Difference between revisions of "Accepted Materials - Grade-level Waterproofing"

Jump to: navigation, search

Difference between revisions of "Accepted Materials - Grade-level Waterproofing"

(Fasteners)
Line 22: Line 22:
 
:<big><big>Hot Fluid-Applied, Rubberized Asphalt Membrane</big></big>
 
:<big><big>Hot Fluid-Applied, Rubberized Asphalt Membrane</big></big>
 
<div class="toccolours mw-collapsible mw-collapsed"><div class="mw-collapsible-content">{{Template:Materials - Waterproofing Membranes (Hot-applied Rubberized Asphalt)}}</div>
 
<div class="toccolours mw-collapsible mw-collapsed"><div class="mw-collapsible-content">{{Template:Materials - Waterproofing Membranes (Hot-applied Rubberized Asphalt)}}</div>
 
+
===Membrane Protection Boards===
 +
:A RoofStar-accepted membrane protection layer (asphalt core board, cap sheet or protection mat), <u>must</u> be installed by the waterproofing contractor, and be compatible with waterproofing membrane. The protection layer shall be installed and secured, as soon as possible, upon completion of waterproofing membrane installation. Construction traffic, by other than waterproofing trade and membrane moisture monitor technicians, is not permitted until the membrane protection layer is completely installed and secured.
 +
<div class="toccolours mw-collapsible mw-collapsed"><div class="mw-collapsible-content">{{Materials - Insulation Overlay (Proprietary)}}</div>
 
===Accessories===
 
===Accessories===
 
===Leak Detection Systems===
 
===Leak Detection Systems===

Revision as of 21:11, 4 October 2016

To view materials in any section listed below, click on the EXPAND button located at the right hand side of this page

1 Vapour Retarders

The RCABC does not specify Vapour Retarders, as they are not included in the RoofStar Guarantee Program. See manufacturer specifications where Vapour Retarders are required, and refer to proprietary products and installation instructions. This cross-reference is listed for information only.

2 Deck Overlay Boards

Insulation
Insulation Overlay Boards
Insulation Joint Tape

3 Membranes

Modified Bituminous (SBS) Membranes
Expand
Thermoset Membranes (PVC)
Expand
Thermoplastic Membranes (Butyl)
Expand
Hot Fluid-Applied, Rubberized Asphalt Membrane
Expand

4 Membrane Protection Boards

A RoofStar-accepted membrane protection layer (asphalt core board, cap sheet or protection mat), must be installed by the waterproofing contractor, and be compatible with waterproofing membrane. The protection layer shall be installed and secured, as soon as possible, upon completion of waterproofing membrane installation. Construction traffic, by other than waterproofing trade and membrane moisture monitor technicians, is not permitted until the membrane protection layer is completely installed and secured.
Expand

5 Accessories

6 Leak Detection Systems

Expand




Waterproofing Plazas, Promenades and Terraces

Accepted Materials

Special Applications