Search results

Jump to: navigation, search

Search results

Page title matches

Page text matches

  • File:11.1.3.5.10.jpg
    ...the organic fibres of the felt which swell into a ridge over each joint of insulation in “picture frame” pattern.
    (519 × 263 (21 KB)) - 20:28, 20 February 2012
  • File:11.1.3.5.7.jpg
    ...eck and insulation, layers of insulation, or built-up roofing membrane and insulation.
    (590 × 185 (23 KB)) - 20:38, 20 February 2012
  • File:11.1.3.5.9.jpg
    ...the organic fibres of the felt which swell into a ridge over each joint of insulation in “picture frame” pattern.
    (576 × 193 (19 KB)) - 20:39, 20 February 2012
  • ...heir protective surfacing will allow many minor anomalies, such as deck or insulation unevenness, to readily telescope through to the roof surface. Over time, d Slope can be provided by sloping the deck, or using tapered insulation boards of insulating fill (insulating fill is rarely used in B.C.). A minim
    0 members (0 subcategories, 0 files) - 16:30, 23 June 2015
  • #REDIRECT [[Insulation Joints and Overlays]]
    44 bytes (5 words) - 15:50, 23 October 2018
  • ...C) test and classify roof assemblies (includes roof deck, vapour retarder, insulation, membrane, etc.), roof components, and (specifically) roof-covering materia
    5 KB (808 words) - 16:06, 9 September 2021
  • ...heet membrane that is factory-laminated to a high-density Polyisocyanurate insulation support panel (SOPRA-ISO PLUS HD). The panel may be installed with hot bit
    2 KB (326 words) - 17:20, 16 June 2023
  • #REDIRECT [[Insulation Joints and Overlay]]
    43 bytes (5 words) - 18:19, 25 November 2015
  • ...ts and Overlay|<i class="fa fa-hand-o-right" aria-hidden="true"></i> <big>Insulation Joints and Overlay Boards</big>]]
    2 KB (290 words) - 20:13, 22 August 2016
  • ...heir protective surfacing will allow many minor anomalies, such as deck or insulation unevenness, to readily telescope through to the roof surface. Over time, d
    22 KB (3,281 words) - 21:46, 17 July 2017
  • ...tyrene insulation board can be installed in thicknesses necessary for high insulation values and in a stair stepped fashion, facilitating a positive slope to dra :Poured 25 mm (1") for NVS and 50 mm (2") for Insulcel thickness over EPS insulation, these LWIC systems have been engineered for use over non-slotted or slotte
    3 KB (474 words) - 21:16, 12 February 2019
  • || Siplast || Siplast SBS Para-Stik Insulation Adhesive || style="text-align:center;"| '''TDS''' || style="text-align:cent || Siplast || Siplast SBS Parafast Insulation Adhesive C Part 1 || style="text-align:center;"| '''TDS''' || style="text-a
    17 KB (2,334 words) - 18:57, 14 September 2017
  • ::[[BUR Roof Systems Standard#BURINSULATION |7 INSULATION]] ::[[BUR Roof Systems Standard#BURINSULATIONOVERLAY |8 INSULATION OVERLAY BOARD]]
    2 KB (209 words) - 21:11, 30 August 2021
  • ;Accepted for application in: Waterproofing Systems (roofs)(high-density insulation overlay)<br>Water-shedding Systems (ASM and Asphalt Shingles) :*is a rigid roof insulation boards comprised of a high-density closed cell polyisocyanurate fo
    1 KB (196 words) - 15:40, 27 October 2020
  • ;Accepted for application in: Waterproofing Systems (roofs)(high-density insulation overlay)<br>Water-shedding Systems (ASM and Asphalt Shingles) :*is a rigid roof insulation boards comprised of a high-density closed cell polyisocyanurate fo
    1 KB (196 words) - 15:42, 27 October 2020
  • ...ng system'' is defined by whatever is placed on the membrane, which may be insulation, ballast, pavers or overburden. These materials will displace water and th ...e roof membrane, while retaining existing ''roof system'' components (i.e. insulation, ballast).
    30 KB (4,336 words) - 21:13, 18 August 2021
  • ...g applications, accepted by the '''''RoofStar Guarantee Program''''' as an insulation overlay board.
    1 KB (148 words) - 21:40, 13 November 2020
  • |+ XPS Insulation<br><small>Click on a manufacturer's name to see the full list of their prod
    6 KB (593 words) - 22:15, 21 September 2023
  • ====Insulation==== ====Insulation Overlay Panels====
    3 KB (432 words) - 21:52, 28 March 2024
  • ...verlay boards (minimum thickness 4.5 mm (3/16") nominal) or insulation and insulation overlay boards specifically designed for torch applications''' - mechanical
    14 KB (2,091 words) - 22:59, 9 November 2018
  • ...tion of, a roof or waterproofing membrane assembly. This excludes thermal insulation but includes, and is not limited to, || 2018-January-25 }} ...oot intrusion barrier, and drainage layer. Tightly butt all protection and insulation boards, overlap all filter mat seams and seal all laps of roof intrusion ba
    21 KB (2,722 words) - 14:55, 25 September 2017
  • ...tion of, a roof or waterproofing membrane assembly. This excludes thermal insulation but includes, and is not limited to, || 2018-January-25 }} ...oot intrusion barrier, and drainage layer. Tightly butt all protection and insulation boards, overlap all filter mat seams and seal all laps of roof intrusion ba
    21 KB (2,856 words) - 22:57, 9 November 2018
  • Only RoofStar-accepted insulation materials, specifically listed by membrane manufacturers in this Manual as ...be installed under two (2) offset / staggered layers of RoofStar-accepted insulation overlay boards.
    14 KB (2,160 words) - 15:21, 29 September 2016
  • ...ched) roofing membranes that are adhered directly to concrete decks unless insulation is installed directly above or over the membrane. ...tened insulation, the gypsum board must be fastened independently from the insulation. The minimum number of fasteners(screws or screws and plate) is four (4) pe
    5 KB (815 words) - 16:33, 29 September 2016
  • ...ight, and free of "humps" or depressions. These can counteract any sloped insulation systems installed by the roofing contractor and cause ponding. On new cons ...vel in the roof deck are less than the percentage of slope provided by the insulation.</span> <span class="recommended">A minimum slope of 1:50 (1/4" in 12") is
    20 KB (3,072 words) - 15:18, 15 January 2019
  • ...polystyrene with square edges, suitable for heavy loads. '''Sopra-XPS''' insulation is used in Protected Membrane Roof Assemblies and on plaza decks.
    1 KB (152 words) - 22:29, 31 January 2019
  • ...polystyrene with square edges, suitable for heavy loads. '''Sopra-XPS''' insulation is used in Protected Membrane Roof Assemblies and on plaza decks.
    1 KB (155 words) - 22:31, 31 January 2019
  • *Insulation (board or panel; tapered) *Insulation overlay board
    22 KB (3,050 words) - 16:20, 12 December 2023
  • * Use a protective base sheet on all wood decks and over ignitable insulation, can strips or other flammable surfaces. ...all ignitable insulation surfaces, edges and over all joints between rigid insulation boards. The base ply provides a protective covering for underlying ignitab
    14 KB (2,333 words) - 16:39, 9 February 2022
  • .../index.php?title=Standard_for_SBS-Modified_Bitumen_Membrane_Systems#PART_7 Insulation]=== :<big><big>Composite Board Insulation</big></big>
    6 KB (742 words) - 20:36, 27 July 2021
  • |+ EPS Insulation<br><small>Click on a manufacturer's name to see the full list of their prod ...| Plasti-Fab]]''' || [[Materials:Plastispan Insulation (Type 1)|Plastispan Insulation (Type 1)]] || style="text-align:center;"| ‒ || style="text-align:center;"
    7 KB (630 words) - 17:46, 24 June 2022
  • ====Insulation====
    2 KB (242 words) - 20:44, 8 June 2023
  • | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]
    416 KB (56,532 words) - 22:23, 5 April 2024
  • | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]
    424 KB (57,418 words) - 22:20, 5 April 2024
  • | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]
    421 KB (57,062 words) - 22:20, 5 April 2024
  • | [[#PART_7 | Part 7 - Insulation]] | [[#PART_8 | Part 8 - Insulation Overlays]]
    296 KB (41,811 words) - 22:23, 5 April 2024
  • ...="1" rowspan="2" style="vertical-align:center;text-align:center;" | <small>Insulation<br>Overlay </small> ...="1" rowspan="2" style="vertical-align:center;text-align:center;" | <small>Insulation </small>
    5 KB (558 words) - 14:26, 7 April 2020
  • ...n flat or low-slope roofing. It can be installed over word decks or rigid insulation as an overlay board.</td>
    2 KB (285 words) - 20:47, 26 August 2021
  • <big><big>'''Secondary Materials: Insulation & Overlays'''</big></big> ...s - Insulation (Waterproofing Systems) | <i class="fa fa-caret-right"></i> Insulation]]</big>
    13 KB (1,636 words) - 17:02, 5 January 2024
  • ...ight, and free of "humps" or depressions. These can counteract any sloped insulation systems installed by the roofing contractor and cause ponding. On new cons ...vel in the roof deck are less than the percentage of slope provided by the insulation. A minimum slope of 1:50 (1/4" in 12") is strongly recommended. The except
    20 KB (2,969 words) - 16:06, 9 September 2021
  • ...he membrane, or as a thermal barrier between the roof deck and combustible insulation.
    1 KB (198 words) - 15:33, 9 September 2021
  • ...testing is specified, testing shall be conducted prior to installation of insulation and roof coverings, and must be performed to ''ASTM D5957''.
    11 KB (1,608 words) - 22:03, 3 May 2021
  • | Part 7 || '''Insulation''' | Part 8 || '''Insulation Overlays''' (Eave protection, Underlayments, and ventilation, in the Standa
    15 KB (2,132 words) - 19:02, 18 August 2023
  • [[File:Low-slope Roof Insulation.jpg|300 px]] ...ctions. As part of the roof assembly, properly designed and installed roof insulation provides the following benefits:
    23 KB (3,279 words) - 15:42, 9 September 2021
  • |+ "Polyiso" Insulation<br><small>Click on a manufacturer's name to see the full list of their prod ...| style="text-align:left;"| [[Materials:SecurShield RapidLock (RL) Polyiso Insulation | {{hilite | SecurShield RapidLock (RL) Polyiso || 2024-October-20 }}]] ||
    7 KB (675 words) - 16:30, 31 October 2023
  • ...layer in reroofing and in new construction as a top layer in a multi-layer insulation system. :Retro-Fit Board Insulation / Overlay
    3 KB (393 words) - 22:01, 3 November 2016
  • ...ntegral component of the roof system, providing a protective layer for the insulation, while working with the membrane above to ensure maximum performance and lo
    6 KB (890 words) - 22:10, 3 November 2016
  • ;'''Product Summary''': Securtorch is a safe and unique fireboard roofing insulation coated with a thick layer of asphalt covered with a thermofusible protectiv
    4 KB (512 words) - 22:23, 3 November 2016
  • ...he membrane, or as a thermal barrier between the roof deck and combustible insulation.</p> ...ched) roofing membranes that are adhered directly to concrete decks unless insulation is installed directly above or over the membrane.
    5 KB (701 words) - 20:29, 24 October 2017
  • Refer to the '''Insulation''' or '''Membrane''' Manufacturer's specifications.
    227 bytes (26 words) - 13:51, 27 July 2021
  • ...terproofing membranes, testing shall be conducted prior to installation of insulation and overburdens and be performed to ASTM D5957 - 98.
    2 KB (249 words) - 22:45, 9 November 2016
  • ...ed from fluorocarbon vapour trapped in the foam's cells. Polyurethane roof insulation boards are generally available in either: ...r (such as gypsum board) should be installed between the roof deck and the insulation.
    3 KB (429 words) - 16:03, 29 September 2016
  • <big><big><big><big><big>Roofs: Insulation</big></big></big></big></big> ===Heat-resistant Insulation===
    3 KB (377 words) - 21:49, 7 September 2021
  • <big><big><big><big><big>Insulation Joints and Overlays</big></big></big></big></big> Insulation overlays are used to separate the roof membrane from the primary insulation, usually for one of two reasons:
    4 KB (532 words) - 15:44, 9 September 2021
  • ;(6) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua
    3 KB (360 words) - 18:16, 27 October 2023
  • ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in Division C of this ''Manual''.
    2 KB (262 words) - 18:33, 27 June 2022
  • ...[[SBS Roof Systems Standard#PART_7|'''Insulation - XPS''']]: See available insulation products in Division C of this ''Manual''.
    2 KB (284 words) - 18:34, 27 June 2022
  • ...ed. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Division C | Division C]] of this Manual.
    3 KB (429 words) - 21:34, 27 June 2022
  • ...Standard#PART_5|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...ed. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Division C | Division C]] of this Manual.
    3 KB (367 words) - 21:52, 27 June 2022
  • ...s#EPDMSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (351 words) - 16:48, 23 October 2017
  • ...s#EPDMSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (347 words) - 16:48, 23 October 2017
  • ...s#EPDMSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (332 words) - 16:49, 23 October 2017
  • ...s#EPDMSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (334 words) - 18:30, 23 October 2017
  • <td colspan=2>PERMA-BOARD is designed to be used as an overlay to insulation and as a base for modified, built-up and single ply membranes. Elastomeric
    3 KB (361 words) - 22:21, 3 November 2016
  • <big><big><big><big><big>Roofs: Insulation Joint Tape</big></big></big></big></big> <big><big>[[Insulation Joints and Overlay|Insulation Joint Tape]]</big></big>
    960 bytes (129 words) - 21:48, 7 September 2021
  • ...materials due to thermal and moisture variations. Traditionally, the roof insulation and roofing are secured to the roof deck by means of mechanical fastening, '''''RoofStar Guarantee Standards''''' requires mechanical fastening of the insulation wherever practical. Over concrete and other non-nailable decks, or where me
    7 KB (999 words) - 15:42, 9 September 2021
  • ...tables specified minimum thermal resistance values, depending on where the insulation was installed, but these requirements were not integrated with the design a
    21 KB (3,118 words) - 16:32, 16 March 2023
  • ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(3) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Where required.
    3 KB (440 words) - 18:14, 27 October 2023
  • ;(2) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(3) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Where required.
    3 KB (420 words) - 18:15, 27 October 2023
  • ...existing coal tar pitch roofs. In these cases a separation layer, such as insulation board, is often used to prevent the asphalt system from contacting any trac | Insulation || +204°C (+400°F) to +149°C (+300°F) || 16 Seconds
    15 KB (2,293 words) - 15:33, 9 September 2021
  • ...re the insulation is above the membrane, the gravel is used to protect the insulation from ultraviolet rays, wind uplift, and flotation. For ballast and securem
    8 KB (1,280 words) - 16:25, 9 September 2021
  • ...#8220;conventional&#8221; roof assembly the roof membrane is on top of the insulation where it is subject to many life-shortening elements, and it must function ...roduce a problem with vapour trapped within the assembly. This can lead to insulation and roof membrane deterioration and, eventually, roof failure.
    11 KB (1,624 words) - 16:21, 9 September 2021
  • ...h living space condenses in the attic, producing moisture on wood framing, insulation and roofing. || [[File:Roofventcold.gif]] || Proper ventilation allows mois ...all be designed to prevent the entry of rain, snow and insects. || Ceiling insulation shall not be installed in a manner that will restrict free flow of air thou
    6 KB (911 words) - 15:33, 9 September 2021
  • ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual. ...yed (3A: 2- part low rising insulation adhesive, specifically used to bond insulation and cover boards)
    4 KB (462 words) - 17:01, 23 October 2017
  • ...ts. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Division C | Division C]] of this Manual.
    2 KB (281 words) - 21:53, 27 June 2022
  • ...ed. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Division C | Division C]] of this Manual.
    3 KB (422 words) - 21:33, 27 June 2022
  • ...es#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (382 words) - 17:02, 23 October 2017
  • ...es#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (360 words) - 17:01, 23 October 2017
  • ...es#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (374 words) - 17:02, 23 October 2017
  • ...es#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (373 words) - 17:02, 23 October 2017
  • ...lso Accepted Roof Deck Insulation products by clicking on this [[Roof Deck Insulation|link]]. :{{Template:Insulation (Polyiso)}}
    146 bytes (19 words) - 17:16, 17 June 2016
  • ====Insulation Overlay Panels==== ====Insulation Overlay Panels====
    4 KB (466 words) - 22:03, 23 October 2023
  • ====Insulation Overlay Panels==== ====Insulation Overlay Panels====
    3 KB (409 words) - 14:16, 8 June 2023
  • ...and a water-resistant treated core, and is an accepted deck overlay and an insulation overlay board in the '''''RoofStar Guarantee Program'''''.
    1 KB (165 words) - 14:34, 14 April 2020
  • ...g Roof System (typically ASM) to separate the roof panels from the primary insulation, and to provide a flat, firm surface for the installation of panel clips (u For more information about the use of insulation overlays in a Water-shedding Roof System, consult the specific roof system
    1 KB (185 words) - 14:15, 27 July 2021
  • ===Heat-resistant Insulation=== {{Template:Materials - Insulation (Polyisocyanurate)}}
    2 KB (251 words) - 14:13, 27 July 2021
  • {{Template:Materials - Insulation (XPS)}}
    485 bytes (56 words) - 14:10, 27 July 2021
  • ...oof Systems Standard#PART_5|'''Supporting Deck Overlay''']]: Required when insulation is too thin to span flutes of steel decking or when required as thermal bar ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in the[[Division C| Accepted Materials]] Division of this ''Manual
    4 KB (607 words) - 18:19, 27 October 2023
  • ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: Installed in staggered and offset layers, and secured in accordance w ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Subject to the requirements of '''Part 8''' in the '''''RoofS
    4 KB (630 words) - 18:16, 27 October 2023
  • ...oof Systems Standard#PART_5|'''Supporting Deck Overlay''']]: Required when insulation is too thin to span flutes of steel decking or when required as thermal bar ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua
    3 KB (420 words) - 18:14, 27 October 2023
  • ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: Installed in staggered and offset layers (not illustrated), and secur ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Subject to the requirements of '''Part 8''' in the '''''RoofS
    3 KB (474 words) - 18:18, 27 October 2023
  • ;(2) '''Insulation Overlay Protection''': Recommended. ;(5) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMINS |'''Insulation''']]: Installed between &#8216;Z&#8217; bars or wood battens on 600 mm (24
    2 KB (291 words) - 16:27, 26 April 2019
  • ;(3) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Installed with offset side and end joints. ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material (see [http://rpm.rcabc.org/index.php?
    4 KB (540 words) - 17:25, 28 June 2022
  • ;(2) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Offset and stagger layers 300 mm (12"). ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material (see [http://rpm.rcabc.org/index.php?
    3 KB (432 words) - 19:00, 28 June 2022
  • ;(3) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Offset and stagger layers 300 mm (12"). ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material.
    4 KB (537 words) - 17:35, 17 March 2023
  • ;(2) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Offset and stagger layers 300 mm (12"). ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels/ventilation material (see [http://rpm.rcabc.org/index.php?
    4 KB (530 words) - 20:11, 28 June 2022
  • ...ctural Sheet Metal Roof Systems. The material must be located between the insulation and metal panels (see [http://rpm.rcabc.org/index.php?title=RoofStar_Guaran
    3 KB (430 words) - 16:23, 28 June 2022
  • ;(4) [[ASM Roof Systems Standard#PART_7|'''Insulation''']]: Tapered to support gutter membrane, which is tied into underlayment, ...ART_7| '''Upper insulation''']]: Tapered at lower edge to conform to lower insulation slope. All flat panels must be offset and stagger layers 300 mm (12").
    5 KB (611 words) - 18:17, 12 March 2024
  • ...oof system specifications. In addition, approved proprietary underlayment, insulation overlays and metal panel separation sheets must be installed and comply to (2) <b>Ice Dam Protection / Insulation Overlay: </b>For slopes 2:12 to 4:12 use RGC accepted self-adhered modified
    3 KB (421 words) - 22:51, 21 December 2015
  • ...Standard#PART_5|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
    3 KB (383 words) - 21:38, 27 June 2022
  • ;(5) [[Grade-level Waterproofing Standard#WPINSULATION | '''Insulation''']]: Optional: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, co
    4 KB (527 words) - 21:15, 7 September 2021
  • ;(6) [[Grade-level Waterproofing Standard#WPINSULATION | '''Insulation''']]: Optional: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, co ...]: Synthetic permeable fabric required over extruded, expanded polystyrene insulation overburdened with pavers, growing mediums, sand and gravel beds for unit ma
    4 KB (527 words) - 21:16, 7 September 2021
  • ...oofing Standard#WPDECK | '''Plaza Deck Assembly''']]: Extruded polystyrene insulation and filter mat (optional) over primary waterproofing membrane. Concrete pav
    5 KB (580 words) - 21:16, 7 September 2021
  • ;(3) [[Grade-level Waterproofing Standard#WPINSULATION | '''Insulation''']]: Extruded, Expanded Polystyrene, Type 4, CAN/ULC-S701-97, compressive ;(B) Supporting Curb: Height varies depending on the insulation thickness and type of waterproofing assembly.
    4 KB (596 words) - 21:17, 7 September 2021
  • ...ng Standard#WPINSULATION | '''Insulation''']]: Type 4 extruded polystyrene insulation ...paver pedestals designed to carry predicted live loads and accepted by the insulation manufacturer.
    3 KB (413 words) - 21:22, 7 September 2021
  • ;(2) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: Installed in staggered and offset layers (not illustrated), and secur ;(3) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Subject to the requirements of Part 8 in the Standard.
    3 KB (472 words) - 17:57, 27 October 2023
  • ;(2) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: Installed in staggered and offset layers (not illustrated), and secur ;(3) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Subject to the requirements of '''Part 8''' in the '''''RoofS
    3 KB (446 words) - 17:36, 27 October 2023
  • ...('''5''')('''4'''). In all other cases, a second drainage layer above the insulation is discretionary). Turn the drainage layer up at the perimeter to convey w ;(6) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: XPS insulation, ideally installed in multiple layers that are offset and staggered as illu
    5 KB (661 words) - 17:37, 27 October 2023
  • ;(7) '''Plaza Deck / Planter Interior Assembly''': Extruded polystyrene insulation and filter mat over primary roof membranes. Concrete pavers placed above pr
    4 KB (513 words) - 18:21, 27 October 2023
  • * Insulation to replace any wet materials discovered in cuts ...entrapped air or water, usually over decks with concrete fills or with wet insulation.</td>
    75 KB (11,617 words) - 21:00, 3 September 2021
  • ...roofing materials and components, such as single-ply membranes, flashings, insulation boards, etc. Before adhesives are applied, their compatibility with other :Applying hot asphalt to what will be the concealed side of a material (insulation sheet, felt, etc.) before turning it over and arranging it in place.
    76 KB (11,565 words) - 18:09, 26 January 2024
  • <u>RSI - Roofing / Siding / Insulation</u>. 7500 Old Oak Boulevard, Cleveland, OH 44130.
    4 KB (548 words) - 14:32, 18 August 2023
  • ===[[RoofStar Guarantee Standards for EPDM Membrane Systems#EPDMINSULATION | Insulation]] === :<big><big>Composite Board Insulation</big></big>
    5 KB (633 words) - 20:30, 26 July 2021
  • ===[[RoofStar Guarantee Standards for TPO Membrane Systems#TPOINSULATION | Insulation]]=== :<big><big>Composite Board Insulation</big></big>
    5 KB (614 words) - 20:30, 26 July 2021
  • ...php?title=RoofStar_Guarantee_Standards_for_ASM_Roof_Assemblies#ASMINS '''5 Insulation'''] and [http://rpm.rcabc.org/index.php?title=RoofStar_Guarantee_Standards_
    4 KB (582 words) - 21:35, 30 October 2017
  • ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:
    4 KB (584 words) - 15:27, 26 February 2024
  • ;(2) [[TPO Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[TPO Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:
    4 KB (599 words) - 22:20, 23 February 2024
  • ROOFMATE insulation is an extruded, expanded, foamed Type 4 CAN / ULC-S701-97 / CAN / CGSB-51.2
    2 KB (255 words) - 18:34, 4 December 2019
  • ...® insulation is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes FOAMULAR® C200® insulation is an extruded, Type 3 CAN / ULC S701 polystyrene foam. It has excellent in
    2 KB (252 words) - 21:36, 7 November 2016
  • FOAMULAR® F350 insulation is an extruded, Type 4 CAN/ULC-S701/CAN/CGSB-51.20-M87 polystyrene rigid bo
    2 KB (264 words) - 21:37, 7 November 2016
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes
    2 KB (269 words) - 21:57, 7 November 2016
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes
    2 KB (269 words) - 21:58, 7 November 2016
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes
    2 KB (269 words) - 21:58, 7 November 2016
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes
    3 KB (353 words) - 17:41, 13 October 2016
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes
    3 KB (353 words) - 17:42, 13 October 2016
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes
    3 KB (353 words) - 17:42, 13 October 2016
  • ...sulation that is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes
    3 KB (353 words) - 17:42, 13 October 2016
  • ...hitectural Sheet Metal panels, and may be used as a separation layer above insulation in an insulated ASM assembly.
    2 KB (292 words) - 16:25, 24 October 2023
  • ...hitectural Sheet Metal panels, and may be used as a separation layer above insulation in an insulated ASM assembly.
    2 KB (298 words) - 16:26, 24 October 2023
  • ...density mineral wool (stone wool) support panel and on a polyisocyanurate insulation board (SOPRA-ISO).
    1 KB (201 words) - 22:05, 28 June 2021
  • ...TE insulation is specifically designed to provide high quality, economical insulation for all conventional roofs, with single-ply, 2-ply or 4-ply roof membranes. DECKMATE roof insulation is an extruded, expanded Type 2 CAN / ULC-S701-97 / CAN / CGSB-51.20-M87 po
    2 KB (245 words) - 18:32, 4 December 2019
  • ...US insulation is specifically designed to provide high quality, economical insulation for conventional roofs, with single-ply, two-ply or four-ply roof membranes DECKMATE* PLUS roof insulation is an extruded, expanded, Type 3 CAN / ULC S701 polystyrene foam. It has ex
    2 KB (243 words) - 18:33, 4 December 2019
  • ROOFMATE insulation is an extruded, expanded, foamed Type 4 CAN / ULC-S701-97 / CAN / CGSB-51.2
    2 KB (255 words) - 18:33, 4 December 2019
  • ...nsulation with a nominal density approximately 100% higher than PlastiSpan insulation (Type 1) at 32 kg / m<sup>3</sup> (2.0 lb / ft<sup>3</sup>).
    1 KB (148 words) - 15:53, 2 November 2016
  • ...taper across the 1.2-rn (48") width. A predetermined layout of the tapered insulation boards is provided by Plasti-Fab in order to include a 1:50 (1/4" in 12") o ...back slopes are available; custom computerized design of PlastiSpan sloped insulation boards layout is provided..
    2 KB (230 words) - 15:53, 2 November 2016
  • ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ...adhered or mechanically fastened. Two layers required over heat-sensitive insulation.
    3 KB (416 words) - 18:00, 27 October 2023
  • ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Where required.
    3 KB (334 words) - 18:01, 27 October 2023
  • ...'''ISOGARD&#8482; HD''' Cover Board is a half-inch (12.7 mm) thick polyiso insulation designed for use as a cover board. It is a high density, closed-cell, polyi :*Keep insulation dry at all times.<br>
    3 KB (454 words) - 21:48, 13 November 2020
  • ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']] ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: As required.
    3 KB (374 words) - 17:46, 27 October 2023
  • ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: As required.
    4 KB (474 words) - 17:59, 27 October 2023
  • ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]:
    3 KB (402 words) - 17:50, 27 October 2023
  • ;(2) [[EPDM Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[EPDM Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:
    4 KB (580 words) - 16:27, 26 February 2024
  • ...lashing must be 200mm (8") in height above the top of extruded polystyrene insulation or protection/drainage layer, extended under the window mullion (fenestrati ...[[SBS Roof Systems Standard#PART_11|'''Protection/Drainage Layer''']] '''- Insulation Surfacing''': Assemblies to be determined by Design Authority. Paver system
    4 KB (508 words) - 18:51, 27 June 2022
  • ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C|'''Accepted Materials''']] section of this Man ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: Where required.
    3 KB (386 words) - 21:52, 16 September 2022
  • ...r glass board insulation complying to ASTM C552-00 <b>OR</b> mineral fiber insulation conforming to CAN / CGSB 51.31-M84 and ASTM E84.
    3 KB (360 words) - 18:52, 21 September 2022
  • ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: As required.
    3 KB (377 words) - 18:21, 27 October 2023
  • ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: As required.
    3 KB (344 words) - 18:18, 27 October 2023
  • ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in Division C of this ''Manual''. ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: As required.
    3 KB (381 words) - 18:47, 27 June 2022
  • ...Standard#PART_7|'''Insulation''']]: Mechanically fastened. See available insulation products in the [[Division C| Accepted Materials]] Division of this ''Manua ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]:
    3 KB (418 words) - 18:15, 27 October 2023
  • ===[[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMINS | Insulation]] === :<big><big>Composite Board Insulation</big></big>
    5 KB (576 words) - 20:33, 26 July 2021
  • ...om 24 gauge. The panel can be applied on to solid sheeting with or without insulation. Width from 300 mm (12") to 400 mm (16") wide with a 22 mm (1") height at t
    5 KB (640 words) - 17:15, 26 October 2023
  • ...of 24 gauge. The panel can be applied onto solid sheeting with or without insulation. Width from is 12" to 20", with a 1" height at the male rib. Panels are con
    5 KB (721 words) - 17:16, 26 October 2023
  • ...rom 24 gauge. The panel can be applied onto solid sheeting with or without insulation. Width from 300 mm (12") to 500 mm (20") wide with a 25 mm (1") height at t ...of application''': on wood or metal sloped roofs, with or without exterior insulation; in commercial, institutional, industrial and residential construction; als
    5 KB (681 words) - 17:22, 26 October 2023
  • ...of application''': on wood or metal sloped roofs with or without exterior insulation; in commercial, institutional, industrial and residential construction; for
    4 KB (566 words) - 17:22, 26 October 2023
  • ...of application''': on wood or metal sloped roofs with or without exterior insulation; in commercial, institutional, industrial and residential construction; for
    4 KB (557 words) - 17:23, 26 October 2023
  • ...of application''': on wood or metal sloped roofs with or without exterior insulation; in commercial, institutional, industrial and residential construction; for
    4 KB (582 words) - 17:22, 26 October 2023
  • ...om 24 gauge. The panel can be applied on to solid sheeting with or without insulation. Width from 300 mm (12") to 500 mm (20") wide with a 25 mm (1") height at t
    4 KB (533 words) - 17:28, 26 October 2023
  • ! XPS Insulation<br>Thickness !! Stone Ballast Required Weight !! Ballast Depth<br>(approxim | Insulation || #12 || 73.03 mm (2-7/8”) Hexagonal, 76.2 mm (3”) Round or Square
    55 KB (7,359 words) - 21:22, 3 October 2023
  • ...in both new and re-roof applications as a primary insulation or an overlay insulation. Toprock Stone wool contributes significant advantages to long term perform ...ied, hot applied or cold applied adhered membrane assemblies direct to the insulation without the use of a coverboard.
    3 KB (468 words) - 19:39, 13 November 2020
  • ...tyrene insulation board can be installed in thicknesses necessary for high insulation values and in a stair stepped fashion, facilitating a positive slope to dra :Poured 25 mm (1") for NVS and 50 mm (2") for Insulcel thickness over EPS insulation, these LWIC systems have been engineered for use over non-slotted or slotte
    3 KB (476 words) - 22:12, 2 November 2016
  • ...tyrene insulation board can be installed in thicknesses necessary for high insulation values and in a stair stepped fashion, facilitating a positive slope to dra Poured 25 mm (1") for NVS and 50 mm (2") for Insulcel thickness over EPS insulation, these LWIC systems have been engineered for use over non-slotted or slotte
    3 KB (437 words) - 21:22, 13 October 2016
  • ...in both new and re-roof applications as a primary insulation or an overlay insulation. Soprarock Stone wool contributes significant advantages to long term perfo ...ied, hot applied or cold applied adhered membrane assemblies direct to the insulation without the use of a coverboard.
    3 KB (463 words) - 21:48, 28 March 2024
  • ...in both new and re-roof applications as a primary insulation or an overlay insulation. Soprarock Stone wool contributes significant advantages to long term perfo ...ied, hot applied or cold applied adhered membrane assemblies direct to the insulation without the use of a coverboard.
    3 KB (465 words) - 21:49, 28 March 2024
  • ...in both new and re-roof applications as a primary insulation or an overlay insulation. Toprock Stone wool contributes significant advantages to long term perform ...ied, hot applied or cold applied adhered membrane assemblies direct to the insulation without the use of a coverboard.
    3 KB (468 words) - 19:39, 13 November 2020
  • <td colspan=3>Fesco Board is a rigid, thermal roof insulation for use in built-up, modified bitumen and some single ply roofing systems.
    4 KB (508 words) - 21:50, 3 November 2016
  • ...nd easy to handle. It has a high thermal R-value that provides outstanding insulation protection, which helps to reduce heating and cooling costs.
    3 KB (431 words) - 23:33, 24 February 2023
  • ...le Corporation manufactures a variety of polyisocyanurate insulations. The insulation panels are manufactured with flexible facers, trilaminate foil, glassmat, o :ENRGY 3 CGF identifies the most widely used insulation using HCFC 141.b in the family of products manufactured by Johns Manville C
    3 KB (408 words) - 21:32, 3 November 2016
  • ...ll polyisocyanurate foam insulation product that provides superior R value insulation characteristics and fire resistance. '''Paratherm's''' coated facer is suit
    2 KB (297 words) - 21:47, 13 November 2020
  • ...safe procedures. Polyisocyanurate, the most widely used and accepted foam insulation product in use today, provides superior fire performance characteristics an
    3 KB (494 words) - 14:22, 15 September 2017
  • ...roduct Summary''': '''SecurShield HD Polyiso Insulation''' is a rigid roof insulation panel composed of a high-density, closed-cell polyisocyanurate foam core la ...s HD is a 12.7 mm (1/2") thick high density, closed-cell, polyisocyanurate insulation cover board. SecurShield HD Plus is ideal for use with all Carlisle mechan
    4 KB (639 words) - 20:54, 9 April 2020
  • ...nts an improvement to the product; Resista was rated as a Type 1 "Polyiso" insulation (compressive strength: 138 kPa), while ISOGARD CG can now be classified as
    2 KB (298 words) - 21:03, 19 June 2023
  • ...ximum thermal efficiency. Hunter Panels Polyisocyanurate '''H-Shield CG''' insulation is UL and FM approved as a system component in certain roofing assemblies.
    2 KB (220 words) - 18:51, 28 June 2021
  • ...ct Summary: Polyisocyanurate '''H-Shield CG''' is a high-density foam core insulation overlay board covered on both sides with a medium weight fiber-glass reinfo
    1 KB (170 words) - 18:55, 28 June 2021
  • ...thermal efficiency. Hunter Panels Polyisocyanurate '''H-Shield Premier''' insulation is UL and FM approved as a system component in certain roofing assemblies.
    3 KB (395 words) - 21:47, 3 November 2016
  • ...hermal efficiency. Hunter Panels Polyisocyanurate '''H-Shield Composite''' insulation is UL and FM approved as a system component in certain roofing assemblies.
    3 KB (395 words) - 21:48, 3 November 2016
  • ...ell, rigid foam insulation material containing air as main ingredient. EPS insulation resists moisture, mold, and fungi with low environmental impacts, high & st
    1 KB (186 words) - 16:37, 16 June 2020
  • ...ell, rigid foam insulation material containing air as main ingredient. EPS insulation resists moisture, mold, and fungi with low environmental impacts, high & st :'''Korolite 100''' Type 1 EPS insulation is available in various lengths, widths and common thicknesses; refer to th
    2 KB (220 words) - 16:55, 16 June 2020
  • ...variety of roof systems, supplied in both flat and sloped profiles. These insulation materials are closed cell, light weight and, because of their unique cellul <u>KOROLITE REGULAR INSULATION</u>
    1 KB (200 words) - 22:51, 28 May 2020
  • ...ell, rigid foam insulation material containing air as main ingredient. EPS insulation resists moisture, mold, and fungi with low environmental impacts, high & st :'''Korolite 160''' Type 2 EPS insulation is available in various lengths, widths and common thicknesses; refer to th
    2 KB (222 words) - 16:55, 16 June 2020
  • ...mmary''': PlastiSpan insulation identifies the most widely used PlastiSpan insulation in the family with a nominal density of 16 kg / m3 (1.0 lb / ft3). It provi
    1 KB (154 words) - 15:52, 2 November 2016
  • ...insulation with a normal density approximately 50% higher than PlastiSpan insulation (Type 1) at 24 kg / m<sup>3</sup> (1.5 lb / ft<sup>3</sup>).
    1 KB (148 words) - 15:52, 2 November 2016
  • ...nel. The panel can be applied to solid wood or steel decks with or without insulation. The panel can be supplied with or without 6mm (1/4") x 18 mm (3/4") screw ...tion to water penetration, internal condensation, air and vapour barriers, insulation design and collateral material selection.
    8 KB (1,154 words) - 15:45, 5 January 2016
  • ...pm.rcabc.org/index.php?title=SBS_Roof_Systems_Standard#PART_7 {{hilite | 7 INSULATION || 2020-October-21 }}] ...pm.rcabc.org/index.php?title=SBS_Roof_Systems_Standard#PART_8 {{hilite | 8 INSULATION OVERLAYS || 2020-October-21 }}]
    3 KB (366 words) - 18:42, 30 August 2021
  • ::[http://rpm.rcabc.org/index.php?title=EPDM_Roof_Systems_Standard#PART_7 7 INSULATION] ...m.rcabc.org/index.php?title=EPDM_Roof_Systems_Standard#PART_8 {{hilite | 8 INSULATION OVERLAYS|| 2021-February-7 }}]
    2 KB (343 words) - 18:18, 31 August 2021
  • ::[http://rpm.rcabc.org/index.php?title=TPO_Roof_Systems_Standard#PART_7 7 INSULATION] ...pm.rcabc.org/index.php?title=TPO_Roof_Systems_Standard#PART_8 {{hilite | 8 INSULATION OVERLAYS|| 2021-February-7 }}]
    2 KB (335 words) - 18:43, 30 August 2021
  • ...c.org/index.php?title=ASM_Roof_Systems_Standard#ASMINSULATION {{hilite | 7 INSULATION || 2019-November-9 }}]
    3 KB (338 words) - 16:00, 2 September 2021
  • ...cabc.org/index.php?title=Asphalt_Shingle_Systems_Standard#AShINSULATION 7 INSULATION]
    2 KB (317 words) - 16:03, 31 August 2021
  • ::[http://rpm.rcabc.org/index.php?title=PVC_Roof_Systems_Standard#PART_7 7 INSULATION] ...pm.rcabc.org/index.php?title=PVC_Roof_Systems_Standard#PART_8 {{hilite | 8 INSULATION OVERLAYS|| 2021-February-7 }}]
    2 KB (333 words) - 20:29, 30 August 2021
  • ...ified protected membrane roofs must “kick out” minimum 50 mm (2") over insulation and filter fabric. (see [[SBS Details:D1.7.2 Assemblies (Protected Membrane
    12 KB (1,696 words) - 22:01, 7 March 2018
  • ...ons or alternatively, when pipes are irregular in size spray foam urethane insulation may be used to fill gaps between pipes and flashings. Strip-in type roof pe
    12 KB (1,802 words) - 15:50, 30 March 2017
  • ...g applications, accepted by the '''''RoofStar Guarantee Program''''' as an insulation overlay board.
    1 KB (144 words) - 21:40, 13 November 2020
  • :#Only RoofStar-accepted insulation, specifically listed by membrane manufacturers in the RPM as acceptable for ...ns are used in a roof assembly, they must be covered with a heat-resistant insulation at least 50 mm (2") thick. || 2019-February-16 }}
    18 KB (2,588 words) - 17:28, 13 March 2018
  • ====Insulation==== :[[Materials:SecurShield RapidLock (RL) Polyiso Insulation | {{hilite | SecurShield RapidLock (RL) Polyiso || 2024-October-20 }}]]
    4 KB (472 words) - 16:22, 31 October 2023
  • ====Insulation====
    2 KB (277 words) - 17:18, 8 June 2023
  • RoofStar-accepted insulation overlay boards shall be installed over all plastic foam insulations (EPS, X ...gered 300 mm (12") from adjacent layers and rows. The uppermost layer of [insulation or] overlay board directly below membranes shall have joints that are offse
    8 KB (1,100 words) - 17:05, 22 August 2017
  • ====Insulation==== ====Insulation====
    2 KB (328 words) - 17:43, 28 February 2024
  • ...ns or alternatively, when pipes are irregular in size, spray foam urethane insulation may be used to fill gaps between pipes and flashings. Strip-in type roof pe
    14 KB (1,967 words) - 22:58, 9 November 2018
  • ...he membrane, or as a thermal barrier between the roof deck and combustible insulation.</div> ...ched) roofing membranes that are adhered directly to concrete decks unless insulation is installed directly above or over the membrane.
    5 KB (779 words) - 20:28, 24 October 2017
  • ...ified protected membrane roofs must “kick out” minimum 50 mm (2") over insulation and filter fabric. (see [[SBS Details:D1.7.1-2 Assemblies (Protected Membra
    10 KB (1,482 words) - 22:00, 7 March 2018
  • RoofStar-accepted insulation overlay boards shall be installed over all plastic foam insulations (EPS, X ...gered 300 mm (12") from adjacent layers and rows. The uppermost layer of [insulation or] overlay board directly below membranes shall have joints that are offse
    8 KB (1,108 words) - 22:22, 18 October 2017
  • ...ng to CAN / CGSB-51.20-M87, Type 4) is the only commercially produced roof insulation suitable for a PMRA, providing properties such as water resistance (i.e. re ...ne as well as on top. This may offer cost savings as only the top layer of insulation requires ballast and the bottom layer (mechanically-fastened or adhered) ne
    9 KB (1,317 words) - 14:38, 24 August 2017
  • ====Insulation Overlay Panels====
    3 KB (449 words) - 14:48, 8 June 2023
  • ====Insulation==== ====Insulation Overlay Panels====
    2 KB (229 words) - 17:22, 8 June 2023
  • ====Insulation==== ====Insulation Overlay Panels====
    8 KB (993 words) - 20:26, 20 March 2024
  • ====Insulation==== :[[Materials:ENRGY 3 CGF Insulation |ENRGY 3 CGF Insulation (Flat and Tapered)]]
    3 KB (405 words) - 20:43, 8 June 2023
  • ====Insulation==== ====Insulation====
    4 KB (507 words) - 20:45, 8 June 2023
  • ====Insulation==== :[[Materials:Plastispan Insulation (Type 1)|Plastispan Insulation (Type 1)]]
    2 KB (230 words) - 20:46, 8 June 2023
  • ====Insulation Overlay Panels====
    1 KB (204 words) - 21:42, 16 October 2023
  • ====Insulation Overlay Panels====
    2 KB (213 words) - 21:32, 8 June 2023
  • ====Insulation==== :'''Mineral Fibre Insulation'''
    2 KB (280 words) - 21:51, 8 June 2023
  • ====Insulation==== ====Insulation Overlay Panels====
    11 KB (1,293 words) - 20:23, 20 March 2024
  • ==== [[Roof Deck Insulation]] ==== :'''Fibreboard Roof Insulation'''
    3 KB (319 words) - 17:34, 22 November 2016
  • ==== [[Roof Deck Insulation]] ==== :'''Tapered Insulation'''
    2 KB (254 words) - 17:18, 6 June 2016
  • ==== [[Roof Deck Insulation]] ==== :'''Tapered Insulation'''
    2 KB (254 words) - 17:18, 6 June 2016
  • ====Insulation==== ====Insulation Overlay Panels====
    6 KB (824 words) - 19:17, 1 February 2024
  • <big><big><big><big><big>Roofs: Insulation Overlays</big></big></big></big></big><br> Insulation overlays are used to separate the roof membrane from the primary insulation, usually for one of two reasons:
    3 KB (334 words) - 18:08, 16 June 2023
  • :[[Insulation Joints and Overlay|Insulation Joints and Overlay Boards]] [[Insulating the Roof|Low Slope roofs: all about insulation]]
    7 KB (990 words) - 20:54, 2 August 2016
  • Polyisocyanurate is a closed-cell rigid foam material. The insulation boards are manufactured with asphalt-saturated felt, glass fibre or acrylic Polyisocyanurate foamboard roof insulation is presently manufactured to two standards:
    3 KB (421 words) - 14:50, 4 May 2017
  • ...safe procedures. Polyisocyanurate, the most widely used and accepted foam insulation product in use today, offers fire performance characteristics and the abili
    2 KB (237 words) - 14:43, 12 June 2020
  • ...safe procedures. Polyisocyanurate, the most widely used and accepted foam insulation product in use today, provides superior fire performance characteristics an
    3 KB (494 words) - 14:20, 15 September 2017
  • ...lso Accepted Roof Deck Insulation products by clicking on this [[Roof Deck Insulation|link]]. ...ed from fluorocarbon vapour trapped in the foam's cells. Polyurethane roof insulation boards are generally available in either:
    3 KB (444 words) - 17:15, 17 June 2016
  • |+ Mineral Fibre Insulation<br><small>Click on a manufacturer's name to see the full list of their prod
    4 KB (403 words) - 17:24, 28 February 2024
  • ...lso Accepted Roof Deck Insulation products by clicking on this [[Roof Deck Insulation|link]]. ...varying from 16 to 48 kg / cu.m (1 to 3 lb / cu.ft). Expanded polystyrene insulation is commonly referred to as &#8220;beadboard&#8221; or &#8220;popcorn&#8221;
    3 KB (422 words) - 17:14, 17 June 2016
  • #Compressible insulation is to be installed between the sheathing and the wall and an accepted expan =Part 7 INSULATION=
    117 KB (13,071 words) - 18:36, 5 April 2024
  • <div class="mw-collapsible-content">{{Materials - Insulation Overlay (Asphaltic Board)}}</div> ...ndex.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPINSULATION Insulation]===
    7 KB (968 words) - 20:34, 26 July 2021
  • ...oot intrusion barrier, and drainage layer. Tightly butt all protection and insulation boards, overlap all filter mat seams and seal all laps of roof intrusion ba ...is required, testing shall be conducted prior to installation of overlying insulation or overburdens and conducted as per ASTM D5957.</div>
    7 KB (1,036 words) - 15:41, 20 July 2018
  • ...ravel ballast filter mats, and must “kick out” minimum 50 mm (2") over insulation and filter fabric.
    9 KB (1,399 words) - 22:09, 21 October 2016
  • RoofStar-accepted insulation overlay boards shall be installed over all plastic foam insulations (EPS, X ...gered 300 mm (12") from adjacent layers and rows. The uppermost layer of [insulation or] overlay board directly below membranes shall have joints that are offse
    8 KB (1,102 words) - 17:05, 22 August 2017
  • #REDIRECT [[Template:All Systems - INSULATION OVERLAY BOARD EPDM]]
    66 bytes (9 words) - 19:38, 23 January 2017
  • ...uarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual. ...yed (3A: 2- part low rising insulation adhesive, specifically used to bond insulation and cover boards)
    3 KB (439 words) - 21:37, 27 June 2022
  • ...in both new and re-roof applications as a primary insulation or an overlay insulation. Soprarock Stone wool contributes significant advantages to long term perfo ...ied, hot applied or cold applied adhered membrane assemblies direct to the insulation.
    2 KB (359 words) - 21:46, 13 November 2020
  • ...in both new and re-roof applications as a primary insulation or an overlay insulation. Soprarock Stone wool contributes significant advantages to long term perfo ...ied, hot applied or cold applied adhered membrane assemblies direct to the insulation.
    2 KB (360 words) - 21:46, 13 November 2020
  • ## <u>INSULATION</u> <td>Insulation</td>
    8 KB (1,161 words) - 14:15, 19 April 2018
  • .... ReadyFlash® features a dark coated-glass facer (CGF) on one side of the insulation board and a light coated-glass facer on the other. Utilizing the sun’s en
    2 KB (262 words) - 18:30, 28 June 2021
  • ...woven polyethylene is compatible for the use of sprayed polyurethane foam insulation. The underface is covered with a silicone release paper or film.
    2 KB (260 words) - 19:13, 28 November 2016
  • :Note that this product does not require the installation of an insulation overlay if installed according to the membrane manufacturer's published req ...to the membrane Manufacturer. Application of this base membrane on other insulation panels is permissible only under a written Variance issued by the RGC.
    2 KB (233 words) - 19:59, 27 February 2020
  • :Note that this product does not require the installation of an insulation overlay if installed according to the membrane manufacturer's published req ...to the membrane Manufacturer. Application of this base membrane on other insulation panels is permissible only under a written Variance issued by the RGC.
    2 KB (238 words) - 19:59, 27 February 2020
  • <li>accepted concrete-topped XPS insulation panels. <li>XPS insulation panels with drainage grooves or channels.
    31 KB (3,167 words) - 18:40, 12 November 2021
  • ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:
    4 KB (561 words) - 15:51, 26 February 2024
  • ;(2) [[TPO Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[TPO Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:
    4 KB (596 words) - 22:32, 23 February 2024
  • ;(2) [[SBS Roof Systems Standard#PART_7|<big>Insulation</big>]]: ;(3) [[SBS Roof Systems Standard#PART_8|<big>Insulation Overlay Panel</big>]]:
    6 KB (858 words) - 16:09, 16 February 2024
  • ...Stagger end joints of insulation a minimum of 300 mm. Mechanically fasten insulation to the deck with screws and 75 mm plates in accordance with current recomme ...m and warm the adhesive stripes. Install the sheet by rolling out onto the insulation, adhered at the striped locations. Lap side joints 76 mm and end joints 150
    22 KB (3,408 words) - 18:30, 9 November 2016
  • ...hot steep roofing asphalt; apply to any prepared roof substrate or roofing insulation suitable for hot applied roofing asphalt, or to a mechanically attached bas ...odified bitumen adhesives; apply to any prepared roof substrate or roofing insulation suitable for modified bitumen adhesives, or to a mechanically attached base
    12 KB (1,817 words) - 19:27, 7 November 2016
  • ...and its suitability to a particular slope is governed by the type of deck, insulation and fastening capability, application method, perceived stresses on the mem <u>INSULATION</u>
    14 KB (2,024 words) - 18:30, 9 November 2016
  • ...d 2-ply (or more) system on flat, curved or domed roofs over most types of insulation. ...nd its suitability for a particular slope is governed by the type of deck, insulation used, fastening capability, application method, type of finished surface of
    8 KB (1,192 words) - 19:52, 7 November 2016
  • ...and its suitability to a particular slope is governed by the type of deck, insulation and fastening capability, application method, perceived stresses on the mem <u>INSULATION</u>
    11 KB (1,543 words) - 18:21, 9 November 2016
  • ...r with 50 mm (2") side laps and 100 mm (4") end laps, adhering with Tremco Insulation Adhesive or Fas&#8217;N&#8217;Free Adhesive. <u>INSULATION</u>
    7 KB (942 words) - 20:12, 7 November 2016
  • # Do not apply roofing insulation or membrane to damp deck surface. ...) fastener per ply (including the membrane) at each insulation stop. Place insulation stops as per '''''RoofStar Guarantee Standards'''''. On non-insulated syst
    16 KB (2,588 words) - 18:14, 9 November 2016
  • ...um modified asphalt intended for use with glass felts, modified membranes, insulation and coverboards with slopes of 0:12 to 3:12 (May be suitable for other stee
    8 KB (1,205 words) - 18:26, 9 November 2016
  • # For use in &#8220;protected membrane&#8221; applications under insulation. ...mbrane combinations and their application method is governed by deck type, insulation and fastening capability, perceived stress and required finish. Please cons
    12 KB (1,673 words) - 19:42, 7 November 2016

View (previous 250 | next 250) (20 | 50 | 100 | 250 | 500)