Search results

Jump to: navigation, search

Search results

  • ...rity <i class="fa fa-hand-o-right" aria-hidden="true"></i> <big>Materials by Manufacturer, Distributor or Certifying Authority</big>] ...Name <i class="fa fa-hand-o-right" aria-hidden="true"></i> <big>Materials by Product Name</big>]
    732 bytes (97 words) - 16:54, 19 August 2016
  • ...membrane, these products also offer the practical advantages of bituminous materials (i.e. they are generally compatible with asphalt products and may be useful ...and they tend to exhibit &#8220;plastic&#8221; properties. Thermosets are materials in which cross-linking of the molecules occurs and they tend to exhibit &#8
    22 KB (3,281 words) - 21:46, 17 July 2017
  • ...Siplast_NVS_Premix_Product_Info_Sheet.pdf '''Here'''] for '''NVS Premix''' materials handling and application instructions, :* Recover and existing roof system (consultant validated).
    3 KB (474 words) - 21:16, 12 February 2019
  • <big><big>Division C - Accepted Materials</big></big> | style="background-color: #ffffcc; column-width:100%" | {{Template:Accepted Materials Page Header}}
    1 KB (178 words) - 21:51, 7 September 2021
  • <big><big>Division C - Accepted Materials</big></big> *'''Accepted Materials'''
    22 KB (3,050 words) - 16:20, 12 December 2023
  • ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']]. ...a temperature of 1100<sup>o</sup>C (2000<sup>o</sup>F), the flame produced by liquid propane gas does an excellent melting job. But used incorrectly or
    14 KB (2,333 words) - 16:39, 9 February 2022
  • ...include (without limitation) the following (as they are applicable to the type of ''project''): ...by the RGC and listed in the '''''Roofing Practices Manual'''''. Accepted Materials include (without limitation)|| 2021-February-7 }}
    9 KB (1,253 words) - 17:05, 10 December 2021
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    416 KB (56,532 words) - 22:23, 5 April 2024
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    424 KB (57,418 words) - 22:20, 5 April 2024
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    421 KB (57,062 words) - 22:20, 5 April 2024
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    296 KB (41,811 words) - 22:23, 5 April 2024
  • <big><big>Division C - Accepted Materials</big></big> <big><big><big>by Active Member Name</big></big></big><br>
    5 KB (684 words) - 14:23, 27 October 2023
  • ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']]. ...kers, rain, snow, and ice. Dead loads include the deck itself, the roofing system, HVAC units and, possibly, landscaping. Most decks must also act as a diaph
    20 KB (2,969 words) - 16:06, 9 September 2021
  • ...s Part apply to all Standards for all ''projects'' unless expressly varied by the ''Guarantor'' under the terms of the Guarantee issued for a ''project'' ...ot Work. Some tools used in the course of Hot Work can ignite combustible materials, and some building environments are more sensitive to fire than others, suc
    11 KB (1,608 words) - 22:03, 3 May 2021
  • ...y system according to the weather-side surface, and are further divided by system categories - '''Roof Waterproofing Systems''', '''Water-shedding Systems''' :'''Division C: Accepted Materials'''
    15 KB (2,132 words) - 19:02, 18 August 2023
  • ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']]. ...igned to provide an interior environment (or shelter) that is not governed by the exterior environment. The roof is a fundamental component of this desig
    23 KB (3,279 words) - 15:42, 9 September 2021
  • | style="background-color: #ffffcc; column-width:100%" | {{Template:Accepted Materials Page Header}} ...sture detection company, whose moisture detection system has been reviewed by the RCABC Technical Committee and deemed to be suitable for inclusion in th
    2 KB (249 words) - 22:45, 9 November 2016
  • <big><big><big><big><big>Fasteners and Fastening Materials</big></big></big></big></big> ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']].
    7 KB (999 words) - 15:42, 9 September 2021
  • ...e printed and digital editions of Roofing BC, the trade magazine published by the RCABC. You can also watch the video presentation, “Blown Away: Code R ...and in shops and factories. The assembly and integration of these various materials and systems into a finished building requires tremendous coordination, nego
    21 KB (3,118 words) - 16:32, 16 March 2023
  • ...Systems Standard#PART_6|'''Air or Vapour Control Layers''']]: If required by design authority. ...fastened. See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manual''.
    3 KB (440 words) - 18:14, 27 October 2023
  • <big><big><big><big><big>BUR Materials</big></big></big></big></big> ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']].
    15 KB (2,293 words) - 15:33, 9 September 2021
  • <big><big><big><big><big>Waterproofing Materials</big></big></big></big></big> ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']].
    23 KB (3,307 words) - 15:57, 9 September 2021
  • ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']]. ...rom weather exposure to prevent &#8220;wicking&#8221; of moisture into the system. The surfacing material can also provide fire resistance, reflectivity or i
    8 KB (1,280 words) - 16:25, 9 September 2021
  • ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']]. ...w Chemical Co. Much of the initial research on these systems was conducted by the National Research Council of Canada during the late 1950's and early 19
    11 KB (1,624 words) - 16:21, 9 September 2021
  • | style="background-color: #ffffcc; column-width:100%" | {{Template:Accepted Materials Page Header}} ...a broad selection of overlays that could be used in a water-shedding roof system. However, not every material listed here may be suitable for this applicat
    1 KB (185 words) - 14:15, 27 July 2021
  • | style="background-color: #ffffcc; column-width:100%" | {{Template:Accepted Materials Page Header}} :'''See the tables below for tapered products offered by various manufacturers.'''
    2 KB (251 words) - 14:13, 27 July 2021
  • ...he [[Cedar Shake & Shingle Systems Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...ons for second nail. All ridges and hips shall be of the alternate overlap type and at the same exposure as the field of the roof. Each side shall be faste
    3 KB (493 words) - 21:06, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.
    4 KB (458 words) - 21:14, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications.
    4 KB (454 words) - 21:14, 7 September 2021
  • ...tion Layer''']]: Recommended over asphaltic underlays and / or as required by metal panel manufacturer. ....2.1.3. Fasteners |'''Exposed Fasteners''']]: High-domed gasketed cladding type screws compatible with metal roof panel.
    2 KB (297 words) - 18:04, 28 June 2022
  • ...me deck surface to provide a solid or continuous substrate for roof system materials. Here, a deck overlay is provided to support a continuous AVB layer. ...foam closures set in acceptable sealant with high domed gasketed cladding type screws at each standing rib.
    4 KB (540 words) - 17:25, 28 June 2022
  • ...rlayment|'''Underlayment''']]: The type of underlay required is determined by roof slope. ;(3) [[ASM Roof Systems Standard#8.1.3.4. Separation Between Materials|'''Vapour-permeable separation membrane''']]: Installed over insulation and
    3 KB (432 words) - 19:00, 28 June 2022
  • ...rlayment|'''Underlayment''']]: The type of underlay required is determined by roof slope. ;(4) [[ASM Roof Systems Standard#8.1.3.4. Separation Between Materials|'''Vapour-permeable separation membrane''']]: Installed over insulation and
    4 KB (537 words) - 17:35, 17 March 2023
  • ...rlayment|'''Underlayment''']]: The type of underlay required is determined by roof slope. ;(3) [[ASM Roof Systems Standard#8.1.3.4. Separation Between Materials|'''Vapour-permeable separation membrane''']]: Installed over insulation and
    4 KB (530 words) - 20:11, 28 June 2022
  • ...foam closures set in acceptable sealant with high domed gasketed cladding type screws at each standing rib. ...Standard#PART_13 |'''Metal Counter Flashing''']]: Must extend behind wall system and wall control layers. Stucco stops are not considered to be a counter fl
    3 KB (464 words) - 17:31, 28 June 2022
  • ...|'''Underlayment (lower)''']]: The type of underlay required is determined by roof slope. ..., which is tied into underlayment, to ensure any water intrusion into roof system drains into gutter.
    5 KB (611 words) - 18:17, 12 March 2024
  • <big><big><big><big><big>TPO | Conventionally Insulated System (Typical) ([[TPO_Roof_Systems_Standard#1.1.3.1._Permitted_Roof_Systems | Ar ...d depending on insulation thickness or when required as a thermal barrier by design authority.
    3 KB (383 words) - 21:38, 27 June 2022
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...ve: Proprietary primer or adhesive, application and quantities as directed by membrane manufacturers published application specifications.
    4 KB (527 words) - 21:15, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...ive: Proprietary primer or adhesive application and quantities as directed by Membrane Manufacturer's published application specifications.
    4 KB (527 words) - 21:16, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...tandard#WPINSULATION | '''Insulation''']]: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, compressive strength of 240 kpa (35 psi).
    4 KB (596 words) - 21:17, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...ve: Proprietary primer or adhesive, application and quantities as directed by membrane manufacturers published application specifications.
    4 KB (463 words) - 21:18, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...eel channel and concrete pins. Adhered membrane termination held in place by clamping pressure and pins.
    4 KB (475 words) - 21:21, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.
    4 KB (467 words) - 21:21, 7 September 2021
  • ...in the [[Grade-level Waterproofing Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span> ...adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.
    3 KB (413 words) - 21:22, 7 September 2021
  • A roof system is exposed to all manner of chemical and physical stress. The long-term eff * As-built drawings of construction details directly related to the roofing system, such as flashings, deck, etc.
    75 KB (11,617 words) - 21:00, 3 September 2021
  • :The ability of a membrane to resist being worn away by contact with a moving abrasive surface, such as foot traffic, mechanical eq :The process in which materials are exposed to a controlled environment where various phenomena &#8211; suc
    76 KB (11,565 words) - 18:09, 26 January 2024
  • :<u>Test Procedures for Evaluation of Materials:</u> == 11.2.2 <u>Significance of the Reported Physical Properties of Membrane Materials</u> ==
    11 KB (1,753 words) - 15:02, 4 May 2017
  • ...Roof Systems Standard#PART_5|'''Supporting Deck Overlay''']]: If required by design authority. ...Systems Standard#PART_6|'''Air or Vapour Control Layers''']]: If required by design authority.
    3 KB (334 words) - 18:01, 27 October 2023
  • ...Roof Systems Standard#PART_5|'''Supporting Deck Overlay''']]: If required by design authority. ...f Systems Standard#PART_6|'''Air or Vapour Control Layers''']]:If required by design authority.
    3 KB (402 words) - 17:50, 27 October 2023
  • | colspan="2" | <big>To view materials in any section listed below, click on the <span style="color:#6495ed">'''Ex ...terials'''] section of this Manual, as their performance is not guaranteed by the '''''RoofStar Guarantee Program'''''. For more about air and vapour ba
    5 KB (576 words) - 20:33, 26 July 2021
  • ...(2013). The membrane "flutter" in wind is common for this type of ''roof system''). <li>roofs where only part of the ''system'' must be replaced.
    55 KB (7,359 words) - 21:22, 3 October 2023
  • <big><big>Division C - Accepted Materials</big></big> ...ar Guarantee Program'''''. Technical Data Sheets ('''TDS''') may be found by clicking on the product link, unless indicated otherwise.
    2 KB (276 words) - 16:56, 1 February 2023
  • ...contains the Standards, Guiding Principles, Recommendations and reference materials necessary for the design and installation of a roof qualifying for a RoofSt ...ee''''' are found in this section. Readers are advised to review relevant materials that can be accessed through the links available in the body of text or emb
    117 KB (13,071 words) - 18:36, 5 April 2024
  • | colspan="2" | <big>To view materials in any section listed below, click on the <span style="color:#6495ed">'''EX :See the list below for materials acceptable for application on steel decks when specifying a RoofStar Waterp
    7 KB (968 words) - 20:34, 26 July 2021
  • <big><big><big><big><big>TPO | Conventionally Insulated System (Alternate) ([[TPO_Roof_Systems_Standard#1.1.3.1._Permitted_Roof_Systems | ;(1) [[TPO Roof Systems Standard#PART_6|'''Vapour Retarder''']]: If required by design authority.
    3 KB (439 words) - 21:37, 27 June 2022
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. ...welding, adhesive or peel and stick self-adhesive in every type of roofing system.
    22 KB (3,408 words) - 18:30, 9 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. The highest quality raw materials are utilized in a manufacturing process which saturates and coats non-woven
    14 KB (2,024 words) - 18:30, 9 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. ...ed SBS Modified Bituminous membranes in 1978. Only the highest quality raw materials are utilized in a manufacturing process which impregnates and coats fibregl
    8 KB (1,192 words) - 19:52, 7 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. The highest quality raw materials are utilized in a manufacturing process which saturates and coats non-woven
    11 KB (1,543 words) - 18:21, 9 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. The system normally consists of two plies of membrane. The membrane is produced in 1 m
    12 KB (1,673 words) - 19:42, 7 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. ...ination of these. Membranes may be installed either by the torch method or by embedment in hot asphalt.
    13 KB (1,969 words) - 19:40, 7 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. ...mbranes may be installed in hot asphalt, in asphalt cold process adhesive, by heat welding or peel and stick self-adhesive. Ceramic granules for cap shee
    21 KB (3,147 words) - 19:39, 7 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. ## <u>SYSTEM DESCRIPTIONS</u>
    19 KB (2,786 words) - 16:54, 4 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. THERM 100 is a built-up roofing system utilizing THERMastic, a proprietary elastomeric hot-melt adhesive and water
    20 KB (2,976 words) - 16:55, 4 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. ### Deliver and store materials in original packages and containers with manufacturer's seals and labels in
    7 KB (992 words) - 16:56, 4 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. ## <u>SYSTEM DESCRIPTION</u>
    25 KB (3,685 words) - 16:52, 4 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. <i>Product Group:</i> <b>SBS MODIFIED PROPRIETARY BUR SYSTEM</b>
    22 KB (3,005 words) - 17:17, 4 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. <u>SYSTEM DESCRIPTION</u>
    21 KB (3,244 words) - 22:15, 7 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. Distributor: <b>STEELS INDUSTRIAL PRODUCTS, PRO-LINE CONSTRUCTION MATERIALS</b>
    46 KB (7,081 words) - 22:47, 7 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. ...in black or white on black, reinforced or non-reinforced depending on the type of application.
    30 KB (4,433 words) - 22:21, 7 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. ...mbrane is available in black reinforced or non-reinforced depending on the type of application. JM EPDM is manufactured in standard widths up to 12.19 m (4
    20 KB (3,027 words) - 23:04, 7 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. The roofing system / material information published in the <b>RoofStar <i>Roofing Practices Ma
    9 KB (1,324 words) - 17:09, 8 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. The main component of the roofing system is the Firestone Ultra-Ply TPO Membrane, a tough flexible membrane based on
    24 KB (3,556 words) - 22:15, 13 November 2020
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. <u>SYSTEM DESCRIPTION</u>
    12 KB (1,686 words) - 17:07, 8 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. ====[[Johns Manville Corporation|MATERIALS]]====
    30 KB (4,666 words) - 17:04, 8 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. ...fusion process to adjacent sheets or flashings to form an integral roofing system. Larger than standard or different shapes may be prefabricated to suit job
    42 KB (6,360 words) - 18:54, 9 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. ...fusion process to adjacent sheets or flashings to form an integral roofing system. Larger than standard or different shapes may be prefabricated to suit job
    22 KB (3,157 words) - 18:55, 9 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. <u>SYSTEM DESCRIPTION</u>
    36 KB (5,546 words) - 18:22, 8 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. <u>SYSTEM DESCRIPTION</u>
    18 KB (2,577 words) - 20:02, 8 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. ...conditions. The "Teranap" series is Siplast's major waterproofing membrane system. These waterproofing membranes are available with polypropylene film or san
    10 KB (1,477 words) - 18:28, 9 November 2016
  • ...l. The reader is urged to check these against current publications issued by the manufacturer, to ensure accuracy. :The roofing assembly / material information published by the <b>RoofStar <i>Roofing Practices Manual </i></b>does NOT represent a co
    11 KB (1,769 words) - 18:24, 9 November 2016
  • ...ly SBS modified bituminous membranes in a protected membrane waterproofing system. ...pecification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using a Combination of Polyester and Glass Fibre Reinforcements.
    23 KB (2,972 words) - 19:49, 9 November 2016
  • :.1 Materials and installation requirements for polyvinyl chloride (PVC) waterproofing in :.2 American Society for Testing and Materials International, (ASTM).
    18 KB (2,262 words) - 19:50, 9 November 2016
  • :.1 Materials and installation for Butyl (IIR) Sheet Membrane waterproofing in a protecte :.2 American Society for Testing and Materials International, (ASTM).
    19 KB (2,419 words) - 19:52, 9 November 2016
  • :.1 Materials and installation for hot applied rubberized asphalt (HARA) waterproofing in :.2 American Society for Testing and Materials International, (ASTM).
    18 KB (2,332 words) - 19:53, 9 November 2016
  • ...ITORING TECHNOLOGY - WATERPROOF MEMBRANE SURVEY AND LEAK LOCATE MONITORING SYSTEM</b> ...PROJECT OR OFFICE MASTER SPECIFICATIONS. IT FOLLOWS GUIDELINES ESTABLISHED BY THE CONSTRUCTION SPECIFICATIONS INSTITUTE, AND THEREFORE MAY BE USED WITH M
    12 KB (1,693 words) - 22:58, 9 November 2016
  • == Materials == === MATERIALS ===
    27 KB (4,173 words) - 20:44, 3 September 2021
  • | colspan="2" | <big>To view materials in any section listed below, click on the <span style="color:#6495ed">'''EX ...terials'''] section of this Manual, as their performance is not guaranteed by the '''''RoofStar Guarantee Program'''''. For more about air and vapour ba
    5 KB (673 words) - 20:32, 26 July 2021
  • ...y apply. Torch safety best practices remain the same regardless of system type. ...a temperature of 1100<sup>o</sup>C (2000<sup>o</sup>F), the flame produced by liquid propane gas does an excellent melting job. But used incorrectly or
    15 KB (2,413 words) - 19:01, 23 October 2017
  • ...layment |'''Underlayment''']]: The type of underlay required is determined by roof slope. ;(2) Ridge girts: May be required by engineer for panel drag load fasteners. Secured using compatible non-corro
    3 KB (425 words) - 18:24, 28 June 2022
  • ...include (without limitation) the following (as they are applicable to the type of ''project''): ...by the RGC and listed in the '''''Roofing Practices Manual'''''. Accepted Materials include (without limitation)|| 2021-February-7 }}
    9 KB (1,253 words) - 22:33, 12 November 2021
  • ...oncealed fastening. Galvanized steel and wood are the most common ''deck'' materials used with architectural metal roofing. ...Works. Some tools used in the course of Hot Works can ignite combustible materials, and some building environments are more sensitive to fire than others, suc
    27 KB (3,999 words) - 15:35, 14 November 2023
  • ...eded to prevent water ingress. The definition of ''Finished waterproofing system'' is illustrated below in '''Figures 1.3.2-1''' and '''1.3.2-2'''. See als ...hilite | <small>Figure 1.3.2-1(Conventionally Insulated roof waterproofing system)(Click to expand)</small> || 2021-February-7 }}
    59 KB (8,538 words) - 18:07, 2 April 2024
  • ...contains the Standards, Guiding Principles, Recommendations and reference materials necessary for the design and installation of a roof qualifying for a RoofSt ...ee''''' are found in this section. Readers are advised to review relevant materials that can be accessed through the links available in the body of text or emb
    117 KB (13,068 words) - 18:35, 5 April 2024
  • ...oncealed fastening. Galvanized steel and wood are the most common ''deck'' materials used with architectural metal roofing. ...Works. Some tools used in the course of Hot Works can ignite combustible materials, and some building environments are more sensitive to fire than others, suc
    32 KB (4,655 words) - 13:53, 9 April 2024
  • <big><big><big><big><big>PVC | Conventionally Insulated System (Typical) ([[PVC_Roof_Systems_Standard#1.1.3.1._Permitted_Roof_Systems | Ar ...d depending on insulation thickness or when required as a thermal barrier by design authority.
    3 KB (383 words) - 22:12, 27 June 2022
  • ...roof surface. Welded or adhered to primary membrane depending on membrane type. ...ee available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (444 words) - 22:19, 27 June 2022
  • <big><big><big><big><big>PVC | Conventionally Insulated System (Alternate) ([[PVC_Roof_Systems_Standard#1.1.3.1._Permitted_Roof_Systems | ;(1) [[PVC Roof Systems Standard#PART_6|'''Vapour Retarder''']]: If required by design authority.
    3 KB (439 words) - 22:16, 27 June 2022
  • :<big><big><big><big><big>Division C: Accepted Materials</big></big></big></big></big> ...one of the links below to find materials by type, name, producer or by the system under design or construction.
    2 KB (231 words) - 21:48, 14 June 2023
  • ...e formulae in the ''British Columbia Building Code'', 4.1.7 Wind Loads, or by using the National Research Council's online tool, [https://www.nrc-cnrc.gc ...om the "Test Report" column, and are catalogued under a RoofStar numbering system that may differ from the number designation on the report. Dynamic Wind Up
    18 KB (2,674 words) - 16:27, 15 November 2021
  • ;(2) [[Asphalt Shingle Systems Standard#Section 12.2. Materials|'''Penetration flashing''']]:Conforming to material requirements in Article ...eral Requirements for Penetrations|'''Storm collar''']]: Required for pipe-type flashings (see '''11.3.3 Penetrations and Vents'''). Caulked with an untoo
    3 KB (376 words) - 20:36, 2 May 2024
  • ...e formulae in the ''British Columbia Building Code'', 4.1.7 Wind Loads, or by using the National Research Council's online tool, [https://www.nrc-cnrc.gc ...om the "Test Report" column, and are catalogued under a RoofStar numbering system that may differ from the number designation on the report. Dynamic Wind Up
    9 KB (1,263 words) - 16:26, 18 November 2021
  • ;[[MARS Tested Roof Assemblies#Substitutions | Accepted Materials and Material Substitutions]] ...offered without endorsement by the RCABC; they are provided as a courtesy by the '''''RoofStar Guarantee Program''''' to assist the ''Design Authority''
    9 KB (1,452 words) - 16:41, 18 November 2021
  • ...e formulae in the ''British Columbia Building Code'', 4.1.7 Wind Loads, or by using the National Research Council's online tool, [https://www.nrc-cnrc.gc ...om the "Test Report" column, and are catalogued under a RoofStar numbering system that may differ from the number designation on the report. Dynamic Wind Up
    18 KB (2,683 words) - 16:29, 15 November 2021
  • ...e formulae in the ''British Columbia Building Code'', 4.1.7 Wind Loads, or by using the National Research Council's online tool, [https://www.nrc-cnrc.gc ...om the "Test Report" column, and are catalogued under a RoofStar numbering system that may differ from the number designation on the report. Dynamic Wind Up
    18 KB (2,682 words) - 16:29, 15 November 2021
  • ...eded to prevent water ingress. The definition of ''Finished waterproofing system'' is illustrated below in '''Figures 1.3.2-1''' and '''1.3.2-2'''. See als ...hilite | <small>Figure 1.3.2-1(Conventionally insulated roof waterproofing system)(Click to expand)</small> || 2021-February-7 }}
    57 KB (8,227 words) - 18:02, 2 April 2024
  • ...eded to prevent water ingress. The definition of ''Finished waterproofing system'' is illustrated below in '''Figures 1.3.2-1''' and '''1.3.2-2'''. See als ...hilite | <small>Figure 1.3.2-1(Conventionally Insulated roof waterproofing system)(Click to expand)</small> || 2021-February-7 }}
    57 KB (8,227 words) - 18:07, 2 April 2024
  • ...oncealed fastening. Galvanized steel and wood are the most common ''deck'' materials used with architectural metal roofing. ...Works. Some tools used in the course of Hot Works can ignite combustible materials, and some building environments are more sensitive to fire than others, suc
    31 KB (4,535 words) - 15:47, 27 October 2023
  • ...oncealed fastening. Galvanized steel and wood are the most common ''deck'' materials used with architectural metal roofing. ...Works. Some tools used in the course of Hot Works can ignite combustible materials, and some building environments are more sensitive to fire than others, suc
    27 KB (3,996 words) - 15:35, 14 November 2023
  • ...eded to prevent water ingress. The definition of ''Finished waterproofing system'' is illustrated below in '''Figures 1.3.2-1''' and '''1.3.2-2'''. See als ...hilite | <small>Figure 1.3.2-1(Conventionally Insulated roof waterproofing system)(Click to expand)</small> || 2021-February-7 }}
    61 KB (8,812 words) - 18:01, 2 April 2024
  • ...d the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']]. In order to formulate materials to satisfy the requirements of a roof membrane, the manufacturer must ensur
    33 KB (4,674 words) - 16:01, 9 September 2021
  • ...one of the links below to find materials by type, name, producer or by the system under design or construction. ...[http://{{SERVERNAME}}/index.php?title=Materials_by_Product_Type '''Search by Product Category''' <i class="fa fa-angle-double-right"></i>]</big>
    1 KB (206 words) - 17:37, 2 September 2021
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    260 KB (36,048 words) - 21:32, 5 April 2024
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    465 KB (62,116 words) - 21:20, 5 April 2024
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    423 KB (57,312 words) - 21:21, 5 April 2024
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    420 KB (56,956 words) - 21:23, 5 April 2024
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    415 KB (56,426 words) - 21:31, 5 April 2024
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''' o Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    235 KB (33,160 words) - 21:33, 5 April 2024
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    294 KB (41,687 words) - 21:32, 5 April 2024
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    466 KB (62,225 words) - 22:19, 5 April 2024
  • <big><big>Division C - Accepted Materials</big></big> ;'''Product Group - Standing Seam Metal Roof System'''
    4 KB (625 words) - 18:59, 10 February 2022
  • ...eded to prevent water ingress. The definition of ''Finished waterproofing system'' is illustrated below in '''Figures 1.3.2-1''' and '''1.3.2-2'''. See als ...hilite | <small>Figure 1.3.2-1(Conventionally Insulated roof waterproofing system)(Click to expand)</small> || 2021-February-7 }}
    61 KB (8,848 words) - 18:15, 2 April 2024
  • ...eded to prevent water ingress. The definition of ''Finished waterproofing system'' is illustrated below in '''Figures 1.3.2-1''' and '''1.3.2-2'''. See als ...hilite | <small>Figure 1.3.2-1(Conventionally Insulated roof waterproofing system)(Click to expand)</small> || 2021-February-7 }}
    59 KB (8,541 words) - 18:06, 2 April 2024
  • ...eded to prevent water ingress. The definition of ''Finished waterproofing system'' is illustrated below in '''Figures 1.3.2-1''' and '''1.3.2-2'''. See als ...hilite | <small>Figure 1.3.2-1(Conventionally insulated roof waterproofing system)(Click to expand)</small> || 2021-February-7 }}
    57 KB (8,230 words) - 18:16, 2 April 2024
  • ...eded to prevent water ingress. The definition of ''Finished waterproofing system'' is illustrated below in '''Figures 1.3.2-1''' and '''1.3.2-2'''. See als ...hilite | <small>Figure 1.3.2-1(Conventionally Insulated roof waterproofing system)(Click to expand)</small> || 2021-February-7 }}
    57 KB (8,230 words) - 18:16, 2 April 2024
  • ...eded to prevent water ingress. The definition of ''Finished waterproofing system'' is illustrated below in '''Figures 1.3.2-1''' and '''1.3.2-2'''. See also |+{{hilite | <small>Figure 1.3.2-2 (Protected roof system)(Click to expand)</small> || 2021-February-7 }}
    41 KB (6,077 words) - 18:11, 2 April 2024
  • ...eded to prevent water ingress. The definition of ''Finished waterproofing system'' is illustrated below in '''Figures 1.3.2-1''' and '''1.3.2-2'''. See also |+{{hilite | <small>Figure 1.3.2-2 (Protected roof system)(Click to expand)</small> || 2021-February-7 }}
    41 KB (6,080 words) - 18:16, 2 April 2024
  • <big><big>Division C - Accepted Materials</big></big> <tab name="Materials for Waterproofing Roof Systems">
    16 KB (2,087 words) - 17:35, 13 June 2023
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''', Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    261 KB (36,152 words) - 22:24, 5 April 2024
  • ...tain the requirements, guiding principles, recommendations and informative materials necessary for a roof to qualify for a '''''RoofStar 5-Year Guarantee''''' o Notes to the Standard are hyperlinked from each Part and can be read by using the link in the Table of Contents for the Standard. {{hilite |Highli
    236 KB (33,264 words) - 22:24, 5 April 2024