Difference between revisions of "RCABC Roofing Practices Manual"
Difference between revisions of "RCABC Roofing Practices Manual"
| Line 5: | Line 5: | ||
<div class="panel-heading"><big>Welcome to the RCABC RoofStar '''Roofing Practices Manual''' ('''RPM''')</big></div> | <div class="panel-heading"><big>Welcome to the RCABC RoofStar '''Roofing Practices Manual''' ('''RPM''')</big></div> | ||
<div class="panel-body"> | <div class="panel-body"> | ||
| − | <big>This is the official version of the '''Roofing Practices Manual''' and supersedes all other printed versions which may be in circulation.</big> | + | <big>This is the official version of the '''Roofing Practices Manual''' and supersedes all other printed or printable versions which may be in circulation.</big> |
| − | The '''Roofing Practices Manual''' is ''the'' official guide for RCABC Members, Accepted | + | The '''Roofing Practices Manual''' is ''the'' official guide for RCABC Members, Accepted Observers, consultants, architects and specification writers designing or applying roofing and Waterproofing or Water-shedding systems, and describes the '''''RoofStar Guarantee Standards''''', Guiding Principles and Recommended Practices necessary to qualify for a RoofStar Guarantee. The RPM meets or exceeds the current national and provincial standards for construction and wind uplift design resistance. See the Table of Contents below, or use any of the following quick links: |
<div class="col-md-2"> | <div class="col-md-2"> | ||
| − | [http://rpm.rcabc.org/index.php?title= | + | [http://rpm.rcabc.org/index.php?title=Division_C:_Accepted_Materials <i class="fa fa-star" aria-hidden="true"></i> '''Accepted Materials'''] |
</div> | </div> | ||
<div class="col-md-2"> | <div class="col-md-2"> | ||
| Line 18: | Line 18: | ||
</div> | </div> | ||
<div class="col-md-2"> | <div class="col-md-2"> | ||
| − | [http://rpm.rcabc.org/index.php?title= | + | [http://rpm.rcabc.org/index.php?title=Securing_the_Roof_Assembly <i class="fa fa-flag" aria-hidden="true"></i> '''Wind Uplift Standards'''] |
</div> | </div> | ||
<div class="col-md-2"> | <div class="col-md-2"> | ||
| − | [http://rpm.rcabc.org/index.php?title= | + | [http://rpm.rcabc.org/index.php?title=Division_D:_Waterproofing_Systems_(Roofs) <i class="fa fa-search" aria-hidden="true"></i> '''Waterproofing Systems for roofs'''] |
</div> | </div> | ||
<div class="col-md-2"> | <div class="col-md-2"> | ||
| − | [http://rpm.rcabc.org/index.php?title= | + | [http://rpm.rcabc.org/index.php?title=Division_E:_Water-shedding_Systems <i class="fa fa-search" aria-hidden="true"></i> '''Water-shedding Systems'''] |
</div> | </div> | ||
| − | |||
<div class="col-md-12"> | <div class="col-md-12"> | ||
<hr> | <hr> | ||
| Line 81: | Line 80: | ||
:[http://{{SERVERNAME}}/index.php?title=Materials_by_Product_Type By Product Category] | :[http://{{SERVERNAME}}/index.php?title=Materials_by_Product_Type By Product Category] | ||
:[http://{{SERVERNAME}}/index.php?title=Materials_by_Product_Name By Product Name] | :[http://{{SERVERNAME}}/index.php?title=Materials_by_Product_Name By Product Name] | ||
| − | :[http://{{SERVERNAME}}/index.php?title= | + | :[http://{{SERVERNAME}}/index.php?title=Materials_by_Manufacturer_and_Distributor By Manufacturer] |
:[http://{{SERVERNAME}}/index.php?title=Materials_by_System_Type By System] | :[http://{{SERVERNAME}}/index.php?title=Materials_by_System_Type By System] | ||
| Line 93: | Line 92: | ||
::'''[https://www.nrc-cnrc.gc.ca/eng/services/windrci/agreementvra.html Wind-MVRA calculator]''' | ::'''[https://www.nrc-cnrc.gc.ca/eng/services/windrci/agreementvra.html Wind-MVRA calculator]''' | ||
| − | ::[http://rpm.rcabc.org/index.php?title= | + | ::[http://rpm.rcabc.org/index.php?title=AARS_Tested_Roof_Assemblies <i class="fa fa-caret-right"></i> '''{{hilite | AARS Tested Assemblies || 2021-June-11 }}'''] |
| − | ::[http://rpm.rcabc.org/index.php?title= | + | ::[http://rpm.rcabc.org/index.php?title=PARS_Tested_Roof_Assemblies <i class="fa fa-caret-right"></i> '''{{hilite | PARS Tested Assemblies || 2021-June-11 }}'''] |
| − | ::[http://rpm.rcabc.org/index.php?title= | + | ::[http://rpm.rcabc.org/index.php?title=MARS_Tested_Roof_Assemblies <i class="fa fa-caret-right"></i> '''{{hilite | MARS Tested Assemblies || 2021-June-11 }}'''] |
:[http://{{SERVERNAME}}/index.php?title=SBS_Modified_Bitumen_Membrane_Systems <i class="fa fa-star" aria-hidden="true"></i> {{hilite | SBS Modified Bitumen Membrane Systems || 2021-February-7 }}] | :[http://{{SERVERNAME}}/index.php?title=SBS_Modified_Bitumen_Membrane_Systems <i class="fa fa-star" aria-hidden="true"></i> {{hilite | SBS Modified Bitumen Membrane Systems || 2021-February-7 }}] | ||
| Line 106: | Line 105: | ||
<big>[http://{{SERVERNAME}}/index.php?title=Division_E:_Water-shedding_Systems '''Division E: Water-shedding Systems''']</big> | <big>[http://{{SERVERNAME}}/index.php?title=Division_E:_Water-shedding_Systems '''Division E: Water-shedding Systems''']</big> | ||
| − | :[http://{{SERVERNAME}}/index.php?title= | + | :[http://{{SERVERNAME}}/index.php?title=Architectural_Sheet_Metal_(ASM)_Systems<i class="fa fa-star" aria-hidden="true"></i> {{hilite | Architectural Sheet Metal (ASM) Systems || 2021-February-7 }} ] |
:[http://{{SERVERNAME}}/index.php?title=Asphalt_Shingle_Systems <i class="fa fa-star" aria-hidden="true"></i> {{hilite | Asphalt Shingle Systems || 2021-February-7 }}] | :[http://{{SERVERNAME}}/index.php?title=Asphalt_Shingle_Systems <i class="fa fa-star" aria-hidden="true"></i> {{hilite | Asphalt Shingle Systems || 2021-February-7 }}] | ||
:[http://{{SERVERNAME}}/index.php?title=Cedar_Shake_%26_Shingle_Systems <i class="fa fa-star" aria-hidden="true"></i> Cedar Shake and Shingle Systems] | :[http://{{SERVERNAME}}/index.php?title=Cedar_Shake_%26_Shingle_Systems <i class="fa fa-star" aria-hidden="true"></i> Cedar Shake and Shingle Systems] | ||
Revision as of 14:18, 24 June 2020
This is the official version of the Roofing Practices Manual and supersedes all other printed or printable versions which may be in circulation.
The Roofing Practices Manual is the official guide for RCABC Members, Accepted Observers, consultants, architects and specification writers designing or applying roofing and Waterproofing or Water-shedding systems, and describes the RoofStar Guarantee Standards, Guiding Principles and Recommended Practices necessary to qualify for a RoofStar Guarantee. The RPM meets or exceeds the current national and provincial standards for construction and wind uplift design resistance. See the Table of Contents below, or use any of the following quick links:
NOTICE to Readers: This online presentation of the Roofing Practices Manual is a restructuring of its original format. All updates to the older version of this Manual have been incorporated into the present structure. Yellow highlighted text indicates a change to the Manual within the past 12 months. Watch for changes to either or both Accepted Materials and RoofStar Guarantee Standards. Highlighting remains in effect for 365 days. Consult the Technical Updates for a list of changes since 2010.
Last Update: February 27, 2020 (see Technical Updates for details)
- How to Use the Roofing Practices Manual
- The RoofStar Guarantee Program
- Independent Observations
- Requesting and Specifying a RoofStar Guarantee
Division B: Essential Elements
- Air and Vapour Control
- Building Ventilation
- BUR Materials
- Deck and Wall Overlays
- Design Considerations
- Eave Protection
- Fasteners & Fastening Requirements
- Insulating the Roof
- Insulation Joints and Overlays
- Membrane Surfaces
- Protected and Modified Protected Roof Systems
- Roof Classes
- Roof Decks
- Roof Plans
- Waterproofing Materials
- Water-shedding Materials
Division D: Waterproofing Systems (Roofs)
- SBS Modified Bitumen Membrane Systems
- EPDM Membrane Systems
- TPO Membrane Systems
- PVC Membrane Systems
- Hot Fluid-applied Rubberized Asphalt Systems (TBA)
- PMMA Liquid Systems (TBA)
- Built-up Roof (BUR) Systems
Division E: Water-shedding Systems
- Architectural Sheet Metal (ASM) Systems
- Asphalt Shingle Systems
- Cedar Shake and Shingle Systems
- Tile & Slate Systems
Division F: Grade-level Waterproofing
