation<br>Overlay ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation5 KB (603 words) - 18:01, 18 November 2021
- ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation<br>Overlay ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation5 KB (572 words) - 18:02, 18 November 2021
- ====Insulation==== ====Insulation Overlay Panels====6 KB (821 words) - 19:14, 31 January 2024
- ====Insulation==== :'''EPS Insulation'''3 KB (315 words) - 16:23, 1 February 2024
- ====Insulation==== ====Insulation Overlay Panels====8 KB (1,008 words) - 22:38, 30 January 2024
- ...ng system'' is defined by whatever is placed on the membrane, which may be insulation, ballast, pavers or overburden. These materials will displace water and th ...em'' could cause considerable damage to ''roof system'' components such as insulation. || 2023-June-16 }}61 KB (8,812 words) - 18:01, 2 April 2024
- ;(2) [[TPO Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[TPO Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (614 words) - 22:36, 23 February 2024
- ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:6 KB (861 words) - 15:55, 26 February 2024
- ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (564 words) - 15:56, 26 February 2024
- ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (587 words) - 15:57, 26 February 2024
- ;(2) [[EPDM Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[EPDM Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:6 KB (840 words) - 16:26, 26 February 2024
- ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (585 words) - 15:58, 26 February 2024
- ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (587 words) - 15:59, 26 February 2024
- ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (605 words) - 16:00, 26 February 2024
- ;(2) [[EPDM Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[EPDM Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:4 KB (603 words) - 16:27, 26 February 2024
- ...heir protective surfacing will allow many minor anomalies, such as deck or insulation unevenness, to readily telescope through to the roof surface. Over time, d33 KB (4,674 words) - 16:01, 9 September 2021
- ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation<br>Overlay ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation10 KB (1,336 words) - 17:39, 18 November 2021
- ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation<br>Overlay ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation11 KB (1,416 words) - 17:39, 18 November 2021
- ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation<br>Overlay ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation5 KB (662 words) - 17:40, 18 November 2021
- ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation<br>Overlay ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation8 KB (1,003 words) - 17:40, 18 November 2021
- ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation<br>Overlay ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation246 KB (34,400 words) - 18:00, 18 November 2021
- ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation<br>Overlay ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation14 KB (1,827 words) - 17:38, 18 November 2021
- ...owspan="2" style="width:150px;vertical-align:center;text-align:center;" | Insulation<br>Overlay ...owspan="2" style="width:150px;vertical-align:center;text-align:center;" | Insulation309 KB (42,619 words) - 17:38, 18 November 2021
- ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation<br>Overlay ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation8 KB (993 words) - 17:36, 18 November 2021
- ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation<br>Overlay ...owspan="2" style="width:140px;vertical-align:center;text-align:center;" | Insulation28 KB (3,792 words) - 17:37, 18 November 2021
- :<big>[http://{{SERVERNAME}}/index.php?title=Insulation_Joints_and_Overlays Insulation Joints and Overlays<i class="fa fa-angle-double-right"></i>]</big>3 KB (468 words) - 21:32, 18 November 2022
- | [[#PART_7 | Part 7 - Insulation]] ...{hilite | insulated ''systems'', in which metal panels are installed above insulation and other roof system materials, and secured to the ''roof deck'' using the260 KB (36,048 words) - 21:32, 5 April 2024
- | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]465 KB (62,116 words) - 21:20, 5 April 2024
- | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]423 KB (57,312 words) - 21:21, 5 April 2024
- | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]420 KB (56,956 words) - 21:23, 5 April 2024
- | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]415 KB (56,426 words) - 21:31, 5 April 2024
- | [[#PART_7 | PART 7 - Insulation]] <li>{{hilite | thermal resistance || 2023-June-16 }} ([[#Part 7 - Insulation | Part 7]],235 KB (33,160 words) - 21:33, 5 April 2024
- | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]294 KB (41,687 words) - 21:32, 5 April 2024
- | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]466 KB (62,225 words) - 22:19, 5 April 2024
- <big>'''Classification (i.e., Architectural Metal Roofing, Insulation, Membranes, Asphalt Shingles)'''</big>2 KB (241 words) - 17:30, 10 February 2022
- ...ng system'' is defined by whatever is placed on the membrane, which may be insulation, ballast, pavers or overburden. These materials will displace water and th ...em'' could cause considerable damage to ''roof system'' components such as insulation. || 2023-June-16 }}61 KB (8,848 words) - 18:15, 2 April 2024
- ...ng system'' is defined by whatever is placed on the membrane, which may be insulation, ballast, pavers or overburden. These materials will displace water and th ...em'' could cause considerable damage to ''roof system'' components such as insulation. || 2023-June-16 }}59 KB (8,541 words) - 18:06, 2 April 2024
- ...ng system'' is defined by whatever is placed on the membrane, which may be insulation, ballast, pavers or overburden. These materials will displace water and th ...em'' could cause considerable damage to ''roof system'' components such as insulation. || 2023-June-16 }}57 KB (8,230 words) - 18:16, 2 April 2024
- ...ng system'' is defined by whatever is placed on the membrane, which may be insulation, ballast, pavers or overburden. These materials will displace water and th ...em'' could cause considerable damage to ''roof system'' components such as insulation. || 2023-June-16 }}57 KB (8,230 words) - 18:16, 2 April 2024
- ...ng system'' is defined by whatever is placed on the membrane, which may be insulation, ballast, pavers or overburden. These materials will displace water and th ...roof membrane, while retaining existing ''roof system'' components (i.e., insulation, ballast).41 KB (6,077 words) - 18:11, 2 April 2024
- ...ng system'' is defined by whatever is placed on the membrane, which may be insulation, ballast, pavers or overburden. These materials will displace water and th ...roof membrane, while retaining existing ''roof system'' components (i.e., insulation, ballast).41 KB (6,080 words) - 18:16, 2 April 2024
- ...d). Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Division C|'''Accepted Materials''']] Division of this Ma ...yed (3A: 2- part low rising insulation adhesive, specifically used to bond insulation and cover boards)4 KB (592 words) - 18:24, 21 September 2022
- <big><big>'''Secondary Materials: Insulation & Overlays'''</big></big> ====Insulation====16 KB (2,087 words) - 17:35, 13 June 2023
- | [[#PART_7 | Part 7 - Insulation]] ...{hilite | insulated ''systems'', in which metal panels are installed above insulation and other roof system materials, and secured to the ''roof deck'' using the261 KB (36,152 words) - 22:24, 5 April 2024
- | [[#PART_7 | PART 7 - Insulation]] <li>{{hilite | thermal resistance || 2023-June-16 }} ([[#Part 7 - Insulation | Part 7]],236 KB (33,264 words) - 22:24, 5 April 2024